Search NASA⌕ Search

Engineering topics

Iwai, H

Publications and source records attributed to Iwai, H.

Development of neutron spectrometer toward deuterium plasma diagnostics in LHD

Neutron spectrometer based on coincident counting of associated particles has been developed for deuterium plasma diagnostics on Large Helical Device (LHD) at the National Institute for Fusion Science. Efficient detection of 2.5 MeV neutron with high energy resolution would be achievable by coincident detection of a scattered neutron and a recoiled proton associated with an elastic scattering of incident neutron in a plastic scintillator as a radiator. The calculated neutron spectra from deuterium plasma heated by neutral beam injection indicate that the energy resolution of better than 7% is required for the spectrometer to evaluate energetic deuterium confinement. By using a prototype of the proposed spectrometer, the energy resolution of 6.3% and the detection efficiency of 3.3x10{sup -7} count/neutron were experimentally demonstrated for 2.5 MeV monoenergetic neutron, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photochromism and visible light induced H{sub 2} generation in Sr{sub 2}TiO{sub 4}:Cr complexes

Sr{sub 2}TiO{sub 4}:Cr complexes are found to possess photochromism. After the photochromism, the catalytic performance of the complexes for H{sub 2} generation increases markedly. In fact, it was found that the performance increased more than 20 times compared to the original Sr{sub 2}TiO{sub 4}: 10 mol % Cr complex. These results suggest that it is worthwhile searching and optimizing visible-light-sensitive photocatalysts by investigating possible photochromism.

07 ISOTOPE AND RADIATION SOURCES↗

Three dimensional image construction and spectrum extraction from two dimensional elemental mapping in Auger electron spectroscopy

Three dimensional Auger elemental distributions have been constructed from the combination of high spatial resolution, two dimensional Auger maps obtained at multiple sputter depths. These three dimensional elemental distributions have been used to compare the interfacial regions for two kinds of silicon on insulator wafers. It is clearly seen that silicon oxide is formed as an island structure for the SIMOX specimen, whereas the UNIBOND specimen has a featureless structure at the Si/SiO{sub 2} interface. Linear least squares fitting from several two dimensional maps obtained at different energies have been used to produce energy dispersive spectra from specific regions of high spatial resolution Auger maps. This technique was used to examine the interface region exposed from sputter craters through a silicon dioxide layer on a silicon substrate and through a Ni silicide film on a silicon substrate. The Si LVV spectra for the elemental silicon, oxide, and silicide components extracted from the multiple energy two dimensional maps can be used to map the chemical components in the interfacial regions.

36 MATERIALS SCIENCE↗