Search NASA⌕ Search

Engineering topics

Irwin, J

Publications and source records attributed to Irwin, J.

SU-F-T-509: Investigation into the Impact of the Linear Accelerator Treatment Table On Skin Dose to Prone Breast Patients

Purpose: To investigate the impact of the treatment table on skin dose for prone breast patients for which the breast contacts the table and to develop a method to decrease skin dose. Methods: We used 12cm stack of 15cmx15cm solid water slabs to imitate breast. Calibrated EBT3 radiochromic film was affixed to the bottom of the phantom. Treatments for 32 patients were analyzed to determine typical prone breast beam parameters. Based on the analysis, a field size and a range of gantry angles were chosen for the test beams. Three experimental setups were used. The first represented the patient setup currently used in our clinics with the phantom directly on the table. The second was the skin sparing setup, with a 1.5cm Styrofoam slab between the phantom and the table. The third used a 7.5cm Styrofoam slab to examine the extent of skin sparing potential. The calibration curve was applied to each film to determine dose. Percent difference in dose between the current and skin sparing setups was calculated for each gantry angle and gantry angle pair. Results: Data showed that beams entering through the table showed a skin dose decrease ranging from 13%–30% with the addition of 7.5cm Styrofoam, while beams exiting through the table showed no significant difference. The addition of 1.5cm Styrofoam resulted in differences ranging from 0.5%–13% with the skin sparing setup. Conclusion: The results demonstrate that skin in contact with the table receives increased dose from beams entering through the table. By creating separation between the breast and the table with Styrofoam the skin dose can be lowered, but 1.5 cm did not fully mitigate the effect. Further investigation will be performed to identify a clinically practical thickness that maximizes this mitigation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-246: Detector Selection for Small Field Measurements, a Comparative Study

Purpose: To compare commercially available detectors for small field dosimetry. Methods: PTW (Freiburg, Germany) diode E, PTW microDiamond, and SunNuclear (Melbourne, FL) Edge detector were used to measure output factors, PDD, and profiles on a Varian iX linear accelerator (Varian Medical Systems, Palo Alto, CA) using 6MV and 18MV photon beams. The water tank was set to 100cm SSD. Centering profiles at 5cm and 20cm depth confirmed an offset <0.1mm. High resolution PDD (0.1mm) aligned the collecting volume at water surface. For setup and linearity verification, PDD and profiles were matched to annual measurements, which were performed with an A1SL ion chamber.Scans were taken for 6X and 18X, for 10cmx10cm, 10cmx2cm, 10cmx1cm, and 10cmx0.5cm fields. Profiles were measured at Dmax (6X=1.5cm, 18X=3.5cm), 5cm, 10cm, and 20cm depths. All fields used 10cmx10cm jaws with the MLC defining the field in the X-direction. PDDs used 2mm step size and 0.2s discrete collecting time. Profiles used 1mm step size and a 0.4s discrete collecting time. Results: The PTW diode E and Edge detector exhibit centering stability, but all detectors require vertical shifts from Vendor defined vertical alignment. Output factor measurements reveal good agreement between detectors. The Edge detector demonstrates the sharpest penumbra and the closest consistent match to ion chamber measurements in the out of field regions for 6MV (3.2%). Each detector provides comparable curve quality for PDDs, with a maximum difference across detectors giving a standard deviation of 0.6% at 30cm depth, 18X, and 10cmx0.5cm. Profiles match closely across all detectors, depths, energies, and field sizes. The microDiamond detector produces the largest penumbra width, largest deviation from ion chamber dose in the tail region for 6MV, and exhibits centering instability. Conclusion: Based on our findings, the Edge detector was chosen for stereotactic measurements. The PTW diode E is an acceptable alternative.

60 APPLIED LIFE SCIENCES↗

An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

43 PARTICLE ACCELERATORS↗

Parameters for the PEP-II B-Factory at SLAC in 2008

The PEP-II B-Factory at SLAC (3.1 GeV e{sup +} x 9.0 GeV e{sup -}) operated from 1999 to 2008, delivering luminosity to the BaBar experiment. The design luminosity was reached after one and a half years of operation. In the end PEP-II surpassed, by four times, its design luminosity reaching 1.21 x 10{sup 34} cm{sup -2}s{sup -1}. It also set world stored beam current records of 2.1 A e{sup -} and 3.2 A e{sup +}. Continuous injection was implemented with BaBar successfully taking data. The total delivered luminosity to the BaBar detector was 557.4 fb{sup -1} spanning five upsilon resonances. PEP-II was constructed by SLAC, LBNL, and LLNL with help from BINP, IHEP, the BaBar collaboration, and the US DOE OHEP.

