Engineering topics
Hutcheon, I
Publications and source records attributed to Hutcheon, I.
The Uranium Sourcing Database Project: Practical Insights into the Establishment and Application of a Nuclear Forensics Library
Abstract not provided
Characterization of Uranium Oxyfluoride Particles for Nuclear Safeguards
Abstract not provided
Investigating Chemical and Molecular Changes in Uranium Oxyfluoride Particles using NanoSIMS and Micro-Raman Spectroscopy
Abstract not provided
Measuring Fluorine in Uranium Oxyfluoride Particles using Secondary Ion Mass Spectrometry for Nuclear Forensics
Abstract not provided
Study of Chemical Changes in Uranium Oxyfluoride Particles Progress Report March - October 2009
Nuclear forensics relies on the analysis of certain sample characteristics to determine the origin and history of a nuclear material. In the specific case of uranium enrichment facilities, it is the release of trace amounts of uranium hexafluoride (UF{sub 6}) gas - used for the enrichment of uranium - that leaves a process-characteristic fingerprint. When UF{sub 6} gas interacts with atmospheric moisture, uranium oxyfluoride particles or particle agglomerates are formed with sizes ranging from several microns down to a few tens of nanometers. These particles are routinely collected by safeguards organizations, such as the International Atomic Energy Agency (IAEA), allowing them to verify whether a facility is compliant with its declarations. Spectrometric analysis of uranium particles from UF{sub 6} hydrolysis has revealed the presence of both particles that contain fluorine, and particles that do not. It is therefore assumed that uranium oxyfluoride is unstable, and decomposes to form uranium oxide. Understanding the rate of fluorine loss in uranium oxyfluoride particles, and the parameters that control it, may therefore contribute to placing boundaries on the particle's exposure time in the environment. Expressly for the purpose of this study, we prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (EU-JRC-IRMM) from a static release of UF{sub 6} in a humid atmosphere. The majority of the samples was stored in controlled temperature, humidity and lighting conditions. Single particles were characterized by a suite of micro-analytical techniques, including NanoSIMS, micro-Raman spectrometry (MRS), scanning (SEM) and transmission (TEM) electron microscopy, energy-dispersive X-ray spectrometry (EDX) and focused ion beam (FIB). The small particle size was found to be the main analytical challenge. The relative amount of fluorine, as well as the particle chemical composition and morphology were determined at different stages in the ageing process, and immediately after preparation. This report summarizes our most recent findings for each of the analytical techniques listed above, and provides an outlook on what remains to be resolved. Additional spectroscopic and mass spectrometric measurements were carried out at Pacific Northwest National Laboratory, but are not included in this summary.
Constraints on the Formation Age of Cometary Material from the NASA Stardust Mission
We measured the {sup 26}Al-{sup 26}Mg isotope systematics of a {approx} 5-micrometer refractory particle, Coki, returned from comet 81P/Wild 2 in order to relate the time scales of formation of cometary inclusions to their meteoritic counterparts. The data show no evidence of radiogenic {sup 26}Mg and define an upper limit to the abundance of {sup 26}Al at the time of particle formation: {sup 26}Al/{sup 27}Al < 1 x 10-5. The absence of {sup 26}Al indicates that Coki formed >1.7 million years after the oldest solids in the solar system, calcium- and aluminum-rich inclusions (CAIs). The data suggest that high-temperature inner solar system material formed, was subsequently transferred to the Kuiper Belt, and was incorporated into comets several million years after CAI formation.
ISOTOPIC COMPOSITIONS OF URANIUM REFERENCE MATERIALS
Uranium isotopic compositions of a variety of U standard materials were measured at Lawrence Livermore National Laboratory and are reported here. Both thermal ionization mass spectrometry (TIMS) and multi-collector inductively couple plasma mass spectrometry (MC-ICPMS) were used to determine ratios of the naturally occurring isotopes of U. Establishing an internally coherent set of isotopic values for a range of U standards is essential for inter-laboratory comparison of small differences in {sup 238}U/{sup 235}U, as well as the minor isotopes of U. Differences of {approx} 1.3{per_thousand} are now being observed in {sup 238}U/{sup 235}U in natural samples, and may play an important role in understanding U geochemistry where tracing the origin of U is aided by U isotopic compositions. The {sup 238}U/{sup 235}U ratios were measured with a TRITON TIMS using a mixed {sup 233}U-{sup 236}U isotopic tracer to correct for instrument fractionation. this tracer was extremely pure and resulted in only very minor corrections on the measured {sup 238}U/{sup 235}U ratios of {approx} 0.03. The values obtained for {sup 238}U/{sup 235}U are: IRMM184 = 137.698 {+-} 0.020 (n = 15), SRM950a = 137.870 {+-} 0.018 (n = 8), and CRM112a = 137.866 {+-} 0.030 (n = 16). Uncertainties represent 2 s.d. of the population. The measured value for IRMM184 is in near-perfect agreement with the certified value of 137.697 {+-} 0.042. However, the U isotopic compositions of SRM950a and CRM112a are not certified. Minor isotopes of U were determined with a Nu Plasma HR MC-ICPMS and mass bias was corrected by sample/standard bracketing to IRMM184, using its certified {sup 238}U/{sup 235}U ratio. Thus, the isotopic compositions determined using both instruments are compatible. The values obtained for {sup 234}U/{sup 235}U are: SRM950a = (7.437 {+-} 0.043) x 10{sup -3} (n = 18), and CRM112a = (7.281 {+-} 0.050) x 10{sup -3} (n = 16), both of which are in good agreement with published values. The value for {sup 236}U/{sup 235}U in SRM950a was determined to be (8.48 {+-} 2.63) x 10{sup -6}, whereas {sup 236}U was not detected in CRM112a. They are currently obtaining the U isotopic composition of CRM129a. Preliminary results suggest that the {sup 238}U/{sup 235}U ratio is within error, but slightly lower than the certified value of 137.71.