Search NASA⌕ Search

Engineering topics

Jahrman, Evan P.

Publications and source records attributed to Jahrman, Evan P..

Plastic-waste hydrogenolysis over two-dimensional MXene-supported ruthenium catalysts with tunable interlayer spacing

The hydrogenolysis of plastics is limited by active-site inaccessibility and inefficient mass transport of bulky polymer chains. To overcome these challenges, this work developed two-dimensional MXene-supported Ru (Ru@MXene) catalysts. Lyophilization of a solution containing dispersed MXene sheets and Ru precursors enabled the confinement of Ru species within the MXene interlayers, which act as pillars to expand the interlayer spacing. Building on this, a silica-pillared MXene-supported Ru (Ru@P-MXene) with even larger interlayer spacing exhibited a reaction rate of 914.9 g C5–C35 g Ru –1 h –1 for the hydrogenolysis of low-density polyethylene (LDPE) into valuable liquid chemicals (e.g., C 5 –C 35 ). A comparison of product yields between Ru@P-MXene and Ru@MXene suggests that elongated Ru particles confined within the MXene support expose their side facets for the reaction. In conclusion, this work demonstrates a new application of MXene in thermochemical catalysis, offering a solution to the challenges of active-site accessibility, mass transport, and reaction confinement in chemical plastic upcycling.

2D materials↗

Effect of chlorine and chromium on sulfur solubility in low-activity waste glass

According to an empirical sulfur solubility model developed from over 200 simulated low-activity waste (LAW) glasses, chlorine and chromium show strong effects on lowering sulfur solubility in glass. This work was aimed at understanding the mechanism behind the negative effect of chlorine and chromium on sulfur solubility. A simplified LAW glass was prepared and saturated by sodium sulfate, sodium chloride, and sodium chromate salts as single components and as mixtures with different ratios at 25 mol%, 50 mol%, and 75 mol% of sulfate mixed with chloride or chromate. A crucible-scale salt-saturation was performed by mixing the crushed glass powder with an excess amount of salts, melting at 1150 °C for one hour, and quenching. Three mixing-melting-quenching cycles were applied to determine saturation concentrations of sulfur, chromium, and chlorine incorporated into the simplified LAW glass. The glass compositions were analyzed by inductively coupled plasma–atomic emission spectroscopy, ion chromatography, and X-ray emission spectroscopy. It is proposed that the negative effect of chlorine and chromium on sulfur solubility can be explained based on the simple hypothesis that sulfur, chlorine, and chromium are present in the glass as anions competing for the voids or interstitial sites of the glass matrix, and that their solubility strongly depends on the effective size of corresponding anions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Valence-to-core X-ray emission spectroscopy of vanadium oxide and lithiated vanadyl phosphate materials

In this work, we report valence-to-core (VTC) X-ray emission spectroscopy (XES) measurements and theoretical calculations of the electrochemical sequence ε-VOPO 4 , ε-LiVOPO 4 , ε-Li 2 VOPO 4 and the reference oxides V 2 O 3 , VO 2 , and V 2 O 5 . In our analysis of these results, we establish a framework for interrogating chemical bonding that is generally applicable to a wide range of systems, including complex, extended inorganic compounds. While this latter regime has garnered less focused application than, e.g. , metalloenzymes in many excellent catalysis studies, we show that the technique provides high utility in materials-focused energy storage research. Here, sensitivities to the local atomic structure and hybridization schemes are discussed in detail. Similarly, the effect of lithiation on oxidation, delocalization, and shifts in ligand valence energy levels are all readily apparent in the analyzed results. Finally, the TDDFT projections clearly reveal the directional dependencies of the valence band at each of the vanadium sites. Our results demonstrate laboratory-based X-ray spectroscopy instrumentation is a viable route for attaining well-resolved VTC-XES features for inorganic compounds of 3d transition metals, even for samples of limited quantity or suffering from sensitivity to the atmosphere. The experimental results are in good agreement with results produced by real-space Green's function and time-dependent density functional theory (TDDFT) methods, respectively. Hence, we propose that VTC-XES, when equipped with appropriate theoretical support, can be a valuable complement to X-ray absorption pre-edge features for more detailed characterization of a compound's electronic structure. We expect similar analyses will find application in a broad range of materials chemistry research and provide both fundamental and applied insights.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Sulfur Chemical and Electronic Structure with Experimental Observation and Quantitative Theoretical Prediction of Kα and Valence-to-Core Kβ X-ray Emission Spectroscopy

