Search NASA⌕ Search

Engineering topics

Huang, Min

Publications and source records attributed to Huang, Min.

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epitopes recognition of SARS-CoV-2 nucleocapsid RNA binding domain by human monoclonal antibodies

Coronavirus nucleocapsid protein (NP) of SARS-CoV-2 plays a central role in many functions important for virus proliferation including packaging and protecting genomic RNA. The protein shares sequence, structure, and architecture with nucleocapsid proteins from betacoronaviruses. The N-terminal domain (NP RBD ) binds RNA and the C-terminal domain is responsible for dimerization. After infection, NP is highly expressed and triggers robust host immune response. The anti-NP antibodies are not protective and not neutralizing but can effectively detect viral proliferation soon after infection. Two structures of SARS-CoV-2 NP RBD were determined providing a continuous model from residue 48 to 173, including RNA binding region and key epitopes. Five structures of NP RBD complexes with human mAbs were isolated using an antigen-bait sorting. Complexes revealed a distinct complement-determining regions and unique sets of epitope recognition. This may assist in the early detection of pathogens and designing peptide-based vaccines. Mutations that significantly increase viral load were mapped on developed, full length NP model, likely impacting interactions with host proteins and viral RNA.

59 BASIC BIOLOGICAL SCIENCES↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Profiling B cell immunodominance after SARS-CoV-2infection reveals antibody evolution to non-neutralizing viral targets

Dissecting the evolution of memory B cells (MBCs) against SARS-CoV-2 is critical for understanding antibody recall upon secondary exposure. Here, we used single-cell sequencing to profile SARS-CoV-2-reactive B cells in 38 COVID-19 patients. Using oligo-tagged antigen baits, we isolated B cells specific to the SARS-CoV-2 spike, nucleoprotein (NP), open reading frame 8 (ORF8), and endemic human coronavirus (HCoV) spike proteins. SARS-CoV-2 spike-specific cells were enriched in the memory compartment of acutely infected and convalescent patients several months post symptom onset. With severe acute infection, substantial populations of endemic HCoV-reactive antibody-secreting cells were identified and possessed highly mutated variable genes, signifying preexisting immunity. Finally, MBCs exhibited pronounced maturation to NP and ORF8 over time, especially in older patients. Monoclonal antibodies against these targets were non-neutralizing and non-protective in vivo. These findings reveal antibody adaptation to non-neutralizing intracellular antigens during infection, emphasizing the importance of vaccination for inducing neutralizing spike-specific MBCs.

antibody↗

SARS-CoV-2 Infection Severity Is Linked to Superior Humoral Immunity against the Spike

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is currently causing a global pandemic. The antigen specificity of the antibody response mounted against this novel virus is not understood in detail. Here, we report that subjects with a more severe SARS-CoV-2 infection exhibit a larger antibody response against the spike and nucleocapsid protein and epitope spreading to subdominant viral antigens, such as open reading frame 8 and nonstructural proteins. Subjects with a greater antibody response mounted a larger memory B cell response against the spike, but not the nucleocapsid protein. Additionally, we revealed that antibodies against the spike are still capable of binding the D614G spike mutant and cross-react with the SARS-CoV-1 receptor binding domain. Together, this study reveals that subjects with a more severe SARS-CoV-2 infection exhibit a greater overall antibody response to the spike and nucleocapsid protein and a larger memory B cell response against the spike.

60 APPLIED LIFE SCIENCES↗

Hubble Space Telescope high resolution spectroscoy of the exposed white dwarf in the dwarf nova VW Hydri in quiescence: A rapidly rotating white dwarf

