Search NASA⌕ Search

Engineering topics

Hu, Chen

Publications and source records attributed to Hu, Chen.

At least 37 records · Page 2

From optical to X-ray ghost imaging

Recent advances in ghost imaging techniques and X-ray sources such as synchrotrons and, more recently, X-ray free-electron lasers (XFEL) have made X-ray ghost imaging a growing topic of interest. One specific type of ghost imaging utilizes thermal radiation and the measurement of intensity fluctuation correlation to form a true image without the need of a lens. This technique allows for much higher resolution than traditional X-ray imaging for a mesoscopic or even a microscopic object. In addition to this benefit of not requiring a lens, a surprising experiment has shown that, when set up correctly, this type of ghost imaging can provide clear images through the measurement of intensity fluctuation correlation when traditional images through measurements of intensity are blurred due to optical turbulence and vibrations. This turbulence-free technique will help maintain the high resolution of X-ray ghost imaging. How is an image formed from fluctuations in light? And what makes it turbulence-free? Using the concept of two-photon interference, this article provides an introduction to these fundamentally interesting concepts and X-ray ghost imaging.

ghost imaging↗

Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging

State-of-the art X-ray imaging cameras using silicon sensors for X-ray detection have demonstrated a frame-rate of 10 MHz and excellent performance for X-ray energies below 20 keV. We proposed a pixelated ultrafast inorganic scintillator-based front imager for GHz hard X-ray imaging. Here, the proposed imager is featured with a total absorption for hard X-ray photons, and provides sub-ns scintillation pulse width crucial for X-ray bunches of a few ns spacing foreseen at the proposed MaRIE facility. We measured temporal response of a dozen ultrafast and fast inorganic scintillators at the 10-ID-B site of the Advanced Photon Source (APS) of ANL. Crystal's response to hybrid X-ray beam of 30 keV, consisting of singlet bunches of 50 ps width and septuplet bunches of 27 ps width with 2.83 ns bunch spacing, was measured. Ultrafast inorganic scintillators, such as BaF 2 :Y and ZnO:Ga, show clearly resolved X-ray bunches for septuplets, as well as no degradation of amplitude for continuous eight septuplets, providing a proof of principle for the ultrafast inorganic scintillator-based total absorption front imager for the proposed MaRIE project.

47 OTHER INSTRUMENTATION↗

First experimental demonstration of time-resolved X-ray measurements with next-generation fast-timing MCP-PMT

We report the first successful time-resolved X-ray measurements at the APS 10-ID-B beamline by coupling ultrafast scintillators with photodetectors. Multiple scintillator and sensor pairs (LYSO, plastic scintillator, dynode PMTs, MCP-PMT), as well as a standalone detector (diamond), were tested to demonstrate the time-resolved measurements using hard X-rays at energies of 20 keV and above. The experimental results show that a number of choices exist for time-resolved high-energy X-ray beam measurement. Notably, by gating the photocathode, the Argonne fabricated fast-timing microchannel plate photomultiplier and LYSO crystal pair achieved fast signal detection with a rise time of 6 ns and a decay time of 33 ns. Furthermore, these experiments pave the way towards ultrafast imaging technologies using hard X-rays for many applications.

36 MATERIALS SCIENCE↗

Alkali-free Ce-doped and co-doped fluorophosphate glasses for future HEP experiments

Here we report status of alkali-free cerium-doped and co-doped fluorophosphate glasses as a potential inorganic scintillator for future high energy physics experiments. Optical and scintillation properties, such as emission, transmittance, light output, decay time and their degradation after $\gamma$-ray irradiations, are measured for glass samples produced at AFO Research Inc. Further developments are needed for this potential cost-effective glass scintillator to be used for the HHCAL detector concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of hard X-ray imaging using monolithic active pixel sensors (MAPS)

Silicon detectors have been widely used in high energy physics (HEP) experiments. The outstanding properties of silicon detectors include radiation hardness, small material budget, fine spatial resolution, high speed and low cost. In this paper, we report initial results of using a single-bit Monolithic Active Pixel Sensor (MAPS), a leading candidate for the next generation trackers in high luminosity colliders, for hard X-ray imaging. The MAPS responses to X-ray with different energies are obtained and compared with simulation. The observed cluster sizes are larger than that predicted by the Continuous Slowing Down Approximation (CSDA) model, indicating that the charge diffusion process might play an important in the MAPS response to low energy electrons. In conclusion, this work paves the way towards multiple layer ultrafast silicon sensor applications in synchrotrons and XFEL beamlines.

