Investigation Of Epoxy Curing
Kinetic model describes major features of curing process. Report describes investigation of curing of epoxy resin used in carbon-fiber/epoxy version of cases of Space Shuttle booster rockets.
Engineering topics
Publications and source records attributed to Islas, A..
Kinetic model describes major features of curing process. Report describes investigation of curing of epoxy resin used in carbon-fiber/epoxy version of cases of Space Shuttle booster rockets.
An epoxy and carbon fiber composite has been used to produce a light-weight rocket case for the Space Shuttle. A kinetic model is developed which can predict the extent of epoxy conversion during the winding and curing of the case. The model accounts for both chemical and physical kinetics. In the model, chemical kinetics occur exclusively up to the time the transition temperature equals the reaction temperature. At this point the resin begins to solidify and the rate of this process limits the rate of epoxy conversion. A comparison of predicted and actual epoxy conversion is presented for isothermal and temperature programmed cure schedules.
The effects on reaction time and behavior were studied for exposure to reduced oxygen concentrations in the presence and absence of carbon monoxide. Tests were run with Swiss Webster mice in a pole-jump apparatus. The results show that reaction times increase gradually with a decrease in oxygen (O2) to 10 percent O2. Below 10 percent O2 reaction times increase dramatically and performance is degraded almost immediately. At carbon monoxide (CO) concentrations of 500 ppm and reduced O2 levels, reaction times are increased even more. At CO concentrations of 1000 ppm, performance is nearly completely degraded even without reduced oxygen levels.
A mathematical model is developed for predicting blood concentrations of cyanide as functions of exposure time to constant levels of cyanide in the atmosphere. A toxic gas (which may form as a result of decomposition of combustion materials used in transportation vehicles) is breathed into the alveolar space and transferred from the alveolar space to the blood by a first-order process, dependent on the concentration of the toxicant in the alveolar space. The model predicts that blood cyanide levels are more sensitive to the breathing cycle than to blood circulation. A model estimate of the relative effects of CO and HCN atmospheres, generated in an experimental chamber with an epoxy polymer, shows that toxic effects of cyanide occur long before those of carbon monoxide.