CFD Validation and Scaling of a Condenser Used in an ISRU Propellant Production System
This work develops a Computational Fluid Dynamics (CFD) model of a Commercial-Off-The-Shelf (COTS) condenser used for ground-based testing of an In-Situ Resource Utilization (ISRU) propellant production system. STAR-CCM+ was used to simulate water condensing through the condenser downstream of a methanation reactor. The computational data of the digital model is validated with test cases using nitrogen and water in ambient conditions. After validation with the test data, the digital model can be used to predict scale at higher production targets. The StarCCM+ simulation of the digital model shows good agreement with the test data provided. From the simulation, the condensation rate calculated was 18.3 g/hr and the process gas mass flow rate was 709.2 g/hr. The test data measured an average 16.9 g/hr condensation rate and 693.6 g/hr process gas mass flow rate. The simulation shows a 7.3% error in the water condensation and 2.2% error in the process gas at the outlet.