Search NASASearch

Engineering topics

Hu, Yifeng

Publications and source records attributed to Hu, Yifeng.

Producing multiple chemicals through biological upcycling of waste poly(ethylene terephthalate)

Poly(ethylene terephthalate) (PET) waste is of low degradability in nature, and its mismanagement threatens numerous ecosystems. To combat the accumulation of waste PET in the biosphere, PET bio-upcycling, which integrates chemical pretreatment to produce PET-derived monomers with their microbial conversion into value-added products, has shown promise. The recently discovered Rhodococcus jostii strain PET (RPET) can metabolically degrade terephthalic acid (TPA) and ethylene glycol (EG) as sole carbon sources, and it has been developed into a microbial chassis for PET upcycling. However, the scarcity of synthetic biology tools, specifically designed for the non-model microbe RPET, limits the development of a microbial cell factory for expanding the repertoire of bioproducts from post-consumer PET. Herein, we describe the development of potent genetic tools for RPET, including (1) two inducible and titratable expression systems for tunable gene expression and (2) Serine Integrase-based Recombinational Tools (SIRT) for genome editing. Using these tools, we systematically engineer the RPET strain to ultimately establish microbial supply chains for producing multiple chemicals, including lycopene, lipids, and succinate, from post-consumer PET waste bottles, achieving the highest titer of lycopene ever reported thus far in RPET (i.e., 22.6 mg/L of lycopene, approximately 10,000-fold higher than that of the wild-type strain). Furthermore, this work highlights the great potential of plastic upcycling as a generalizable means of sustainable production of diverse chemicals.

36 MATERIALS SCIENCE

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng

System Modeling of Frost/Defrost Cycles in Heat Pumps

Accurately modeling frost/defrost cycles is crucial for guiding heat exchanger design, appropriately sizing the compressor, and quantifying seasonal energy consumption for heating. While previous modelling studies of frosting cycle have predominantly focused on the component level of fin-and-tube coils, there has been limited development of models for system defrosting cycles. This study enhances the existing knowledge by improving a detailed, segment-to-segment heat exchanger model to simulate frost/defrost cycles for both fin-and-tube coils and microchannel heat exchangers. Furthermore, it integrates this component-level model into a steady-state/quasi-steady-state system modeling framework to simulate complete frost/defrost processes, i.e. the ORNL Heat Pump Design Model (HPDM). This comprehensive approach will unveil differences in coil types, and their interactions with the outdoor fan. It will also predict energy consumption patterns and time intervals associated with these processes.

Shen, Bo