36 MATERIALS SCIENCE↗

A Phase 1/2 Trial of a Combination of Paclitaxel and Trastuzumab With Daily Irradiation or Paclitaxel Alone With Daily Irradiation After Transurethral Surgery for Noncystectomy Candidates With Muscle-Invasive Bladder Cancer (Trial NRG Oncology RTOG 0524)

Purpose: Bladder preservation therapy is an effective treatment for muscle-invasive urothelial carcinoma (UC). In this study we treated noncystectomy candidates with daily radiation and weekly paclitaxel for 7 weeks. Patients whose tumors showed her2/neu overexpression were additionally treated with weekly trastuzumab. Methods and Materials: Sixty-eight evaluable patients were treated with radiation therapy and either paclitaxel + trastuzumab (group 1) or paclitaxel alone (group 2). Groups were assigned on the basis of her2/neu immunohistochemistry results. Patients received 1.8-Gy fractions to a total dose of 64.8 Gy. The primary endpoint of the study was treatment-related toxicity, and secondary endpoints included complete response (CR) rate, protocol completion rate, and survival. Results: A total of 20 evaluable patients were treated in group 1 and 46 patients in group 2. Acute treatment-related adverse events (AEs) were observed in 7 of 20 patients in group 1 (35%) and 14 of 46 patients in group 2 (30.4%). Protocol therapy was completed by 60% (group 1) and 74% (group 2) of patients. Most incompletions were due to toxicity, and the majority of AEs were gastrointestinal, including 1 grade 5 AE (group 1). Two other deaths (both in group 2) were unrelated to protocol therapy. No unexpected cardiac, hematologic, or other toxicities were observed. The CR rate at 1 year was 72% for group 1 and 68% for group 2. Conclusions: In patients with muscle-invasive UC who are not candidates for cystectomy, daily radiation combined with paclitaxel is an effective treatment strategy with a high completion rate and moderate toxicity. In patients with her2/neu-positive tumors, a group generally considered to have worse outcomes, the addition of trastuzumab appears to result in comparable efficacy and toxicity. Further biomarker-driven trials should be undertaken in advancing treatment of this challenging disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the flux calibration in reverberation mapping by spectral fitting: application to the Seyfert galaxy MCG-6-30-15

We propose a method for the flux calibration of reverberation mapping spectra, based on accurate measurement of [O iii] λ5007 emission by spectral fitting. Our method can achieve better accuracy than the traditional method of Groningen and Wanders, allowing reverberation mapping measurements for objects with variability amplitudes as low as ∼5%. As a demonstration, we reanalyze the data of the Seyfert 1 galaxy MCG–6-30-15, taken from the 2008 campaign of the Lick active galactic nucleus monitoring project, which previously failed to obtain a time lag for this weakly variable object, owing to a relatively large flux calibration uncertainty. We detect a statistically significant rest-frame time lag of 6.38{sub −2.69}{sup +3.07} days between the Hβ and V-band light curves. Combining this lag with FWHM(Hβ) = 1933 ± 81 km s{sup −1} and a virial coefficient of f = 0.7, we derive a virial black hole mass of 3.26{sub −1.40}{sup +1.59}×10{sup 6} M {sub ⊙}, which agrees well with previous estimates by other methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Learning From Trials on Radiation Dose in Non-Small Cell Lung Cancer

In this issue of the International Journal of Radiation Oncology • Biology • Physics, Taylor et al present a meta-analysis of published data supporting 2 findings: (1) radiation dose escalation seems to benefit patients who receive radiation alone for non-small cell lung cancer; and (2) radiation dose escalation has a detrimental effect on overall survival in the setting of concurrent chemotherapy. The latter finding is supported by data but has perplexed the oncology community. Perhaps these findings are not perplexing at all. Perhaps it is simply another lesson in the major principle in radiation oncology, to minimize radiation dose to normal tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reverberation mapping of the broad-line region in NGC 5548: evidence for radiation pressure?

