Search NASA⌕ Search

Engineering topics

Ikeda, S.

Publications and source records attributed to Ikeda, S..

At least 19 records

Performance of a liquid Ga target for Laser Ion Source

We experimentally proved the feasibility of a liquid-based target for Laser Ion Source (LIS) application. The target consists of melted metal gallium contained in a heated crucible. Ions current resulting from laser irradiation. Moreover, given the explosive ablation mechanism involved, each laser shot has been found to induce fluctuations in the surface level. It takes about 0.7 sec to recover the steady condition fully. Despite the maximum fluctuation being 2.7 mm (top-bottom maximum displacement), these fluctuations have shown no significant influence on total ion current and are independent of the temperature of the sample within the tested repetition rate. This study provides valuable insights into the potential of employing such a system for LIS.

43 PARTICLE ACCELERATORS↗

Extraction of ion beam from laser ion source for direct plasma injection scheme

Laser ion sources are expected to be used in various applications of heavy ion beam technology. The plasma direct injection scheme (DPIS) is a method in which ion beams extracted from a laser ion source are directly injected into a radio frequency quadrupole (RFQ) linear accelerator. In this study, a new shape of the plasma electrode with a concave surface for the DPIS was proposed to inject a converging beam to a cavity of RFQ accelerator. This approach allows the use of a large-diameter extraction electrode, which is not limited by the aperture of the RFQ electrode rods. The DPIS, using the concave surface electrode, was employed to accelerate C 6+ ion beams. The results indicated that both the beam current and the number of ions increased nearly twice with the proposed electrode shape compared to values obtained with the conventional electrode. This enhancement corresponded to the increased extraction area of the beam.

43 PARTICLE ACCELERATORS↗

Performance of laser ion source LION operated at Brookhaven National Laboratory

LION is a laser ion source that has been in operation at Brookhaven National Laboratory (BNL) to provide heavy ions for NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). It is the first laser ion source to supply stable ion beams for a long-term operation for users at a large accelerator facility in the world. LION is located at the upstream end of the heavy ion accelerator complex at BNL and supplies singly charged ion beams of various ion species. LION has been in operation since 2014 and is planned to be upgraded in 2024. This paper summarizes the operational performance achieved by LION.

43 PARTICLE ACCELERATORS↗

Progress of the laser ion source upgrade (LION2) for RHIC and NSRL program at Brookhaven National Laboratory

At Brookhaven National Laboratory (BNL), the LION2 ion source is being constructed to replace an existing laser ion ablation ion source (LIS) at the EBIS facility, which provides heavy ion beams of multiple ion species for the operation of NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). The LION1 ion source currently provides singly charged ions of Li, B, C, O, Al, Si, Ca, Ti, Fe, Cu, Zr, Nb, Ag, Tb, Ta, W, Au, Bi, and Th with a rapid-species-change capability. An electron beam ion source, Extended-EBIS captures, confines, and ionizes the ions to high charge state, suitable for injection and acceleration by an RFQ accelerator. Typically, single pulses of the LIS ion species for NSRL are changed sequentially during Galactic Cosmic Ray experiments, while multiple pulses of a given ion beam are provided quasi-simultaneously for RHIC. LION2 will have the same capability of the rapid-species-change with improved beam performance and reliability. LION2 is being constructed in a remote assembly location and is expected to finish in December 2023. The removal of LION1 and installation of LION2 is planned during the December 2023 or summer 2024 shutdown.

43 PARTICLE ACCELERATORS↗

Study on ion current density of different species in laser produced plasma in a solenoid magnet

A solenoid magnetic field along the expanding laser-produced plasma is an essential technique of the laser ion source. The solenoid field can increase ion beam current at beam extraction point by a factor of 2 to over 100 by confining moving laser produced plasma in transverse direction. This technique is used everywhere from development lab to operational machine for user operation. However, the motion of ions in laser produced plasma is not fully understood. In this study, we experimentally investigated the motion of ions in a solenoid magnet (inner diameter 102 mm, coil length 1980 mm) for Al, Fe, and Ta targets. Using the following three conditions: full solenoid bore, a φ51 mm collimator on the solenoid axis, and a thin-wall φ51 mm tube at the bottom of the solenoid, we found that extracting ions at off-axis position (20~30 mm from the solenoid axis in this study) can enhance ion intensity by a factor of three or more. We continue to investigate ion motion in a solenoid field to develop better laser ion source design.

43 PARTICLE ACCELERATORS↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

SYMBA: An end-to-end VLBI synthetic data generation pipeline

Realistic synthetic observations of theoretical source models are essential for our understanding of real observational data. In using synthetic data, one can verify the extent to which source parameters can be recovered and evaluate how various data corruption effects can be calibrated. These studies are the most important when proposing observations of new sources, in the characterization of the capabilities of new or upgraded instruments, and when verifying model-based theoretical predictions in a direct comparison with observational data. We present the SYnthetic Measurement creator for long Baseline Arrays (SYMBA), a novel synthetic data generation pipeline for Very Long Baseline Interferometry (VLBI) observations. SYMBA takes into account several realistic atmospheric, instrumental, and calibration effects. Here, we used SYMBA to create synthetic observations for the Event Horizon Telescope (EHT), a millimetre VLBI array, which has recently captured the first image of a black hole shadow. After testing SYMBA with simple source and corruption models, we study the importance of including all corruption and calibration effects, compared to the addition of thermal noise only. Using synthetic data based on two example general relativistic magnetohydrodynamics (GRMHD) model images of M 87, we performed case studies to assess the image quality that can be obtained with the current and future EHT array for different weather conditions. Our synthetic observations show that the effects of atmospheric and instrumental corruptions on the measured visibilities are significant. Despite these effects, we demonstrate how the overall structure of our GRMHD source models can be recovered robustly with the EHT2017 array after performing calibration steps, which include fringe fitting, a priori amplitude and network calibration, and self-calibration. With the planned addition of new stations to the EHT array in the coming years, images could be reconstructed with higher angular resolution and dynamic range. In our case study, these improvements allowed for a distinction between a thermal and a non-thermal GRMHD model based on salient features in reconstructed images.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of magnetic field fluctuations and diamagnetic currents within a laser ablation plasma interacting with an axial magnetic field

Here, the guiding of laser ablation plasmas with axial magnetic fields has been used for many applications, since its effectiveness has been proven empirically. For more sophisticated and complicated manipulations of the plasma flow, the behavior of the magnetic field during the interaction and the induced diamagnetic current in the plasma plume needs to be clearly understood. To achieve the first milestone for establishing magnetic plasma manipulation, we measured the spatial and temporal fluctuations of the magnetic field caused by the diamagnetic current. We showed that the small fluctuations of the magnetic field can be detected by using a simple magnetic probe. We observed that the field penetrates to the core of the plasma plume. The diamagnetic current estimated from the magnetic field had temporal and spatial distributions which were confirmed to be correlated with the transformation of the plasma plume. Our results show that the measurement by the magnetic probe is an effective method to observe the temporal and spatial distributions of the magnetic field and diamagnetic current. The systematic measurement of the magnetic field variations is a valuable method to establish the magnetic field manipulation of the laser ablation plasma.

43 PARTICLE ACCELERATORS↗

Calcium and lithium ion production for laser ion source

Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