We obtained a far-ultraviolet spectrum of the dwarf nova VW Hyi in quiescence, with the Hubble Space Telescope Goddard High Resolution Spectrograph covering the region of the Si iv lambda(lambda)1393, 1402 resonance doublet. The broad, shallow Si iv doublet feature is fully resolved, has a total equivalent width of 2.8 A, and is the first metal absorption feature to be clearly detected in the exposed white dwarf. Our synthetic spectral analysis, using a model grid constructed with the code TLUSTY, resulted in a reasonable fit to a white dwarf photosphere with T(sub eff) = 22,000 +/- 2000 K, log g = 8.0 +/- 0.3, an approximately solar Si/H abundance, and a rotational velocity, v sin i approximately equal to 600 km/s. This rotation rate, while not definitive because it is based upon just one line transition, is 20% of the Keplerian (breakup) velocity of the white dwarf and hence does not account for the unexpectedly low boundary-layer luminosity inferred from the soft-X-ray/extreme ultra-violet bands where most of the boundary-layer luminosity should be radiated. The predicted boundary-layer luminosity for a 0.6 solar mass white dwarf accreting at the rate 10(exp -10) solar mass/yr and rotating at 600 km/s, corresponding to VW Hyi in quiescence, is 2 x 10(exp 32) ergs/s when proper account is taken of the rotational kinetic energy going into spinning up the white dwarf. If the boundary-layer area is equal to that of the white dwarf, then T(sub bl) = 24,000 K. This is essentially identical to the photspheric luminosity and temperature determined in far-ultraviolet photospheric analyses. If the boundary-layer area is 10(exp -3) of the white dwarf surface area, then T(sub bl) = 136,000 K.

Sion, Edward M.↗

A Hubble Space Telescope study of the underlying white dwarf in the dwarf nova VW Hydri during quiescence

We have analyzed a far-ultraviolet spectrum of the dwarf nova VW Hyi obtained during quiescence with the Hubble Space Telescope Faint Object Spectrograph (HST FOS). The observation occurred 10 days after the return to optical quiescence from a superoutburst of VW Hyi. The spectrum reveals a very strong Stark-broadened Ly-alpha absorption with narrow geocoronal emission, and a very rich metallic absorption-line spectrum dominated by strong resonance absorption features of singly and doubly ionized silicon and carbon, the first solid identification of metallic absorption features arising in the accreted atmosphere of the white dwarf. We confirm the reported low-resolution IUE detection of the underlying white dwarf photosphere by Mateo & Szkody. A synthetic spectral analysis with hot, high-gravity LTE model atmospheres yields a best-fit model with the following parameters: T(sub eff) = 22,000 +/- 1000 K, log g = 8.0 +/- 0.3, with chemical abundances for oxygen of 0.3 times solar, for nitrogen of 5 times solar, and for all other heavy elements of 0.15 times solar. Based upon our absorption-line measurements of the observations at different orbital phases, we find no conclusive evidence of equivalent width variations with orbital phase. In the absence of any significant reduction of the white dwarf's core mass by past nova explosions, its lower limit cooling age is approximately 50 million years.

Sion, Edward M.↗

The cooling of the white dwarf in U Geminorum following heating by two different outbursts

We present the analysis of 13 orbital phase-resolved IUE (large and small aperture) SWP spectra, sampling the quiescent intervals of the proptotype dwarf nova U Geminorum following two individual outbursts, the outburst of 1992, 29 August-14 September, and the outburst of 1993, 19 March-5 April. The quiescent interval following the outburst 29 August 1992 is the longest ever recorded. During quiescence, the photospheric radiation of the exposed white dwarf dominates the far ultrviolet. The variations in absorption line strengths and continum flux levels are analyzed as a function of both orbital phase and elapsed time, since the return to optical quiescence, by fitting the IUE spectra with a grid of high gravity, LTE, model atmospheres with solar composition constructed with TLUSTY and SYNSPEC (Hubeny, I. Tlusty and Synnspec: A Users Guide (1994)). We present evidence from both absorption line variations and continuum variations, as a function of time since the outbursts, that the white dwarf photosphere has cooled by several thousand degrees. Within the signal-to-noise limitations, we find no evidence of a difference in heating and cooling between the two outbursts.

