Comment on Free-free opacity in warm aluminum by Vinko et al
Abstract not provided
Engineering topics
Publications and source records attributed to Iglesias, C A.
Abstract not provided
Abstract not provided
A method previously developed to solve large-scale linear systems is applied to statistical Stark broadened line shape calculations. The method is formally exact, numerically stable, and allows optimization of the integration over the quasi-static field to assure numerical accuracy. Furthermore, the method does not increase the computational effort and often can decrease it compared to the conventional approach.
Excited spectator electron effects on Stark broadened spectral line shapes of transitions involving tightly bound electrons are investigated. It is shown that the interference terms in the electron impact broadening are essential to describe the overlapping lines generated by these configurations (e.g.; dielectronic satellite lines). The main impact is narrower spectral features and reduced far wing intensities compared to calculations neglecting the interference terms.
An inverse bremsstrahlung model for plasmas and simple metals that approximates the cold, solid Al experimental data below the L-edge is applied to matter conditions relevant to XUV laser applications. The model involves an all-order calculation using a semi-analytical effective electron-ion interaction. The predicted increases in XUV absorption with rising temperature occur via two effects: increased availability of final states from reduced electron degeneracy and a stronger electron-ion interaction from reduced screening. Discrepancies in the temperature dependence as well as other details between the present approach and a recently proposed absorption model are discussed.
Recent experiments extended iron opacity model tests to temperatures above 150 eV for the first time. The experiments use the Z Facility to volumetrically heat a CH-tamped Fe/Mg plasma using x-rays. The frequency dependent sample transmission is measured by viewing a backlight through the sample. The plasma conditions are inferred from the Mg K-shell absorption. The strategy for this research is to examine the underlying physics within Fe opacity models by comparisons with the measured transmission. Physics topics of interest include charge state distribution, energy level structure, and line broadening. In this talk we discuss methods to exploit the data and advance understanding for these topics. In addition, we review new experiments under way to further improve the data and to achieve higher energy density conditions.
Theoretical opacities are required for calculating energy transport in plasmas. In particular, understanding stellar interiors, inertial fusion, and Z pinches depends on the opacities of mid-atomic-number elements over a wide range of temperatures. The 150-300 eV temperature range is particularly interesting. The opacity models are complex and experimental validation is crucial. For example, solar models presently disagree with helioseismology and one possible explanation is inadequate theoretical opacities. Testing these opacities requires well-characterized plasmas at temperatures high enough to produce the ion charge states that exist in the sun. Typical opacity experiments heat a sample using x rays and measure the spectrally resolved transmission with a backlight. The difficulty grows as the temperature increases because the heating x-ray source must supply more energy and the backlight must be bright enough to overwhelm the plasma self-emission. These problems can be overcome with the new generation of high energy density (HED) facilities. For example, recent experiments at Sandia's Z facility [M. K. Matzen et al., Phys. Plasmas 12, 055503 (2005)] measured the transmission of a mixed Mg and Fe plasma heated to 156{+-}6 eV. This capability will also advance opacity science for other HED plasmas. This tutorial reviews experimental methods for testing opacity models, including experiment design, transmission measurement methods, accuracy evaluation, and plasma diagnostics. The solar interior serves as a focal problem and Z facility experiments illustrate the techniques.
Understanding stellar interiors, inertial confinement fusion, and Z pinches depends on opacity models for mid-Z plasmas in the 100-300 eV temperature range. These models are complex and experimental validation is crucial. In this paper we describe the diagnosis of the first experiments to measure iron plasma opacity at a temperature high enough to produce the charge states and electron configurations that exist in the solar interior. The dynamic Hohlraum x-ray source at Sandia National Laboratories' Z facility was used to both heat and backlight Mg/Fe CH tamped foils. The backlighter equivalent brightness temperature was estimated to be T{sub r}{approx}314 eV{+-}8% using time-resolved x-ray power and imaging diagnostics. This high brightness is significant because it overwhelms the sample self-emission. The sample transmission in the 7-15.5 A range was measured using two convex potassium acid phthalate crystal spectrometers that view the backlighter through the sample. The average spectral resolution over this range was estimated to be {lambda}/{delta}{lambda}{approx}700 by comparing theoretical crystal resolution calculations with measurements at 7.126, 8.340, and 12.254 A. The electron density was determined to be n{sub e}=6.9{+-}1.7x10{sup 21} cm{sup -3} using the Stark-broadened Mg He{beta}, He{gamma}, and He{delta} lines. The temperature inferred from the H-like to He-like Mg line ratios was T{sub e}=156{+-}6 eV. Comparisons with three different spectral synthesis models all have normalized {chi}{sup 2} that is close to unity, indicating quantitative consistency in the inferred plasma conditions. This supports the reliability of the results and implies the experiments are suitable for testing iron opacity models.
The TOPAZ opacity code explicitly includes configuration term structure in the calculation of bound-bound radiative transitions. This approach involves myriad spectral lines and requires the large computational capabilities of parallel processing computers. It is important, however, to make use of these resources efficiently. For example, an increase in the number of processors should yield a comparable reduction in computational time. This proportional 'speedup' indicates that very large problems can be addressed with massively parallel computers. Opacity codes can readily take advantage of parallel architecture since many intermediate calculations are independent. On the other hand, since the different tasks entail significantly disparate computational effort, load-balancing issues emerge so that parallel efficiency does not occur naturally. Several schemes to distribute the labor among processors are discussed.
Over the last several years we have predicted and observed plasmas with an index of refraction greater than one in the soft X-ray regime. These plasmas are usually a few times ionized and have ranged from low-Z carbon plasmas to mid-Z tin plasmas. Our main calculational tool has been the average atom code. We have recently observed C{sup 2+} plasmas with an index of refraction greater than one at a wavelength of 46.9 nm (26.44 eV). In this paper we compare the average atom method, AVATOMKG, against two more detailed methods, OPAL and CAK, for calculating the index of refraction for the carbon plasmas and discuss the different approximations used. We present experimental measurements of carbon plasmas that display this anomalous dispersion phenomenon. It is shown that the average atom calculation is a good approximation when the strongest lines dominate the dispersion. However, when weaker lines make a significant contribution, the more detailed calculations such as OPAL and CAK are essential. During the next decade X-ray free electron lasers and other X-ray sources will be available to probe a wider variety of plasmas at higher densities and shorter wavelengths so understanding the index of refraction in plasmas will be even more essential. With the advent of tunable X-ray lasers the frequency dependent interferometer measurements of the index of refraction may enable us to determine the absorption coefficients and line-shapes and make detailed comparisons against our atomic physics codes.