Space Shuttle Solid Rocket Nozzle Joint 2 Gas Path Study
Each Space Shuttle solid rocket nozzle contains five joints. By design, each nozzle joint utilizes room-temperature vulcanized (RTV) rubber as a thermal barrier to protect the nozzle metal parts and O-rings from heat degradation due to motor combustion gas. Typically, combustion gas does not penetrate through the RTV in nozzle Joints. However, Joint currently experiences gas penetration through the RTV over 90 percent of the time. The occurrence of Joint gas paths is a very complex phenomenon with several known contributors such as the unique geometry of the joint, motor pressure, nozzle vectoring, manufacturing induced RTV voids. RTV material capability, and joint skip (relative radial displacement of joint components). The occurrence of Joint gas paths appears to be a combination of these causes. To better understand the causes of gas paths in Joint, the circumferential locations of gas paths in the RTV were identified and correlated with nozzle vectoring, RTV closeour locations (where the RTV backfill is completed), and X-ray low-density. anomaly (LDA) indications. Results that no specific cause was determined.