Search NASA⌕ Search

Engineering topics

Huang, W.

Publications and source records attributed to Huang, W..

At least 19 records

Spectroscopic Determination of Key Energy Scales for the Base Hamiltonian of Chromium Trihalides

The van der Waals (vdW) chromium trihalides (CrX 3 ) exhibit field-tunable, two-dimensional magnetic orders that vary with the halogen species and the number of layers. Their magnetic ground states with proximity in energies are sensitive to the degree of ligand-metal (p-d) hybridization and relevant modulations in the Cr d-orbital interactions. We use soft X-ray absorption (XAS) and resonant inelastic X-ray scattering (RIXS) spectroscopy at Cr L -edge along with the atomic multiplet simulations to determine the key energy scales such as the crystal field 10 Dq and interorbital Coulomb interactions under different ligand metal charge transfer (LMCT) in CrX 3 (X= Cl, Br, and I). Through this systematic study, we show that our approach compared to the literature has yielded a set of more reliably determined parameters for establishing a base Hamiltonian for CrX 3 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beyond the acceptance limit of DRAGON: The case of the 6 Li(α,γ) 10 B reaction

Radiative capture reactions play a pivotal role for our understanding of the origin of the elements in the cosmos. Recoil separators provide an effective way to study these reactions, in inverse kinematics, and take advantage of the use of radioactive ion beams. However, a limiting factor in the study of radiative capture reactions in inverse kinematics is the momentum spread of the product nuclei, which can result in an angular spread larger than the geometric acceptance of the separator. The DRAGON facility at TRIUMF is a versatile recoil separator, designed to study radiative capture reactions relevant to astrophysics in the A~10–30 region. In this work we present the first attempt to study with DRAGON a reaction, 6 Li(α, γ) 10 B, for which the recoil angular spread exceeds DRAGON’s acceptance. Furthermore, our result is in good agreement with the literature value, showing that DRAGON can measure resonance strengths of astrophysically important reactions even when not all the recoils enter the separator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A cavity ring-down spectroscopy sensor for real-time Hall thruster erosion measurements

A continuous-wave cavity ring-down spectroscopy sensor for real-time measurements of sputtered boron from Hall thrusters has been developed. The sensor uses a continuous-wave frequency-quadrupled diode laser at 250 nm to probe ground state atomic boron sputtered from the boron nitride insulating channel. Validation results from a controlled setup using an ion beam and target showed good agreement with a simple finite-element model. Application of the sensor for measurements of two Hall thrusters, the H6 and SPT-70, is described. The H6 was tested at power levels ranging from 1.5 to 10 kW. Peak boron densities of 10 ± 2 × 10{sup 14} m{sup −3} were measured in the thruster plume, and the estimated eroded channel volume agreed within a factor of 2 of profilometry. The SPT-70 was tested at 600 and 660 W, yielding peak boron densities of 7.2 ± 1.1 × 10{sup 14} m{sup −3}, and the estimated erosion rate agreed within ∼20% of profilometry. Technical challenges associated with operating a high-finesse cavity in the presence of energetic plasma are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Crystalline Multimetallic Nanoframes with Three-Dimensional Electrocatalytic Surfaces

Control of structure at the atomic level can precisely and effectively tune catalytic properties of materials, enabling enhancement in both activity and durability. We synthesized a highly active and durable class of electrocatalysts by exploiting the structural evolution of platinum-nickel (Pt-Ni) bimetallic nanocrystals. The starting material, crystalline PtNi 3 polyhedra, transforms in solution by interior erosion into Pt 3 Ni nanoframes with surfaces that offer three-dimensional molecular accessibility. The edges of the Pt-rich PtNi 3 polyhedra are maintained in the final Pt 3 Ni nanoframes. Both the interior and exterior catalytic surfaces of this open-framework structure are composed of the nanosegregated Pt-skin structure, which exhibits enhanced oxygen reduction reaction (ORR) activity. The Pt 3 Ni nanoframe catalysts achieved a factor of 36 enhancement in mass activity and a factor of 22 enhancement in specific activity, respectively, for this reaction (relative to state-of-the-art platinum-carbon catalysts) during prolonged exposure to reaction conditions.

36 MATERIALS SCIENCE↗

Measurement of conductivity and permittivity on samples sealed in nuclear magnetic resonance tubes

We present a broadband impedance spectroscopy instrument designed to measure conductivity and/or permittivity for samples that are sealed in glass tubes, such as the standard 5 mm tubes used for nuclear magnetic resonance experiments. The calibrations and corrections required to extract the dielectric properties of the sample itself are outlined. It is demonstrated that good estimates of the value of dc-conductivity can be obtained even without correcting for the effects of glass or air on the overall impedance. The approach is validated by comparing data obtained from samples sealed in nuclear magnetic resonance tubes with those from standard dielectric cells, using glycerol and butylmethylimidazolium-hexafluorophosphate as respective examples of a molecular and an ionic liquid. This instrument and approach may prove useful for other studies of permittivity and conductivity where contact to the metal electrodes or to the ambient atmosphere needs to be avoided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Remote Sensing Filter Radiometer Employing a Fabry-Perot Etalon and a CCD Camera for Column Measurements of Methane in the Earth Atmosphere

A portable remote sensing system for precision column measurements of methane has been developed, built and tested at NASA GSFC. The sensor covers the spectral range from 1.636 micrometers to 1.646 micrometers, employs an air-gapped Fabry-Perot filter and a CCD camera and has a potential to operate from a variety of platforms. The detector is an XS-1.7-320 camera unit from Xenics Infrared solutions which combines an uncooled InGaAs detector array working up to 1.7 micrometers. Custom software was developed in addition to the graphical user basic interface X-Control provided by the company to help save and process the data. The technique and setup can be used to measure other trace gases in the atmosphere with minimal changes of the etalon and the prefilter. In this paper we describe the calibration of the system using several different approaches.