NGC 5548 is the best-observed reverberation-mapped active galactic nucleus with long-term, intensive monitoring. Here we report results from a new observational campaign between 2015 January and July. We measure the centroid time lag of the broad Hβ emission line with respect to the 5100 Å continuum and obtain τ{sub cent}=7.20{sub −0.35}{sup +1.33} days in the rest frame. This yields a black hole mass of M{sub ∙}=8.71{sub −2.61}{sup +3.21}×10{sup 7}M{sub ⊙} using a broad Hβ line dispersion of 3124 ± 302 km s{sup −1} and a virial factor of f{sub B{sub L{sub R}}}=6.3±1.5 for the broad-line region (BLR), consistent with the mass measurements from previous Hβ campaigns. The high-quality data allow us to construct a velocity-binned delay map for the broad Hβ line, which shows a symmetric response pattern around the line center, a plausible kinematic signature of virialized motion of the BLR. Combining all the available measurements of Hβ time lags and the associated mean 5100 Å luminosities over 18 campaigns between 1989 and 2015, we find that the Hβ BLR size varies with the mean optical luminosity, but, interestingly, with a possible delay of 2.35{sub −1.25}{sup +3.47} years. This delay coincides with the typical BLR dynamical timescale of NGC 5548, indicating that the BLR undergoes dynamical changes, possibly driven by radiation pressure.

79 ASTRONOMY AND ASTROPHYSICS↗

Supermassive black holes with high accretion rates in active galactic nuclei. V. A new size-luminosity scaling relation for the broad-line region

This paper reports results of the third-year campaign of monitoring super-Eddington accreting massive black holes (SEAMBHs) in active galactic nuclei (AGNs) between 2014 and 2015. Ten new targets were selected from the quasar sample of the Sloan Digital Sky Survey (SDSS), which have generally been more luminous than the SEAMBH candidates in the last two years. Hβ lags (τ{sub Hβ}) in five of the 10 quasars have been successfully measured in this monitoring season. We find that the lags are generally shorter, by large factors, than those of objects with same optical luminosity, in light of the well-known R {sub H} {sub β}–L {sub 5100} relation. The five quasars have dimensionless accretion rates of (M )-dot =10–10{sup 3}. Combining these with measurements of the previous SEAMBHs, we find that the reduction of Hβ lags depends tightly on accretion rates, τ{sub Hβ}/τ{sub R−L}∝ M-dot {sup −0.42}, where τ{sub R−L} is the Hβ lag from the normal R {sub H} {sub β}–L {sub 5100} relation. Fitting 63 mapped AGNs, we present a new scaling relation for the broad-line region: R{sub Hβ}=α{sub 1}ℓ{sub 44}{sup β{sub 1}} min [1,( M-dot / M-dot {sub c}){sup −γ{sub 1}}], where ℓ{sub 44}=L{sub 5100}/10{sup 44} erg s{sup −1} is the 5100 Å continuum luminosity, and the coefficients are α{sub 1}=29.6{sub −2.8}{sup +2.7} lt-day, β{sub 1}=0.56{sub −0.03}{sup +0.03}, γ{sub 1}=0.52{sub −0.16}{sup +0.33}, and M-dot {sub c}=11.19{sub −6.22}{sup +2.29}. This relation is applicable to AGNs over a wide range of accretion rates, from 10{sup −3} to 10{sup 3}. Implications of this new relation are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Reverberation mapping of the gamma-ray loud narrow-line Seyfert 1 galaxy 1H 0323+342

Recently, 1H 0323+342 has attracted a lot of attention as one of several narrow-line Seyfert 1 galaxies detected in the γ-ray band. To understand their central energy engines and jet phenomena, the black hole mass is important. We made use of the Lijiang 2.4 m Telescope to monitor 1H 0323+342 for more than two months. This galaxy is one of the candidates for a monitoring project of super-Eddington accreting massive black holes. The reverberation mapping shows that Hβ emission has a delayed response of 14.8{sub −2.7}{sup +3.9} days with respect to the SDSS g′ light curve in the rest frame. The optical Fe ii variations were detected after subtracting host contaminations, and a reverberation with a delay of 15.2{sub −4.1}{sup +7.4} days was found in the rest frame. By assuming the viral factor f {sub BLR} = 6.17 for the broad-line region (BLR) velocity characterized by FWHM because of the face-on orientation, we find that the black hole mass derived from Hβ is M{sub ∙}=3.4{sub −0.6}{sup +0.9}×10{sup 7}M{sub ⊙}, and the accretion rate is M-dot =1.11{sub −0.47}{sup +0.69}, where M-dot = M-dot {sub ∙}c{sup 2}/L{sub Edd}, M-dot {sub ∙} is the mass accretion rate, L {sub Edd} is the Eddington luminosity, and c is the speed of light. This black hole is one order less massive than that given by the Magorrian relation from the bulge mass. We test the relation between accretion rates and radio-loudnesses in all mapped radio-loud active galactic nuclei, and find that 1H 0323+342 falls within this group.

79 ASTRONOMY AND ASTROPHYSICS↗