Search NASA⌕ Search

Engineering topics

Itay, R.

Publications and source records attributed to Itay, R..

39 records · Page 3

First Measurement of Differential Charged Current Quasielasticlike $\nu_{\mu}$ -Argon Scattering Cross Sections with the MicroBooNE Detector

We report on the first measurement of flux-integrated single differential cross sections for charged-current (CC) muon neutrino ($\nu_{\mu}$) scattering on argon with a muon and a proton in the final state, 40 Ar $(\nu_{\mu},μp)X$. The measurement was carried out using the Booster Neutrino Beam at Fermi National Accelerator Laboratory and the MicroBooNE liquid argon time projection chamber detector with an exposure of 4.59 × 10 19 protons on target. Events are selected to enhance the contribution of CC quasielastic (CCQE) interactions. The data are reported in terms of a total cross section as well as single differential cross sections in final state muon and proton kinematics. We measure the integrated per-nucleus CCQE-like cross section (i.e., for interactions leading to a muon, one proton, and no pions above detection threshold) of (4.93 ± 0.76 stat ± 1.29 sys )×10 -38 cm 2 , in good agreement with theoretical calculations. The single differential cross sections are also in overall good agreement with theoretical predictions, except at very forward muon scattering angles that correspond to low-momentum-transfer events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