CAST Technical Bulletin #002: Time Synchronization for Next Generation Power Delivery

This technical bulletin gives a description of the updated effort on Oak Ridge National Laboratory (ORNL) Center for Alternative Synchronization and Timing (CAST) project’s work investigating a terrestrial-based high precision timing infrastructure intended for time synchronization of the next generation power delivery infrastructures. We will provide a high-level description of the CAST application context, key protocols, critical architectural issues, and how GPS/timing data traverse through the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CAST Technical Bulletin #004: Network Time Protocol Introduction

Network Time Protocol (NTP), as it traditionally generated and widely consumed, is a legacy system with known security vulnerabilities. The vulnerabilities can be mitigated by modern implementations of NTP that use internal and external redundancy for better accuracy and fault tolerance. Precision Time Protocol (PTP) is an alternative that uses master clocks inside secure networks to eliminate the known vulnerabilities of NTP.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Needs and Opportunities for Testing of Hydropower Technology Innovations

Despite hydropower’s status as a well-established technology, changes in the global energy sector have prompted a variety of necessary hydropower technological innovations. Examples include efficient lowhead turbines, more flexible and dispatchable hydropower and pumped storage systems to complement variable and intermittent renewable resources, and technologies providing higher environmental performance. However, while innovative technologies are currently being proposed to meet these development challenges, small hydropower facility owners do not have sufficient risk-bearing capacity to adopt new, unvalidated technologies. This discourages manufacturers from bringing nascent technologies to market and stalls the technological growth of the sector. To reduce the risks associated with new technologies and promote further innovation, systemic (and sometimes unconventional) validation activities and new testing capabilities for hydropower are highly desired. These testing capabilities must demonstrate the safety, environmental acceptability, reliability, and performance of innovative technologies to quantify their value compared with existing technologies. Establishing these capabilities through dedicated testing facilities will be key to promoting hydropower growth in the United States. Following direction from the House Energy and Water Development Committee, the US Department of Energy’s Water Power Technologies Office (WPTO) has been tasked with understanding the state of hydropower testing in the United States. This scoping report discusses the needs and opportunities of hydropower testing in the United States, with a specific focus on small hydropower. Future developments will likely mostly target low-head sites with less than 30 ft (9.1 m) from new stream-reach developments, non-powered dam retrofits, and rehabilitation/upgrade of existing plants.

13 HYDRO ENERGY↗

VAC: A Software Approach to Resilient SCADA Automation

To better secure critical infrastructure, especially power systems, this paper introduces a virtual SCADA automation controller. The automation controller is a gateway into a power subsystem, making it a valuable target for cyber-attacks that could cut it off from the control center and cause a loss of view and control. To prevent this, the Virtual Automation Controller (VAC) is a backup device that mirrors the capabilities of the physical controller. It can communicate via Modbus and DNP3 and is containerized so it can be deployed on a variety of platforms. Furthermore, it utilizes software-defined networking to quickly disconnect a failed automation controller and preserve its state for forensics. The VAC gives system operators time to replace the failed controller and prevents dangerous and costly damage to power systems. The VAC is compared against the SEL 3505-3 RTAC and shown to have the necessary features to act as a failover controller.

Johnson, Jordan↗

Tapless Voltage Regulating Transformer. Final Report

Voltage regulation is a common practice in power grid operation. The conventional voltage regulation methods have been facing ever increasing challenges as the penetration of renewable generations deepens in the grid. The intermittent nature of the renewable sources may result in sudden rise or drop of power generation, possibly breaking the generation-load balance. A lack of adequate voltage control not only affects the power quality but is detrimental to the system operation with the potential for large economic losses. Most conventional voltage regulation devices rely on mechanical tap changers to impose the regulation in a step-wise manner. Although sufficient for normal operations, the mechanical tap changers can be easily worn out in the challenging situations created by renewables. In this project, a novel technology called tapless voltage regulating transformer (TAREX) was proposed and investigated. It has the potential to excel at addressing the new voltage regulation challenges and replace the conventional regulating transformers. TAREX is based on the concept of the saturable-core reactor (SCR). The voltage of a TAREX can be smoothly and continuously regulated in a reasonable range by using a low rating power electronics based controller. It uses control of the transformer core magnetization to regulate the voltage on the windings, and thus eliminates the mechanical tap changer. This project is to prove the principle of TAREX, understand the voltage regulation mechanism, and preliminarily understand its impacts on the power systems through modeling, prototyping, and testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using AI Simulations to Dynamically Model Multi-agent Multi-team Energy Systems

