Collaborative RFID reader using code divisional multiple access (CDMA) and methods for same

The present disclosure provides collaborative radiofrequency identification (RFID) readers that employ code division multiple access (CDMA) encoding to simultaneously broadcast to and read responses from tags in an overlapping reading zone with improved data synchronization and read yield rates. In some embodiments, a harmonic backscattering scheme is used to enable the system to have a much higher signal-to-noise ratio (SNR) and sensitivity, while the reader CDMA protocol can be integrated with an initial TDMA polling process or alternative tag CDMA scheme.

Kan, Edwin C.↗

System and method for ultra-high-resolution ranging using RFID

A radio-frequency method for range finding includes modulating a reference signal having an intermediate frequency to a downlink signal having a carrier frequency using a clock signal. The downlink signal is transmitted to a tag using a transceiver. An uplink signal backscattered front the tag is received and demodulated using the clock signal. The uplink signal has a frequency that is a harmonic of the carrier frequency. A distance between the tag and the transceiver is calculated based on a phase of the demodulated uplink signal. A system for range finding includes a transceiver and a processor. The transceiver modulates a reference signal to downlink signal and transmits the downlink signal. The transceiver receives and demodulates an uplink signal. The processor is configured to receive the demodulated uplink signal and calculate a distance between the tag and the transceiver using a phase of the demodulated uplink signal.

Hui, Xiaonan↗

Methods and systems for electromagnetic near-field coherent sensing

The present disclosure may be embodied as methods and/or systems for non-contact measuring of an on-body and/or inside-body motion of an individual. A sensing signal is provided within a near-field coupling range of a motion to be measured. In this way, a measurement signal may be generated as the sensing signal modulated by the motion. The sensing signal may be an ID-modulated signal. In some embodiments, the sensing signal is a backscattered RFID link provided a wireless tag. A downlink signal may be provided to power the wireless tag. The sensing signal may be a harmonic of the downlink signal. The measurement signal is detected. The motion is measured based on the measurement signal. The measurement signal may be detected as far-field radiation after transmission through a source of the motion. The measurement signal may be detected as reflected from a source of the motion as antenna reflection.

Hui, Xiaonan↗

System and method for ultra-high-resolution ranging using RFID

A radio-frequency method for range finding includes modulating a reference signal having an intermediate frequency to a downlink signal having a carrier frequency using a clock signal. The downlink signal is transmitted to a tag using a transceiver. An uplink signal backscattered from the tag is received and demodulated using the clock signal. The uplink signal has a frequency that is a harmonic of the carrier frequency. A distance between the tag and the transceiver is calculated based on a phase of the demodulated uplink signal. A system for range finding includes a transceiver and a processor. The transceiver modulates a reference signal to a downlink signal and transmits the downlink signal. The transceiver receives and demodulates an uplink signal. The processor is configured to receive the demodulated uplink signal and calculate a distance between the tag and the transceiver using a phase of the demodulated uplink signal.

Hui, Xiaonan↗

Collaborative RFID reader using code divisional multiple access (CDMA) and methods for same

The present disclosure provides collaborative radiofrequency identification (RFID) readers that employ code division multiple access (CDMA) encoding to simultaneously broadcast to and read responses from tags in an overlapping reading zone with improved data synchronization and read yield rates. In some embodiments, a harmonic backscattering scheme is used to enable the system to have a much higher signal-to-noise ratio (SNR) and sensitivity, while the reader CDMA protocol can be integrated with an initial TDMA polling process or alternative tag CDMA scheme.

Kan, Edwin C.↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

No-touch measurements of vital signs in small conscious animals

Measuring the heartbeat and respiration of small conscious animals is important for assessing their health and behavior, but present techniques such as electrocardiogram (ECG), ultrasound, and auscultation rely on close skin contact with the animal. These methods can also require surface preparation, cause discomfort or stress to animals, and even require anesthetic administration, especially for birds, reptiles, and fish. Here, we show that radio frequency near-field coherent sensing (NCS) can provide a new solution to animal vital sign monitoring while ensuring minimal pain and distress. We first benchmarked NCS with synchronous ECG on an anesthetized rat. NCS was then applied to monitor a conscious hamster from outside its cage, and was further extended to a parakeet, Russian tortoise, and betta fish in a noninvasive manner. Our system can revolutionize vital sign monitoring of small conscious animals in their laboratory living quarters or natural habitats.

47 OTHER INSTRUMENTATION↗