Search NASA⌕ Search

Engineering topics

Hui, Li

Publications and source records attributed to Hui, Li.

25 records · Page 2

Photo-degradation of methylene blue using Ta-doped ZnO nanoparticle

A photocatalyst of Ta-doped ZnO was prepared by a modified Pechini-type method. The structural, morphological properties and photocatalytic activity of 1 mol % Ta-doped ZnO samples annealed at different temperatures were characterized. The photo-oxidation of methylene blue under the visible-light irradiation followed the pseudo-first-order kinetics according to the Langmuir-Hinshelwood model. It is found that the photocatalysis of 1% Ta-doped ZnO annealed at 700 {sup o}C showed excellent performance of the photodegradation of methylene blue, which was attributed to a competitive trade-off among the crystallinity, surface hydroxyl groups, and specific surface area. The processing parameter such as the pH value also played an important role in tuning the photocatalytic activity. The maximum photodecomposed rate was achieved at pH=8, and an novel model about the absorption of methylene blue on the surface of the catalysts was proposed. - Graphical abstract: This model describes the adsorption between the amphoteric behavior of the metal oxide and the cationic dye methylene blue (MB) on the surface of the catalyst at the acidic and alkaline condition.

36 MATERIALS SCIENCE↗

COSMOLOGICAL ADAPTIVE MESH REFINEMENT MAGNETOHYDRODYNAMICS WITH ENZO

In this work, we present EnzoMHD, the extension of the cosmological code Enzo to include the effects of magnetic fields through the ideal magnetohydrodynamics approximation. We use a higher order Godunov method for the computation of interface fluxes. We use two constrained transport methods to compute the electric field from those interface fluxes, which simultaneously advances the induction equation and maintains the divergence of the magnetic field. A second-order divergence-free reconstruction technique is used to interpolate the magnetic fields in the block-structured adaptive mesh refinement framework already extant in Enzo. This reconstruction also preserves the divergence of the magnetic field to machine precision. We use operator splitting to include gravity and cosmological expansion. We then present a series of cosmological and non-cosmological test problems to demonstrate the quality of solution resulting from this combination of solvers.

79 ASTRONOMY AND ASTROPHYSICS↗

POLARIZED EMISSION OF SAGITTARIUS A*

We explore the parameter space of the two-temperature pseudo-Newtonian Keplerian accretion flow model for the millimeter and shorter wavelength emission from Sagittarius A*. A general relativistic (GR) ray-tracing code is used to treat the radiative transfer of polarized synchrotron emission from the flow. The synchrotron self-Comptonization and bremsstrahlung emission components are also included. It is shown that the model can readily account for the millimeter to submillimeter emission characteristics with an accretion rate of {approx}6 x 10{sup 17} g s{sup -1} and an inclination angle of {approx}40 deg. However, the corresponding model-predicted near-infrared (NIR) and X-ray fluxes are more than one order of magnitude lower than the observed 'quiescent' state values. While the extended quiescent-state X-ray emission has been attributed to thermal emission from the large-scale accretion flow, the NIR emission and flares are likely dominated by emission regions either within the last stable orbit of a Schwarzschild black hole or associated with outflows. With the viscous parameter derived from numerical simulations, there is still a degeneracy between the electron heating rate and the magnetic parameter. A fully GR treatment with the black hole spin incorporated will resolve these issues.

79 ASTRONOMY AND ASTROPHYSICS↗

Preparation, characterization of the Ta-doped ZnO nanoparticles and their photocatalytic activity under visible-light illumination

This paper describes a novel catalyst of the Ta-doped ZnO nanocrystals prepared by a modified polymerizable complex method using the water-soluble tantalum precursor as the sources of Ta. The catalysts were characterized by means of various analytical techniques as a function of Ta content (x=0-4 mol%) systematically. A remarkable advantage of the results was confirmed that dopant Ta enhanced the visible-light absorption of ZnO and the low-solubility tantalum doping could restrain the growth of crystal and minish the particle size. The relationship between the physicochemical property and the photocatalytic performance was discussed, and it was found that the photocatalytic activity in the photochemical degradation of methylene blue under visible-light irradiation (lambda>=420 nm) was dependent on the contents of the dopant, which could affect the particle size, concentration of surface hydroxyl groups and active hydrogen-related defect sites, and the visible-light absorption. The highest photocatalytic activity was obtained for the 1.0 mol% Ta-doped ZnO sample. - Graphical abstract: The addition of the tantalum into ZnO prepared by a modified polymerizable complex method not only restrains the growth of crystal, minish the particle size, but also changes the nanocrystal morphology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Investigation of hepatic fibrosis in rats with x-ray diffraction enhanced imaging

X-ray diffraction enhanced imaging (DEI) is a phase contrast technique that generates excellent contrast of biological soft tissues compared to conventional absorption radiography. We explore the application of DEI in the diagnosis of hepatic fibrosis. The produced refraction contrast images of fibrous rat liver samples show clearly abnormal liver architectures. Moreover, by comparing to histological pictures, different stages of fibrosis are discriminated, and the corresponding morphological features are analyzed. Besides, quantitative analyses of texture features are presented. The results reported herein show that DEI can be a potential noninvasive technique to diagnose and stage hepatic fibrosis.

60 APPLIED LIFE SCIENCES↗

Using {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography to Estimate the Length of Gross Tumor in Patients With Squamous Cell Carcinoma of the Esophagus

Purpose: To determine the optimal method of using {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) to estimate gross tumor length in esophageal carcinoma. Methods and Materials: Thirty-six patients with esophageal squamous cell carcinoma treated with radical surgery were enrolled. Gross tumor volumes (GTVs) were delineated using three different methods: visual interpretation, standardized uptake value (SUV) 2.5, and 40% of maximum standard uptake value (SUV{sub max}) on FDG-PET imaging. The length of tumors on PET scan were measured and recorded as Length{sub vis}, Length{sub 2.5}, and Length{sub 40}, respectively, and compared with the length of gross tumor in the resected specimen (Length{sub gross}). All PET data were reviewed again postoperatively, and the GTV was delineated using various percentages of SUV{sub max}. The optimal-threshold SUV was generated when the length of PET matched the Length{sub gross}. Results: The mean ({+-}SD) Length{sub gross} was 5.48 {+-} 1.98 cm. The mean Length{sub vis}, Length{sub 2.5}, and Length{sub 40} were 5.18 {+-} 1.93 cm, 5.49 {+-} 1.79 cm, and 4.34 {+-} 1.54 cm, respectively. The mean Length{sub vis} (p = 0.123) and Length{sub 2.5} (p = 0.957) were not significantly different from Length{sub gross}, and Length{sub 2.5} seems more approximate to Length{sub gross.} The mean Length{sub 40} was significantly shorter than Length{sub gross} (p < 0.001). The mean optimal threshold was 23.81% {+-} 11.29% for all tumors, and it was 19.78% {+-} 8.59%, 30.92% {+-} 12.28% for tumors {>=}5 cm, and <5 cm, respectively (p = 0.009). The correlation coefficients of the optimal threshold were -0.802 and -0.561 with SUV{sub max} and Length{sub gross}, respectively. Conclusions: The optimal PET method to estimate the length of gross tumor varies with tumor length and SUV{sub max}; an SUV cutoff of 2.5 provided the closest estimation in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlative feature analysis on FFDM

Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer-aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual-stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two-step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, the distance feature yielded an area under the ROC curve (AUC) of 0.81{+-}0.02 with leave-one-out (by physical lesion) evaluation, and the feature metric subset, which included distance, gradient texture, and ROI-based correlation, yielded an AUC of 0.87{+-}0.02. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