The complexity of energy systems is well known as they are complex and intricate systems. As a result, many extant studies have used many simplifications or generalizations that do not accurately reflect the nature of this complex system. In particular, most HVAC systems are modeled as a single unit, or several large units, rather than as a hierarchical composite (e.g., as a floor rather than as a collection of disparate rooms). The net result of this is that the simulations are too generic to perform meaningful analysis, machine learning, or integrated simulation. We propose using a multi-agent multi-team strategic simulations framework called SiMAMT to better define, model, simulate, and learn the HVAC environment. SiMAMT allows us to create distinct models for each type of room, hierarchically aggregate them into units (like floors, or sections), and then into larger sets (like buildings or a campus), and then perform a simulation that interacts with each sub-element individually, the teams of sub-elements collectively, and the entire set in aggregation. Further, and most importantly, we additionally model another ‘team’ within the simulation framework - the users of the systems. Again, each individual is modeled distinctly, aggregated into sub-sets, then collected into large sets. Each user, or agent, is performing on their own but with respect to the larger team goals. This provides a simulation that has a much higher model fidelity and more applicable results that match the real-world.

Franklin, D. Michael↗

Report on Oak Ridge National Laboratory Testing of Ambient Cure TransPowr E3X®

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductor and conductor instrumentation under field conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr® with Ambient Cure E3X™ Technology—a standard overhead conductor with a high emissivity, low absorptivity ambient cure surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures with respect to uncoated conductor of the same type, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practice Summary: Improved Reliability via Optimization in Residential Microgrids

Southern Company is an electric utility that is embracing residential microgrids as a platform for distributed energy. The first residential microgrid in the southeastern United States was constructed in Hoover, Alabama, as a testbed for development. To operate the microgrid, we developed an optimization model for unit commitment and economic dispatch. We report the optimization model was implemented in a microgrid central controller and tested under various operational scenarios. Challenges also include developing a pricing algorithm to deliver price forecasts to the residential homes in the microgrid and open-source software restrictions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On the Effectiveness of Recurrent Neural Networks for Live Modeling of Cyber-Physical Systems

Attention to cyber security of cyber-physical systems (CPS) has led to the development of innovative cyber-resilient methodologies to ensure early detection and mitigation of cyber anomalies and threats. The concept of Digital Twin (DT) has recently emerged as one of the approaches to achieve the objective of resilience. In the approach using DT, a software-based live model of a target CPS is used to continuously monitor, surveil and verify the correctness of the target CPS operation. In this paper, we empirically study the effectiveness of Recurrent Neural Network (RNN)-based models as the basis of DT-based resilience. We uncover the important characteristics of an RNN-based solution with experimentation on a lab-scale Canal Lock CPS emulator with live validations and attack scenarios. For the first time, we demonstrate actual, real-time use of a RNN-based model as a DT for performing live analysis on an operational CPS. Based on the observed results, we highlight the importance of a DT model's training interval, prediction interval and CPS polling interval in the process of anomaly detection. We uncover the limitations in anomaly detection due to real-time synchronization needs of the RNN-based DT. We highlight this uncovered tug of war between synchronization and anomaly detection is inherent in any complex CPS that is monitored and synchronized by relying on the same sensor streams of ground truth for both synchronization as well as anomaly detection.

Yoginath, Srikanth↗

GMLC Southeast Regional Consortium: Technology Driven Improvements to Power Grid Resiliency

Recognizing that electric grid challenges can differ by geographical regions across the US, the Department of Energy (DOE) created a pioneer regional partnership to provide technical assistance to stakeholders facing grid modernization challenges. The southeast regional teams will transfer technologies developed under DOE auspices to stakeholders for testing, evaluation, and market validation. Regional members will help define critical challenges and pave the way for transition of technologies to the commercial sector. Using the depth and expertise at Oak Ridge National Laboratory, Savannah River National Laboratory, University of Tennessee’s CURENT, CAPER and the Clemson 20 MVA Electrical Grid Laboratory—along with critical industry partners, such as Duke Energy, TVA, Southern Company, EPB, and Santee Cooper—the Southeast Regional Consortium team will conduct collaborative research to advance the state of the grid in the Southeast region and improve power system resiliency to enhance responsiveness, enable faster restoration of power, and increase distributed energy resource (DER) concentrations. This report provides details of the technical research and demonstration projects accomplished by Oak Ridge National Laboratory (ORNL) as part of the Southeast Regional Consortium. Specifically, ORNL analyzed the application of optical current and voltage measurements impedance relays which would enable step distance protection to be deployed on distribution systems. This would improve the precision of determining the geographic location of faults, increase network topology flexibility, and allow bi-directional power flow. Next, ORNL deployed time sensitive networking technology on the EPB fiberoptic data network to study the impact of increased sensor traffic on existing supervisory control and data acquisition data. The deterministic latency and high bandwidth were demonstrated by remotely inspecting a substation using a drone with full HD streaming video operated at the EPB Control Center. Finally, a new application-based communication and control system developed at ORNL call CSEISMIC was tested for future deployment on the EPB Control Center microgrid using a hardware-in-the-loop testbed that was also developed at ORNL. The controller was able to successfully optimize ancillary service when the microgrid is connected to the distribution network. The seamless islanding, resynchronization, and reconnection of the microgrid was also demonstrated through the testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report on Oak Ridge National Laboratory Testing of Southwire 795 C7 Round Wire

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductors and conductor instrumentation under field conditions. PCAT is set up to capture large amounts of data during testing.

36 MATERIALS SCIENCE↗

Preliminary Report on Oak Ridge National Laboratory Testing of Drake/ACSS/MA2/E3X

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of a new conductor technology under real world conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr with E3X Technology a standard overhead conductor with an inorganic high emissivity, low absorptivity surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides initial results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Energy Storage Management in Distribution Network

With increasing penetration of distributed generation (DG) in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. In this paper, an iterative mixed integer quadratic constrained quadratic programming model to optimize the operation of a three phase unbalanced distribution system with high penetration of Photovoltaic (PV) panels, DG and energy storage (ES) is developed. The proposed model minimizes not only the operating cost, including fuel cost and purchasing cost, but also voltage deviations and power loss. The optimization model is based on the linearized sensitivity coefficients between state variables (e.g., node voltages) and control variables (e.g., real and reactive power injections of DG and ES). To avoid slow convergence when close to the optimum, a golden search method is introduced to control the step size and accelerate the convergence. The proposed algorithm is demonstrated on modified IEEE 13 nodes test feeders with multiple PV panels, DG and ES. Numerical simulation results validate the proposed algorithm. Various scenarios of system configuration are studied and some critical findings are concluded.

linearization↗

Development of Hardware-in-the-loop Microgrid Testbed

A hardware-in-the-loop (HIL) microgrid testbed for the evaluation and assessment of microgrid operation and control system has been presented in this paper. The HIL testbed is composed of a real-time digital simulator (RTDS) for modeling of the microgrid, multiple NI CompactRIOs for device level control, a prototype microgrid energy management system (MicroEMS), and a relay protection system. The applied communication-assisted hybrid control system has been also discussed. Results of function testing of HIL controller, communication, and the relay protection system are presented toshow the effectiveness of the proposed HIL microgrid testbed.