Search NASA⌕ Search

Engineering topics

Huff, Shean

Publications and source records attributed to Huff, Shean.

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Auto Stop-Start Fuel Consumption Benefits

With increasingly stringent regulations mandating the improvement of vehicle fuel economy, automotive manufacturers face growing pressure to develop and implement technologies that improve overall system efficiency. One such technology is an automatic (auto) stop-start feature. Auto stop-start reduces idle time and reduces fuel use by temporarily shutting the engine off when the vehicle comes to a stop and automatically re-starting it when the brake is released, or the accelerator is pressed. As mandated by the U.S. Congress, the U.S. Environmental Protection Agency (EPA) is required to keep the public informed about fuel saving practices. This is done, in partnership with the U.S. Department of Energy (DOE), through the fueleconomy.gov website. The “Fuel-Saving Technologies” and “Gas Mileage Tips” sections of the website are focused on helping the public make informed purchasing decisions and encouraging fuel-saving driving habits. Here, in order to provide users with accurate information about the auto stop-start feature, experiments were conducted to determine its fuel economy effect. Four vehicles were tested both with and without the feature enabled under three test cycles: the Federal Test Procedure (FTP) city fuel economy test, the US06 high acceleration aggressive driving schedule that is often identified as the “Supplemental FTP” driving schedule, and the EPA New York City Cycle (NYCC). The results were compared to measure the fuel economy and consumption effects of using the auto stop-start feature. It was found that the fuel economy improvement varied significantly between drive cycles depending on the amount and percentage of idle time during the test. The largest fuel economy improvements were 7.27% and 26.4% for the FTP and NYCC, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

Development and Evaluation of Chip-Enabled Raised Pavement Markers for Lane Line Detection

Increased energy consumption from autonomous vehicle (AV) sensors and computational load as well as upfront costs of sensors are barriers to broad AV adoption. For high quality and reliable perception of the driving environment, incoming data from multiple sensors need to be fused together using advanced computational algorithms, which requires a high compute load. As an alternative, infrastructure-based sensors can be designed to facilitate perception and sensing by supporting vehicle-to-infrastructure (V2I) information exchange. This work presents the initial development and evaluation of a novel energy efficient infrastructure-based sensor. The sensor, a chip-enabled raised pavement marker (CERPM), is capable of wireless communications to exchange environment information with AVs. As a test case, the developed CERPM is applied in real-world driving to perform lane line and drivable region detection for an AV. It is shown that CERPMs can be utilized to effectively detect the lane line and drivable region, which can improve perception while reducing the compute load.

Sharma, Sachin↗

Development of an Energy Efficient and Cost Effective Autonomous Vehicle Research Platform

Commercialization of autonomous vehicle technology is a major goal of the automotive industry, thus research in this space is rapidly expanding across the world. However, despite this high level of research activity, literature detailing a straightforward and cost-effective approach to the development of an AV research platform is sparse. To address this need, we present the methodology and results regarding the AV instrumentation and controls of a 2019 Kia Niro which was developed for a local AV pilot program. This platform includes a drive-by-wire actuation kit, Aptiv electronically scanning radar, stereo camera, MobilEye computer vision system, LiDAR, inertial measurement unit, two global positioning system receivers to provide heading information, and an in-vehicle computer for driving environment perception and path planning. Robotic Operating System software is used as the system middleware between the instruments and the autonomous application algorithms. After selection, installation, and integration of these components, our results show successful utilization of all sensors, drive-by-wire functionality, a total additional power* consumption of 242.8 Watts (*Typical), and an overall cost of $118,189 USD, which is a significant saving compared to other commercially available systems with similar functionality. This vehicle continues to serve as our primary AV research and development platform.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluating Efficiency and Security of Connected and Autonomous Vehicle Applications

Evaluating efficiency and security of Connected and Autonomous Vehicles (CAVs) requires an environment that can support applications and measurements under real-world conditions. This work introduces our implementation and evaluation of a Connected and Autonomous Vehicle Research Environment (CAVRE). We implement and evaluate an existing CAV application called Cooperative Adaptive Cruise Control (CACC) using physical Vehicle-to-Vehicle (V2V) communications between a virtual agent and a real autonomous vehicle operating on a steerable dynamometer. CAVRE allows the follower to autonomously control longitudinal behavior on the dynamometer in order to maintain a steady following time gap from the leader. The effects of a wireless jamming attack on CACC and fuel efficiency is also evaluated. By executing attacks in a controlled environment, we learn how compromised communications can degrade CAV applications. We show that jamming V2V communications can impact CACC’s string stability and decrease fuel efficiency by more than 50%.

Taylor, Curtis↗