Search NASA⌕ Search

Engineering topics

Hua, Michael Yeungjun

Publications and source records attributed to Hua, Michael Yeungjun.

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