Search NASA⌕ Search

Engineering topics

Jackson, Timothy

Publications and source records attributed to Jackson, Timothy.

Experimental Testing of Personal Dosimetry Interference from a Portable X-ray Generator

The determination of the disposition route for a legacy drum in a nuclear facility at the Y-12 National Security Complex is supported by non-destructive testing of the drum and its contents. An advanced radiation measurements organization at the Y-12 National Security Complex proposed a series of active measurements using a portable x-ray generator, imaging the drum and its contents with 360-degree visualization. In rooms near the current storage location for the drum, Criticality Accident Alarm System (CAAS) annunciation is degraded, and Personal Radiation Dosimetry Instruments (PRDI’s) are routinely worn by personnel. The Y-12 Development Organization has procured advanced radiation detection devices and a variety of radiation sources for use in active measurements. These devices are being used to support Y-12 operations and safety engineering disciplines to safely address complex challenges throughout the complex. This paper presents the results of experimental testing of the PRDI’s used at Y-12 with the x-ray generator [1], and notes the unique utilization of a decommissioned facility for this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of the ANSI/ANS-8.3-2022 Minimum Accident to Tube Vault Storage

In support of planned site activities, the existing basis for criticality safety in nuclear facilities is being revisited. One such technical basis is the demonstration of Criticality Accident Alarm System (CAAS) coverage in tube vaults at Y-12 National Security Complex. The configuration of the vaults places significant shielding between the source and the detector stations and is dissimilar to drum storage or other processes. This paper describes tube vault storage at Y-12, describes the basis for the application of the 2022 minimum accident for system design (MASD) to the analysis, and presents how the accident is implemented in the analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

Goals: 1) Qualify the CAAS-3S system to a mixed-field radiation dose and dose rate, and 2) Extend the Y-12 Shielding MCNP Validation to rad-si. This paper represents the efforts of Y-12 and UPF personnel, and their interpretation of the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

The Y-12 National Security Complex and the Uranium Processing Facility (UPF) selected the Mirion CAAS-3S as the Criticality Accident Alarm System for UPF and for Y-12 facilities replacing their legacy CAAS as part of efforts to extend the facility lifespans. As part of this process, the CAAS-3S system was exposed to a high radiation dose and dose rate during reactor testing with the Godiva-IV fast burst reactor. The reactor testing was designed around preliminary analyses that determined Y-12 and UPF requirements, and simulations of the radiation field within the reactor facility were used to determine reactor operating parameters, CAAS equipment locations, and the design of a neutron shield wall. This paper presents the design and results of the testing, and discusses how the test results were interpreted by criticality safety engineers at Y-12 and UPF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Need for a Maximum Intensity Accident in ANS 8-Series Standards

Y-12 has installed one CAAS system under the ANS 8.3 framework as a safety significant system, and is in the process of designing, installing, and qualifying another. As a safety significant system, the Y-12 CAAS is required to demonstrate that it is able to perform its function and actuate an alarm when exposed to the radiation from both a Minimum Accident of Concern and a maximum intensity accident. The ANS 8-series standards do not present a maximum accident to be considered, nor do they specify dose rate tolerance requirements, leading CAAS vendors to potentially use other standards that provide inadequate criteria. A maximum intensity accident is proposed, and the effects of this accident on CAAS analysis and the vendor’s equipment qualification are discussed

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Need for a Maximum Intensity Accident in ANS 8-Series Standards

The Y-12 National Security Complex has installed one Criticality Accident Alarm System (CAAS) under the ANS 8.3 framework as a safety significant system, and is in the process of designing, installing, and qualifying another. As a safety significant system, the Y-12 CAAS is required to demonstrate that it is able to perform its function and actuate an alarm when exposed to the radiation from both a Minimum Accident of Concern and a maximum intensity accident. The ANS 8-series standards do not present a maximum accident to be considered, nor do they specify radiation tolerance requirements for the CAAS equipment, leading CAAS vendors to potentially use other standards that provide inadequate criteria. In this paper, the historical basis and need for a maximum intensity accident in the ANS standards is discussed, the fission rate of a maximum intensity accident is proposed, and the effects of this accident on CAAS analysis and the vendor’s equipment qualification are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calendar Year 2009 Annual Site Environmental Report for Sandia National Laboratories, New Mexico

Sandia National Laboratories, New Mexico (SNL/NM) is a government-owned/contractor operated facility. Sandia Corporation (Sandia), a wholly owned subsidiary of Lockheed Martin Corporation (LMC), manages and operates the laboratory for the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA). The DOE/NNSA, Sandia Site Office (SSO) administers the contract and oversees contractor operations at the site. This annual report summarizes data and the compliance status of Sandia Corporation’s environmental protection and monitoring programs through December 31, 2009. Major environmental programs include air quality, water quality, groundwater protection, terrestrial surveillance, waste management, pollution prevention (P2), environmental restoration (ER), oil and chemical spill prevention, and implementation of the National Environmental Policy Act (NEPA). Environmental monitoring and surveillance programs are required by DOE Order 450.1A, Environmental Protection Program (DOE 2008a) and DOE Manual 231.1-1A, Environment, Safety, and Health Reporting (DOE 2007).

54 ENVIRONMENTAL SCIENCES↗