Georgieva, E. M.↗

A Broad Bank Lidar for Precise Atmospheric CO2 Column Absorption Measurement from Space

Accurate global measurement of carbon dioxide column with the aim of discovering and quantifying unknown sources and sinks has been a high priority for the last decade. In order to uncover the "missing sink" that is responsible for the large discrepancies in the budget the critical precision for a measurement from space needs to be on the order of 1 ppm. To better understand the CO2 budget and to evaluate its impact on global warming the National Research Council (NRC) in its recent decadal survey report (NACP) to NASA recommended a laser based total CO2 mapping mission in the near future. That's the goal of Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission - to significantly enhance the understanding of the role of CO2 in the global carbon cycle. Our current goal is to develop an ultra precise, inexpensive new lidar system for column measurements of CO2 changes in the lower atmosphere that uses a Fabry-Perot interferometer based system as the detector portion of the instrument and replaces the narrow band laser commonly used in lidars with a high power broadband source. This approach reduces the number of individual lasers used in the system and considerably reduces the risk of failure. It also tremendously reduces the requirement for wavelength stability in the source putting this responsibility instead on the Fabry- Perot subsystem.

Georgieva, E. M.↗

Breakdown Degradation Associated with Elementary Screw Dislocations in 4H-SiC P(+)N Junction Rectifiers

It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vector greater than 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = lc with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. This paper describes an initial study into the impact of elementary screw dislocations on the reverse-bias current-voltage (I-V) characteristics of 4H-SiC p(+)n diodes. First, Synchrotron White Beam X-ray Topography (SWBXT) was employed to map the exact locations of elementary screw dislocations within small-area 4H-SiC p(+)n mesa diodes. Then the high-field reverse leakage and breakdown properties of these diodes were subsequently characterized on a probing station outfitted with a dark box and video camera. Most devices without screw dislocations exhibited excellent characteristics, with no detectable leakage current prior to breakdown, a sharp breakdown I-V knee, and no visible concentration of breakdown current. In contrast devices that contained at least one elementary screw dislocation exhibited a 5% to 35% reduction in breakdown voltage, a softer breakdown I-V knee, and visible microplasmas in which highly localized breakdown current was concentrated. The locations of observed breakdown microplasmas corresponded exactly to the locations of elementary screw dislocations identified by SWBXT mapping. While not as detrimental to SiC device performance as micropipes, the undesirable breakdown characteristics of elementary screw dislocations could nevertheless adversely affect the performance and reliability of 4H-SiC power devices.

Neudeck, P. G.↗

Non-Isothermal Calorimetric Studies of the Crystallization of Lithium Disilicate Glass

The influence of preannealing treatments on the polymorphic crystallization of lithium disilicate glasses is examined. As expected, glasses heated at different rates through the temperature range where there is significant nucleation develop widely different numbers of nuclei. This can dramatically influence the stability and transformation characteristics of the annealed glass. Non-isothermal differential scanning calorimetry (DSC) and differential thermal analysis (DTA) measurements are demonstrated to be useful to probe the nucleation behavior. The first systematic investigations of particle size effects on the non-isothermal transformation behavior are presented and discussed. Based on DTA and microscopy experiments, we show that small particles of lithium disilicate glasses crystallize primarily by surface crystallization. The relative importance of surface versus volume crystallization is examined by varying particle size, by introducing nucleating agents and by exposing glasses to atmospheres of different water content. These data are analyzed quantitatively using a numerical model developed in a second paper following in this volume.

Ray, C. S.↗

Three-dimensional Navier-Stokes calculations using solution-adapted grids

A three-dimensional solution-adaptive grid generation technique is presented. The adaptation technique redistributes grid points to improve the accuracy of a flow solution without increasing the number of grid points. It is applicable to structured grids with a multiblock topology. The method uses a numerical mapping and potential theory to modify the initial grid distribution based on the properties of the flow solution on the initial grid. The technique is demonstrated with two examples - a transonic finite wing and a supersonic blunt fin. The advantages are shown by comparing flow solutions on the adapted grids with those on the initial grids.

Henderson, T. L.↗

Dependence of the critical cooling rate for lithium-silicate glass on nucleating agents

The critical cooling rate, Rc, for glass formation of a glass containing 40 mol pct Li2O and 60 mol pct SiO2, doped with small amounts of Pt, Au, P2O5, and TiO2 nucleating agents, has been measured. Rc increases with increasing Pt and Au additions, but Pt has a larger effect than Au. Additions of P2O5 tend to decrease Rc, whereas TiO2 has practically no effect on Rc. The devitrified glass nucleated with Pt contains only crystalline Li2O-SiO2, but all the other devitrified glasses, including the undoped glass, contain both Li2O-SiO2 and Li2O-2SiO2. Analysis shows that Rc increases as the concentration of the Li2O-SiO2 phase in the devitrified glass increases.

Huang, W.↗