Search NASA⌕ Search

Engineering topics

Huang, Xiaodan

Publications and source records attributed to Huang, Xiaodan.

Rapid, Sensitive, Label-Free Electrical Detection of SARS-CoV-2 in Nasal Swab Samples

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcriptionpolymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Finally, taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.

60 APPLIED LIFE SCIENCES↗

Remote Floating-Gate Field-Effect Transistor with 2-Dimensional Reduced Graphene Oxide Sensing Layer for Reliable Detection of SARS-CoV-2 Spike Proteins

Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. In this work, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of two-dimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO–solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nernstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 μg/mL, with an R 2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects on the Ocular Surface from Reading on Different Smartphone Screens: A Prospective Randomized Controlled Study

The purpose of this study was to investigate the influence of smartphone reading on the ocular surface and to compare the various effects of different screens and light conditions on the ocular surface. One hundred nineteen volunteers were randomly divided into: light + organic light‐emitting diode (OLED), light + electronic ink (eINK), dark + OLED, and dark + eINK. Ocular surface examinations, including noninvasive break‐up time (NIBUT), noninvasive keratograph tear meniscus height (NIKTMH), ocular redness, fluorescein break‐up time (FBUT), corneal fluorescein staining, meibomian gland assessment, Schirmer I Test, and blinking frequency, were performed before and after a reading task. Symptoms were evaluated using the Ocular Surface Disease Index (OSDI) and Computer Vision Syndrome Questionnaire (CVS‐Q). NIBUT and FBUT were decreased statistically significantly after participants read on an OLED screen for 2 hours compared with the baseline in light and dark environments, whereas no statistically significant decrease was observed on an eINK screen. NIKTMH was statistically significantly decreased after reading on an OLED screen in light and dark settings, and the eINK screen had a lesser effect on NIKTMH. An obvious increase in the ocular redness, OSDI and CVS‐Q scores was observed after reading on an OLED screen, whereas the eINK screen had a lesser effect on these indicators. Blink rate increased gradually in OLED subgroups during the reading task, whereas no statistically significant difference was observed in the eINK subgroups. Our research suggested that reading on an OLED screen can cause ocular surface disorder and obvious subjective discomfort, whereas reading on an eINK screen can minimize ocular surface disorder in both dark and light environments.

Yuan, Kelan↗