Search NASA⌕ Search

Engineering topics

Hyatt, Andrew

Publications and source records attributed to Hyatt, Andrew.

Orion EFT-1 Catalytic Tile Experiment Overview and Flight Measurements

This paper describes the design and results of a surface catalysis flight experiment flown on the Orion Multipurpose Crew Vehicle during Exploration Flight Test 1 (EFT1). Similar to previous Space Shuttle catalytic tile experiments, the present test consisted of a highly catalytic coating applied to an instrumented TPS tile. However, the present catalytic tile experiment contained significantly more instrumentation in order to better resolve the heating overshoot caused by the change in surface catalytic efficiency at the interface between two distinct materials. In addition to collecting data with unprecedented spatial resolution of the "overshoot" phenomenon, the experiment was also designed to prove if such a catalytic overshoot would be seen in turbulent flow in high enthalpy regimes. A detailed discussion of the results obtained during EFT1 is presented, as well as the challenges associated with data interpretation of this experiment. Results of material testing carried out in support of this flight experiment are also shown. Finally, an inverse heat conduction technique is employed to reconstruct the flight environments at locations upstream and along the catalytic coating. The data and analysis presented in this work will greatly contribute to our understanding of the catalytic "overshoot" phenomenon, and have a significant impact on the design of future spacecraft.

Salazar, Giovanni↗

Orion EFT-1 Cavity Heating Tile Experiments and Environment Reconstruction

Developing aerothermodynamic environments for deep cavities, such as those produced by micrometeoroids and orbital debris impacts, poses a great challenge for engineers. In order to assess existing cavity heating models, two one-inch diameter cavities were flown on the Orion Multi-Purpose Crew Vehicle during Exploration Flight Test 1 (EFT1). These cavities were manufactured with depths of 1.0 in and 1.4 in, and they were both instrumented. Instrumentation included surface thermocouples upstream, downstream and within the cavities, and additional thermocouples at the TPS-structure interface. This paper will present the data obtained, and comparisons with computational predictions will be shown. Additionally, the development of a 3D material thermal model will be described, which will be used to account for the three-dimensionality of the problem when interpreting the data. Furthermore, using a multi-dimensional inverse heat conduction approach, a reconstruction of a time- and space-dependent flight heating distribution during EFT1 will be presented. Additional discussions will focus on instrumentation challenges and calibration techniques specific to these experiments. The analysis shown will highlight the accuracies and/or deficiencies of current computational techniques to model cavity flows during hypersonic re-entry.

Salazar, Giovanni↗

Aero-Heating of Shallow Cavities in Hypersonic Freestream Flow

The purpose of these experiments and analysis was to augment the heating database and tools used for assessment of impact-induced shallow-cavity damage to the thermal protection system of the Space Shuttle Orbiter. The effect of length and depth on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These rapid-response experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated immediately prior to the launch of STS-114, the initial flight in the Space Shuttle Return-To-Flight Program, and continued during the first week of the mission. Previously-designed and numerically-characterized blunted-nose baseline flat plates were used as the test surfaces. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process and the two-dimensional flow assumptions used for the data analysis. The experimental boundary layer state conditions were inferred using the measured heating distributions on a no-cavity test article. Two test plates were developed, each containing 4 equally-spaced spanwise-distributed cavities. The first test plate contained cavities with a constant length-to-depth ratio of 8 with design point depth-to-boundary-layer-thickness ratios of 0.1, 0.2, 0.35, and 0.5. The second test plate contained cavities with a constant design point depth-to-boundary-layer-thickness ratio of 0.35 with length-to-depth ratios of 8, 12, 16, and 20. Cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary results indicate that the floor-averaged Bump Factor (local heating rate nondimensionalized by upstream reference) at the tested conditions is approximately 0.3 with a standard deviation of 0.04 for laminar-in/laminar-out conditions when the cavity length-to-boundary-layer thickness is between 2.5 and 10 and for cavities in the depth-to-boundary-layer-thickness range of 0.3 to 0.8. Over this same range of conditions and parameters, preliminary results also indicate that the maximum Bump Factor on the cavity centerline falls between 2.0 and 2.75, as long as the cavity-exit conditions remain laminar. Cavities with length-to-boundary-layer-thickness ratio less than 2.5 can not be easily classified with this approach and require further analysis.

Everhart, Joel L.↗