Documentation of Air Emissions Source Term for Radionuclide NESHAP Compliance: TA-53 Building 0984 Isotope Production Facility

This paper will document the air emissions source term for the TA-53 Building 0984 Isotope Production Facility (IPF). The facility has historically been managed as a minor source under Radionuclide NESHAP regulations, but began using a wider variety of irradiation targets and a higher beam current. To support expanded generation of actinium-225 for medical diagnostic and therapeutic uses, IPF is now irradiating thorium targets and the beam current is planned to increase from 250 microamperes up to 600 microamperes. These changes merit a review of the anticipated source term under the new proposed operational conditions. The end result of the review indicates the main stack (Exhaust Stack ES-1) needs to be managed as a major source with continuous emissions monitoring. No additional advance notifications or permitting is required as a result of these operational changes.

54 ENVIRONMENTAL SCIENCES↗

Stack Test Summary for TA-59-0001

The Radioactive Air Emissions Management (RAEM) team performed stack flow characterization tests at Technical Area (TA) 59 Building 0001 Exhaust Stack (ES) 8. These tests were completed in accordance with Title 40 of the Code of Federal Regulations (CFR), Part 61, Subpart H and the American National Standards Institute (ANSI) N13.1-1999 required by the Clean Air Act. Subpart H of the regulation is the National Emission Standards for Hazardous Air Pollutants (NESHAP) for radionuclides, which compliance with is maintained by the REAM team.

54 ENVIRONMENTAL SCIENCES↗

Annual Performance Testing of Tracer Gas Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP0F 1 regulations is managed by the Radioactive Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniform mixing of tracer gas (sulfur hexafluoride, SF 6 ) and tracer aerosol (liquid oil droplets) in the air stream. This memorandum will specifically focus on the tracer gas portion of the ANSI Standard. For these mix tests, tracer gas is injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of the media concentration must be under 20% when evaluated over the central 2/3 area of the stack or duct.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of Stack Tests at TA-16-Bldg 205: Horizontal Duct on WETF Roof

In late 2023 and early 2024, testing was done at the Weapons Engineering Tritium Facility (WETF) rooftop exhaust duct to verify that the stack sample location was in compliance with the ANSI standard for stack sampling, ANSI N13.1-1999. This ANSI standard is called out by the Clean Air Act rules for airborne radionuclide emissions from DOE facilities, 40 CFR 61 Subpart H. This sample location is designated 16020504, indicating Technical Area 16, Building 0205. The rooftop duct formerly discharged to Exhaust Stack 04, but in 2007 it was re-routed to exhaust out Building 0450, Exhaust Stack 05. For continuity, we have kept the 16020504 designation to represent this duct sample location.

54 ENVIRONMENTAL SCIENCES↗

Flange Tritium Waste Containers Operational Concerns: How to Address the Issues Through the Venting Design

As a part of the U.S. Department of Energy (DOE), Los Alamos National Laboratory (LANL or Laboratory) must comply with regulations in the Clean Air Act (CAA) put forth in 40 Code of Federal Regulations (CFR) 61, Subpart H “National Emission Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities.” The standard states, “Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr [millirem per year] [1].” This regulation is referred to as the National Emission Standards for Hazardous Air Pollutants for Radionuclides (Radionuclide NESHAP or Rad-NESHAP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