An extensive experimental and theoretical study of the Kα and Kβ high-resolution X-ray emission spectroscopy (XES) of sulfur-bearing systems is presented here. This study encompasses a wide range of organic and inorganic compounds, including numerous experimental spectra from both prior published work and new measurements. Employing a linear-response time-dependent density functional theory (LR-TDDFT) approach, strong quantitative agreement is found in the calculation of energy shifts of the core-to-core Kα as well as the full range of spectral features in the valence-to-core Kβ spectrum. The ability to accurately calculate the sulfur Kα energy shift supports the use of sulfur Kα XES as a bulk-sensitive tool for assessing sulfur speciation. The fine structure of the sulfur Kβ spectrum, in conjunction with the theoretical results, is shown to be sensitive to the local electronic structure including effects of symmetry, ligand type and number, and, in the case of organosulfur compounds, to the nature of the bonded organic moiety. This agreement between theory and experiment, augmented by the potential for high-access XES measurements with the latest generation of laboratory-based spectrometers, demonstrates the possibility of broad analytical use of XES for sulfur and nearby third-row elements. The effective solution of the forward problem, i.e., successful prediction of detailed spectra from known molecular structure, also suggests future use of supervised machine learning approaches to experimental inference, as has seen recent interest for interpretation of X-ray absorption near-edge structure (XANES).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory-Based X-ray Absorption Spectroscopy on a Working Pouch Cell Battery at Industrially-Relevant Charging Rates

Li-ion battery (LIB) research has continuing importance for the entire range of applications from consumer products to vehicle electrification and grid stabilization. In many cases, standard electrochemical methods only provide an overall voltage or specific capacity, giving an inadequate description of parallel redox processes or chemical gradients at the particle and pack level. X-ray absorption fine structure (XAFS) is frequently used to augment bulk electrochemical data, as it provides element-specific changes in oxidation state and local atomic structure. Such microscopic descriptors are crucial for elucidating charge transfer and structural changes associated with bonding or site mixing, two key factors in evaluating state of charge and modes of cell failure. However, the impact of XAFS on LIB research has been significantly constrained by a logistical barrier: contemporary XAFS work is performed almost exclusively at synchrotron X-ray light sources, where beamtime is infrequent and experiment time-frames are limited. In this report we show that modern laboratory-based XAFS cannot only be applied to, e.g., characterization of ex situ LIB electrode materials, but can also be used for operando studies at industrially-relevant charging rates in a standard pouch cell preparation. Such capability enables accelerated discovery of new materials and improved operation modes for LIBs.

25 ENERGY STORAGE↗

An improved laboratory-based x-ray absorption fine structure and x-ray emission spectrometer for analytical applications in materials chemistry research

X-ray absorption fine structure (XAFS) and x-ray emission spectroscopy (XES) are advanced x-ray spectroscopies that impact a wide range of disciplines. Furthermore, unlike the majority of other spectroscopic methods, XAFS and XES are accompanied by an unusual access model, wherein the dominant use of the technique is for premier research studies at world-class facilities, i.e., synchrotron x-ray light sources. In this paper, we report the design and performance of an improved XAFS and XES spectrometer based on the general conceptual design of Seidler et al. [Rev. Sci. Instrum. 85, 113906 (2014)]. New developments include reduced mechanical degrees of freedom, much-increased flux, and a wider Bragg angle range to enable extended x-ray absorption fine structure (EXAFS) measurement and analysis for the first time with this type of modern laboratory XAFS configuration. This instrument enables a new class of routine applications that are incompatible with the mission and access model of the synchrotron light sources. To illustrate this, we provide numerous examples of x-ray absorption near edge structure (XANES), EXAFS, and XES results for a variety of problems and energy ranges. Highlights include XAFS and XES measurements of battery electrode materials, EXAFS of Ni with full modeling of results to validate monochromator performance, valence-to-core XES for 3d transition metal compounds, and uranium XANES and XES for different oxidation states. Taken en masse , these results further support the growing perspective that modern laboratory-based XAFS and XES have the potential to develop a new branch of analytical chemistry.

47 OTHER INSTRUMENTATION↗

Double-ionization satellites in the x-ray emission spectrum of Ni metal

We report measurements of the nonresonant x-ray emission spectroscopy (XES) from Ni metal in an energy range spanning the Kβ diagram line, valence-to-core emission, and double-ionization (DI) satellites that appear beyond the single-particle Fermi level. We make special use of a laboratory-based x-ray spectrometer capable of both x-ray emission and x-ray absorption measurements to accurately align the XES and x-ray absorption spectra to a common energy scale. The careful alignment of energy scales is requisite for correction of the strong sample absorption of DI fluorescence above the Ni K-edge energy. The successful correction of absorption effects allows a determination of the branching ratios for the [1s3d], [1s3p] , [1s2p] and [1s2s] satellites with respect to their corresponding diagram lines. We compare our results with other work, finding good agreement with prior experiments and with theoretical calculations in the multiconfiguration Dirac-Fock framework.

74 ATOMIC AND MOLECULAR PHYSICS↗