Huang, Min↗

Hubble Space Telescope FOS spectroscopy of the ultrashort-period dwarf nova WZ Sagittae: The underlying degenerate

Two consecutive Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) spectra of the exposed white dwarf in the ultrashort-period, high-amplitude, dwarf nova WZ Sge, reveal a rich absorption line spectrum of neutron carbon and ionized metals, the Stark-broadened Lyman-alpha absorption wing, the H2 quasi-molecular Lyman-alpha 'satellite' absorption line, and a double-peaked C IV emission line which is variable with orbital phase. A synthetic spectral analysis of the white dwarf yields T(sub eff) = 14,900 K +/- 250 K, log g = 8.0. In order to fit the strongest C I absorption lines and account for the weakness of the silicon absorption lines, the abundance of carbon in the photosphere must be approximately 0.5 solar, silicon abundance is 5 x 10(exp -3) solar, with all other metal species appearing to be 0.1-0.001 times solar. The H2 quasi-molecular absorption is fitted very successfully. The photospheric metals have diffusion timescales of fractions of a year, and thus they must have been accreted long after the 1978 December outburst. The source of the most abundance metal, carbon, is considered. If the time-averaged accretion rate during quiescence is low enough for diffusive equilibrium to prevail, then the equilibrium accretion rate pf neutron carbon is 7 x 10(exp -16) solar mass/yr. A convective dredge-up origin for the concentration of carbon is extremely unlikely, given that the white dwarf atmosphere is H-rich while in single degenerates showing carbon and hydrogen, the C and H are trace elements in a helium background. Additional implications are explored.

Sion, Edward M.↗

Hubble space telescope Goddard High-Resolution Spectrograph observation of U Geminorum during quiescence: Evidence for a slowly rotating white dwarf

We have obtained a pair of consecutive far-ultraviolet Goddard High-Resolution Spectrograph (GHRS) exposures of the Si IV region of the dwarf nova U Geminorum in early quiescence, 8 days after its return to optical quiescence when the underlying white dwarf dominates the ultraviolet light of the system. Our GHRS observation revealed a fully resolved line profile for the resonance doublet of Si IV. If it is associated with the white dwarf photosphere, then our best synthetic fits are consistent with T (sub eff) = 35,000 K-38,000 K, log g = 8, a rotational velocity of 50 to 100 km per sec, with a modestly enhanced silicon abundance (1.3-2.3 times solar) and our results suggest that at least in U Gem and perhaps in other similar dwarf novae, the missing boundary layer cannot be explained by rapid rotation of the white dwarf. However, the gamma-velocity of the system remains uncertain. If the gamma-velocity is 43 km per sec (Friend et al. 1990), then a gravitational redshift of approximately 50-60 km per sec is implied for the white dwarf. If the gamma-velocity is 84 km per sec (Wade 1981), then a gravitational redshift of only 10-30 km per sec is indicated, which may imply that either the white dwarf has a low (0.5-0.6 of Solar Mass) mass or an extended atmosphere (corona) due to the outburst heating 8 days earlier. The implications of our line-fitting results for the structure and temperature of boundary layers in cataclysmic variables are discussed.

Sion, Edward M.↗

Cooling of the white dwarf in U Geminorum between outbursts

We have obtained far-ultraviolet (1150-1610 A) spectra of U Gem with the Faint Object Spectrograph on the Hubble Space Telescope approximately 13 and 70 days after the end of a normal dwarf nova outburst of the system. Both spectra appear dominated by the White Dwarf (WD) in U Gem. At 1400 A, the flux from U Gem declined approximately 28% between the two observations. Detailed comparison of the spectra with solar abundance WD models suggest that average surface temperature of the WD surface cooled from approximately 39,400 K to approximately 32,100 K between the two observations. The main features which are not fitted well by WD models are absorption due to N V lambda lambda-1239, 1243 and emission at Lyman-alpha. These observations provide unambiguous confirmation that the WD in U Gem cools during quiescence, as was suggested by analyses of far-ultraviolet spectra obtained with International Ultraviolet Explorer (IUE) and Hopkins Ultraviolet Telescope (HUT).

Long, Knox S.↗

Thermal instability accretion disk model for the X-ray transient A0620-00

The limit-cycle thermal instability model for accretion disks is used to study the soft X-ray transient A0620-00. Thermal instability in geometrically thin, Keplerian alpha-model disks is reviewed. The observational constraints on A0620-00 are presented and the parameters chosen for the model are discussed. It is found that, with the adopted parameters, the model requires a central object mass of about 7 solar masses to fit the burst recurrence time. This is consistent with a black hole as the central object. The results suggest that a mass transfer instability may be responsible for outbursts.

Huang, Min↗