Search NASA⌕ Search

Engineering topics

Hutton, Roger

Publications and source records attributed to Hutton, Roger.

On the fine structure splitting of the 3p{sup 4}3d {sup 4}D{sub 5/2} and 3p{sup 4}3d {sup 4}D{sub 7/2} levels of Fe x

We study UV spectra obtained with the SO82-B slit spectrograph on board SKYLAB to estimate the fine structure (FS) splitting of the Cl-like 3p{sup 4}3d{sup 4}D{sub 5/2} and 3p{sup 4}3d{sup 4}D{sub 7/2} levels of Fe x. The splitting is of interest because the Zeeman effect mixes these levels, producing a “magnetically induced transition” (MIT) from 3p{sup 4}3d{sup 4}D{sub 7/2} to 3p{sup 52}P{sub 3/2}{sup o} for modest magnetic field strengths characteristic of the active solar corona. We estimate the splitting using the Ritz combination formula applied to two lines in the UV region of the spectrum close to 1603.2 Å, which decay from the level 3p{sup 4}({sup 1}D)3d{sup 2}G{sub 7/2} to these two lower levels. The MIT and accompanying spin-forbidden transition lie near 257 Å. By careful inspection of a deep exposure obtained with the S082B instrument, we derive a splitting of ≲7±3 cm{sup −1}. The upper limit arises because of a degeneracy between the effects of non-thermal line broadening and FS splitting for small values of the latter parameter. Although the data were recorded on photographic film, we solved for optimal values of line width and splitting of 8.3 ± 0.9 and 3.6 ± 2.7 cm{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic-level pseudo-degeneracy of atomic levels giving transitions induced by magnetic fields, of importance for determining the field strengths in the solar corona

We present a measured value for the degree of pseudo-degeneracy between two fine-structure levels in Fe{sup 9+} from line intensity ratios involving a transition induced by an external magnetic field. The extracted fine-structure energy difference between the 3p{sup 4}3d{sup 4}D{sub 5/2} and {sup 4}D{sub 7/2} levels, where the latter is the upper state for the magnetic-field induced line, is needed in our recently proposed method to measure magnetic-field strengths in the solar corona. The intensity of the 3p{sup 4}3d{sup 4}D{sub 7/2}→3p{sup 52}P{sub 3/2} line at 257.262 Å is sensitive to the magnetic field external to the ion. This sensitivity is in turn strongly dependent on the energy separation in the pseudo-degeneracy through the mixing induced by the external magnetic field. Our measurement, which uses an Electron Beam Ion Trap with a known magnetic-field strength, indicates that this energy difference is 3.5 cm{sup −1}. The high abundance of Fe{sup 9+} and the sensitivity of the line’s transition probability to field strengths below 0.1 T opens up the possibility of diagnosing coronal magnetic fields. We propose a new method to measure the magnetic field in the solar corona, from similar intensity ratios in Fe{sup 9+}. In addition, the proposed method to use the line ratio of the blended line 3p{sup 4}3d{sup 4}D{sub 7/2,5/2}→3p{sup 52}P{sub 3/2} with another line from Fe x as the density diagnostic should evaluate the effect of the magnetic-field-induced transition line.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel method to determine magnetic fields in low-density plasma facilitated through accidental degeneracy of quantum states in Fe{sup 9+}

We propose a new method to determine magnetic fields, by using the magnetic-field-induced electric dipole transition 3p{sup 4} 3d {sup 4}D{sub 7/2} →3p{sup 5} {sup 2}P{sub 3/2} in Fe{sup 9+} ions. This ion has a high abundance in astrophysical plasma and is therefore well suited for direct measurements of even rather weak fields in, e.g., solar flares. This transition is induced by an external magnetic field and its rate is proportional to the square of the magnetic field strength. We present theoretical values for what we will label the reduced rate and propose that the critical energy difference between the upper level in this transition and the close-to-degenerate 3p{sup 4} 3d {sup 4}D{sub 5/2} should be measured experimentally since it is required to determine the relative intensity of this magnetic line for different magnetic fields.

79 ASTRONOMY AND ASTROPHYSICS↗

A portable high-resolution soft x-ray and extreme ultraviolet spectrometer designed for the Shanghai EBIT and the Shanghai low energy EBITs

A portable high resolution soft x-ray and extreme ultraviolet (EUV) spectrometer has been developed for spectroscopic research at the Shanghai Electron Beam Ion Trap (EBIT) laboratory. A unique way of aligning the grazing incidence spectrometer using the zero order of the grating is introduced. This method is realized by extending the range of the movement of the CCD detector to cover the zero order. The alignment can be done in a few minutes, thus leading to a portable spectrometer. The high vacuum needed to be compatible with the EBITs is reached by mounting most of the translation and rotation stages outside the chamber. Only one high vacuum compatible linear guide is mounted inside the chamber. This is to ensure the convenient interchange of the gratings needed to enable wavelength coverage of the whole range of 10 to 500 Å. Spectra recorded with one of our low energy EBITs shows that a resolving power of above 800 can be achieved. In the slitless configuration used in this work, we found the resolving power to be limited by the width of the EBIT plasma. When mounted on the Shanghai EBIT which is a high energy EBIT and has a narrower EBIT plasma width, the estimated resolving power will be around 1400 at 221.15 Å.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dielectronic recombination studies based on EBIT

Dielectronic recombination (DR) process plays an important role in high temperature plasmas, where DR can affect charge balance and level populations significantly, and can cause radiative energy loss. Resolvable DR sourced satellite lines are often used for plasma temperature diagnostics, while the un-resolvable ones disturb determining spectral line shape, line intensity, and line position. Data of DR resonant strength is vital for accurate modeling of high temperature plasmas. DR studies are also important for testing atomic structure and atomic collision theories, since they carry information on quantum electrodynamics, relativistic effects, electron correlations and so on. Electron beam ion trap (EBIT) is an accelerator type device, which is capable of acting as both ion sources and light sources. EBIT can produce a special sort of plasma, in which electron energy is tunable and has a very narrow distribution. This made it possible for disentanglement studies on electron ion collision processes in plasmas. In this paper, experimental studies of DR processes based on electron beam ion traps (EBIT) will be discussed.

43 PARTICLE ACCELERATORS↗

Simulation studies for operating electron beam ion trap at very low energy for disentangling edge plasma spectra

Electron beam ion traps (EBITs) are very useful tools for disentanglement studies of atomic processes in plasmas. In order to assist studies on edge plasma spectroscopic diagnostics, a very low energy EBIT, SH-PermEBIT, has been set up at the Shanghai EBIT lab. In this work, simulation studies for factors which hinder an EBIT to operate at very low electron energies were made based on the Tricomp (Field Precision) codes. Longitudinal, transversal, and total kinetic energy distributions were analyzed for all the electron trajectories. Influences from the electron current and electron energy on the energy depression caused by the space charge are discussed. The simulation results show that although the energy depression is most serious along the center of the electron beam, the electrons in the outer part of the beam are more likely to be lost when an EBIT is running at very low energy. Using the simulation results to guide us, we successfully managed to reach the minimum electron beam energy of 60 eV with a beam transmission above 57% for the SH-PermEBIT. Ar and W spectra were measured from the SH-PermEBIT at the apparent electron beam energies (read from the voltage difference between the electron gun cathode and the central drift tube) of 60 eV and 1200 eV, respectively. The spectra are shown in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