Search NASA⌕ Search

Engineering topics

Ibrahim, M.

Publications and source records attributed to Ibrahim, M..

Experience With Machine Protection Systems At PIP2IT

The PIP-II Injector Test 1 PIP2IT facility accelerator was assembled in multiple stages in 2014 $-$ 2021 to test concepts and components of the future PIPII linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H$-$ beam to 16 MeV. To protect elements of the beam line, a Machine Protection System MPS was implemented and commissioned. The beam was interrupted faster than 10$\mu$s when excessive beam loss was detected. The paper describes the MPS architecture, methods of the loss detection, procedure of the beam interruption, and operational experience at PIP2IT.

43 PARTICLE ACCELERATORS↗

Thermal Dispersion Within a Porous Medium Near a Solid Wall

The regenerator is a key component to Stirling cycle machine efficiency. Typical regenerators are of sintered fine wires or layers of fine-wire screens. Such porous materials are contained within solid-waH casings. Thermal energy exchange between the regenerator and the casing is important to cycle performance for the matrix and casing would not have the same axial temperature profile in an actual machine. Exchange from one to the other may allow shunting of thermal energy, reducing cycle efficiency. In this paper, temperature profiles within the near-wall region of the matrix are measured and thermal energy transport, termed thermal dispersion, is inferred. The data show how the wall affects thermal transport. Transport normal to the mean flow direction is by conduction within the solid and fluid and by advective transport within the matrix. In the near-wall region, both may be interrupted from their normal in-core pattern. Solid conduction paths are broken and scales of advective transport are damped. An equation is presented which describes this change for a wire screen mesh. The near-wall layer typically acts as an insulating layer. This should be considered in design or analysis. Effective thermal conductivity within the core is uniform. In-core transverse thermal effective conductivity values are compared to direct and indirect measurements reported elsewhere and to 3D numerical simulation results, computed previously and reported elsewhere. The 3-D CFD model is composed of six cylinders in cross flow, staggered in arrangement to match the dimensions and porosity of the matrix used in the experiments. The commercial code FLUENT is used to obtain the flow and thermal fields. The thermal dispersion and effective thermal conductivities for the matrix are computed from the results.

Simon, T.↗

Transition of oscillatory flow in tubes - An empirical model for application to Stirling engines

Attention is given to an empirical model for transition to turbulence in oscillatory flows in straight tubes. Designed after a correlation for transition of a boundary layer on a flat plate, the model yields the laminar flow momentum thickness Reynolds number that must be met before transition to turbulence will occur. The transition point is located by comparing this to the actual momentum thickness Reynolds number. A scheme is proposed for estimating the momentum thickness Reynolds number in terms of the position within the cycle, the maximum value of the diameter Reynolds within the cycle, Re(max), and the dimensionless frequency, Valensi number. Results from an experimental study of oscillatory flow in a tube are employed to develop the model. When the flow is determined to be turbulent, it is proposed that a fully-developed, steady flow friction coefficient be applied. When the flow is laminar, the assumption of fully developed flow cannot be made; thus, a method is suggested for estimating the friction factor.

Simon, T. W.↗

Simulating transitional flow and heat transfer over the flat plate and circular cylinder using a K-epsilon turbulence model

A boundary layer computer code, called TEXSTAN, has been used to simulate external, transitional, fluid flow and heat transfer over the flat plate and circular cylinder. Turbulence modeling was accomplished by using a low-Reynolds number K-epsilon turbulence model. The study was made for free-stream turbulence intensities less than 15 percent. The comparison of the flat plate heat transfer predictions to experimental data showed good agreement, for the location of transition as well as in the heat transfer coefficient. The typical discrepancy in predicting the heat transfer coefficient was less than 5 percent of the measured value.

Sullivan, T. J.↗

Lunar electric fields, surface potential and associated plasma sheaths

A review is given of studies of the electric-field environment of the moon. Surface electric potentials are reported for the dayside and terminator regions, electron and ion densities in the plasma sheath adjacent to each surface-potential regime are evaluated, and the corresponding Debye lengths are estimated. The electric fields, which are approximated by the surface potential over the Debye length, are shown to be at least three orders of magnitude higher than the pervasive solar-wind electric field and to be confined to within a few tens of meters of the lunar surface.

Freeman, J. W.↗