43 PARTICLE ACCELERATORS↗

PERIODIC RADIO EMISSION FROM THE M7 DWARF 2MASS J13142039+1320011: IMPLICATIONS FOR THE MAGNETIC FIELD TOPOLOGY

We present multi-epoch radio and optical observations of the M7 dwarf 2MASS J13142039+1320011. We detect a {approx}1 mJy source at 1.43, 4.86, 8.46, and 22.5 GHz, making it the most luminous radio emission over the widest frequency range detected from an ultracool dwarf to date. A 10 hr Very Large Array observation reveals that the radio emission varies sinusoidally with a period of 3.89 {+-} 0.05 hr, and an amplitude of {approx}30% at 4.86 GHz and {approx}20% at 8.46 GHz. The periodicity is also seen in circular polarization, where at 4.86 GHz the polarization reverses helicity from left- to right-handed in phase with the total intensity. An archival detection in the Faint Images of the Radio Sky at Twenty Centimeters survey indicates that the radio emission has been stable for at least a decade. We also detect periodic photometric variability in several optical filters with a period of 3.79 hr and measure a rotation velocity of vsin i = 45 {+-} 5 km s{sup -1}, in good agreement with the radio and optical periods. The subtle difference in radio and optical periods may be due to differential rotation, with {Delta}{Omega} {approx} 1 rad day{sup -1} between the equation and poles. The period and rotation velocity allow us to place a lower limit on the radius of the source of {approx}> 0.13R{sub sun}, about 30% larger than theoretical expectations. The properties of the radio emission can be explained with a simple model of a magnetic dipole misaligned relative to the stellar rotation axis, with the sinusoidal variations and helicity reversal due to the rotation of the magnetic poles relative to our line of sight. The long-term stability of the radio emission indicates that the magnetic field (and hence the dynamo) is stable on a much longer timescale than the convective turnover time of {approx}0.2 yr. If the radio emission is due to gyrosynchrotron emission the inferred magnetic field strength is {approx}0.1 kG, while the electron cyclotron maser process requires a field of at least 8 kG.

79 ASTRONOMY AND ASTROPHYSICS↗

WASP-22 b: A TRANSITING 'HOT JUPITER' PLANET IN A HIERARCHICAL TRIPLE SYSTEM

We report the discovery of a transiting planet orbiting the star TYC 6446-326-1. The star, WASP-22, is a moderately bright (V = 12.0) solar-type star (T{sub eff} = 6000 {+-} 100 K, [Fe/H] = -0.05 {+-} 0.08). The light curve of the star obtained with the WASP-South instrument shows periodic transit-like features with a depth of about 1% and a duration of 0.14 days. The presence of a transit-like feature in the light curve is confirmed using z-band photometry obtained with Faulkes Telescope South. High-resolution spectroscopy obtained with the CORALIE and HARPS spectrographs confirms the presence of a planetary mass companion with an orbital period of 3.533 days in a near-circular orbit. From a combined analysis of the spectroscopic and photometric data assuming that the star is a typical main-sequence star we estimate that the planet has a mass M{sub p} = 0.56 {+-} 0.02M{sub Jup} and a radius R{sub p} = 1.12 {+-} 0.04R{sub Jup}. In addition, there is a linear trend of 40 m s{sup -1} yr{sup -1} in the radial velocities measured over 16 months, from which we infer the presence of a third body with a long-period orbit in this system. The companion may be a low mass M-dwarf, a white dwarf, or a second planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Beam Beam Simulation Studies for NLC And SLC2000

We apply and modify the computer codes CAIN(P.Chen, G.Horton-Smith, T.Ohgaki, A.W.Weidemann, K.Yokoya, contributed to Workshop on Gamma-Gamma Colliders, Berkeley, CA, March 28-31, 1994; SLAC-PUB-6583.) and GUINEAPIG(D.Schulte (DESY), unpublished.) to make detailed studies of the beam-beam interaction in the SLAC design for a future linear collider (NLC), as well as to the proposed SLC2000 project. Using realistic beam distributions, we present simulations related to the tuning and optimization of luminosity in SLC2000 and NLC.

43 PARTICLE ACCELERATORS↗

WASP-16b: A NEW JUPITER-LIKE PLANET TRANSITING A SOUTHERN SOLAR ANALOG

We report the discovery from WASP-South of a new Jupiter-like extrasolar planet, WASP-16b, which transits its solar analog host star every 3.12 days. Analysis of the transit photometry and radial velocity spectroscopic data leads to a planet with R{sub p} = 1.008 +- 0.071 R{sub Jup} and M{sub p} = 0.855 +- 0.059 M{sub Jup}, orbiting a host star with R {sub *} = 0.946 +- 0.054 R{sub sun} and M{sub *} = 1.022 +- 0.101 M{sub sun}. Comparison of the high resolution stellar spectrum with synthetic spectra and stellar evolution models indicates the host star is a near-solar metallicity ([Fe/H] =0.01 +- 0.10) solar analog (T{sub eff} = 5700 +- 150 K and log g = 4.5 +- 0.2) of intermediate age (tau = 2.3{sup +5.8}{sub -2.2} Gyr).

79 ASTRONOMY AND ASTROPHYSICS↗

THE LOW DENSITY TRANSITING EXOPLANET WASP-15b

We report the discovery of a low-density exoplanet transiting an 11th magnitude star in the Southern hemisphere. WASP-15b, which orbits its host star with a period P = 3.7520656 {+-} 0.0000028 d, has a mass M {sub p} = 0.542 {+-} 0.050 M {sub J} and radius R {sub p} = 1.428 {+-} 0.077 R {sub J}, and is therefore one of the least dense transiting exoplanets so far discovered ({rho}{sub p} = 0.247 {+-} 0.035 g cm{sup -3}). An analysis of the spectrum of the host star shows it to be of spectral type around F5, with an effective temperature T {sub eff} = 6300 {+-} 100 K and [Fe/H] = -0.17 {+-} 0.11.

79 ASTRONOMY AND ASTROPHYSICS↗