Search NASA⌕ Search

Engineering topics

Irvine, Sawyer B.

Publications and source records attributed to Irvine, Sawyer B..

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Development of Laser-Induced Breakdown Spectroscopy for the Californium-252 Supply Program

Calibration-free–laser-induced breakdown spectroscopy (CF-LIBS) is suggested as an alternative to traditional LIBS because it does not rely on calibration curves and instead relies on previously reported parameters called transition probabilities. Transition probabilities are fundamental parameters that describe the probability a specific transition from an upper energy to a lower energy will occur. These values act as internal calibrations and allow concentrations to be calculated based on the plasma temperature and electron density, which can be determined from Saha-Boltzmann methods. CF-LIBS provides the ability to perform elemental concentration estimations on samples without the need for chemical dilutions and only nanograms of material are ablated into the plasma. These benefits can be applied remotely inside hot cells, glove boxes, and radiation hoods through optical fibers. This report summarizes recent efforts to develop CF-LIBS methods for future applications within Oak Ridge National Laboratory’s radioisotope production portfolio, such as the Cf-252 Supply Program. Summaries are provided for the developed Python scripts for data analysis and two studies employing these programs to determine unreported transition probabilities of relevant lanthanides. Additionally, a review of fiber-delivered LIBS and a discussion of a LIBS fiber probe design are provided.

07 ISOTOPE AND RADIATION SOURCES↗