Search NASA⌕ Search

Engineering topics

Hudson, W. G.

Publications and source records attributed to Hudson, W. G..

The design and performance of axially symmetrical contoured wall diffusers employing suction boundary layer control

This paper presents a procedure for the design and the performance prediction of axially symmetrical contoured wall diffusers employing suction boundary layer control. An inverse problem approach was used in the potential flow design of the diffuser wall contours. The experimentally observed flow characteristics and the stability of flows within the diffuser are also described. Guidelines for the design of low suction (less than 10 percent of the inlet flow) and thus high effectiveness contoured wall diffusers are also provided based on the results of the experimental program.

Nelson, C. D., Jr.↗

Design and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction

The feasibility of designing short curved wall axially symmetrical subsonic diffusers utilizing suction through slots in the diffuser walls to prevent flow separation was investigated. A potential flow analysis was made, and a digital computer program was written for determining the diffuser wall contour for prescribed boundary conditions. The flow field included branch flow so that the suction slot geometry could be a part of the diffuser design. One bell shaped diffuser and three annular diffusers with area ratios of either 2.5:1 or 3:1 were designed, fabricated, and tested. Minimum suction requirements of metastable operation ranged from 6.3 percent to 12 percent when operating with inlet air velocities in the 1000 to 250 ft/sec (30 to 76 m/sec) range. For stable operation suction rates from 10 percent to 22 percent were required. In all cases the diffuser effectiveness was above 95 percent based on the conventional definition, and from 81 percent to 94 percent when the suction loss was accounted for. The exit velocity profiles were virtually flat with no more than + or - 9% variation over 95 percent of the exit area when operated with sufficient suction to prevent flow separation.

Yang, T.↗

An improved design method and experimental performance of two dimensional curved wall diffusers

A computer design program was developed to incorporate the suction slots in solving the potential flow equations with prescribed boundary conditions. Using the contour generated from this program two Griffith diffusers were tested having area ratios AR = 3 and 4. The inlet Reynolds number ranged from 600,000 to 7 million. It was found that the slot suction required for metastable operation depends on the sidewall suction applied. Values of slot suction of 8% of the inlet flow rate was required for AR = 4 with metastable condition, provided that enough sidewall suction was applied. For AR = 3, the values of slot suction was about 25% lower than those required for AR = 4. For nearly all unseparated test runs, the effectiveness was 100% and the exit flow was uniform. In addition to the Griffith diffusers, dump and cusp diffusers of comparable area ratios were built and tested. The results obtained from these diffusers were compared with those of the Griffith diffusers. Flow separation occurred in all test runs with the dump and cusp diffusers.

Yang, T.↗