Search NASA⌕ Search

Engineering topics

Jain, Jinesh

Publications and source records attributed to Jain, Jinesh.

At least 19 records

LIBS Applications to Liquids and Solids in Liquids

In this chapter, LIBS instrumentation and data collection system used for the analysis of liquids and solids in liquids are discussed. LIBS measurements of bulk liquid samples and solids submerged in aqueous media, measurements made by focusing laser pulses on liquid surfaces, and measurements of liquids after various sample treatments are presented. In addition, the working mechanism of NETL‐developed field‐deployable LIBS sensor and its preliminary performance in field measurements are also reported.

atomic emission spectroscopy↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Applied Spectra, Inc.

Groundwater resources can be contaminated by a variety of surface and subsurface sources. For instance, metals can be leached from surface dumps (e.g. landfills, etc.) and reach groundwater supplies by percolation though the soil. Additionally, subsurface activities such as geologic carbon storage (GCS) could result in contamination. In the event of CO2 leakage, freshwater above the injection site can potentially be contaminated with metals either originating from the formation fluids or leached from formation rocks by CO2 acidification. Detection of these contaminating metals is critical for maintaining water safety and providing an early warning of a containment breach. Therefore, a compact, subsurface capable laser induced breakdown spectroscopy (LIBS) based sensor has been developed for groundwater quality monitoring applications. LIBS sensor technology has been advanced from benchtop feasibility studies to a custom fabricated, watertight prototype. The all optical sensor head is built using a low cost passively Q-switched (PQSW) laser, which is fiber coupled to a control unit containing the pump laser and a gated spectrometer. Separating the LIBS excitation laser from the pump and spectrometer allows the expensive and fragile components to remain in a safe, central location while only the sensor head needs to enter the subsurface. Testing of the prototype sensors show Limits of Detection (LODs) comparable to benchtop, actively Q-switched systems and has verified that the fiber coupling and triggering schemes perform as desired.

McIntyre, Dustin↗

Elemental mapping and geochemical characterization of gas producing shales by laser induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) has been used for the analysis of hydrocarbon bearing shale samples. Shale samples taken from a Marcellus gas well at depths ranging from 7498 to 7551 ft (2285.4–2301.5 m) were analyzed by LIBS using an 81 × 81 grid pattern covering an 8 × 8 mm area. The data collected from these experiments were used to construct 2D elemental maps for each sample including the hydrocarbon forming elements C and H. Results show that the spatial elemental composition of the shale varies due to the matrix of the rock, and as a function of the sample depth. The accuracy of the analysis was confirmed by analyzing a shale sample of known elemental concentrations and obtaining a good agreement between analyzed and reference values. It has been shown that LIBS can be used to determine elemental composition variations in hydrocarbon bearing shales in a laboratory setting. In conclusion, extending this capability into wellbores will enable producers to rapidly target resources with greater accuracy.

04 OIL SHALES AND TAR SANDS↗

Quantification of dissolved metals in high-pressure CO 2 -water solutions by underwater laser-induced breakdown spectroscopy

Underwater laser-induced breakdown spectroscopy has been employed for the measurement of dissolved metals (Mg, Ca, Sr, Ba and Mn) in high-pressure CO 2 -water solutions. The CO 2 pressure was varied over the range from 10 to 400 bars and the concentrations of Mg, Ca, Sr, Ba and Mn were determined by spectral analysis and establishing the calibration curves. Limit of detection (LOD) for Mg, Ca, Sr, Ba, and Mn at 10 bars were found to be 31.7 ppm, 2.5 ppm, 3.3 ppm, 4.4 ppm, and 10.5 ppm, respectively. The LOD for Mg, Ca, Sr, and Ba were unaffected by the pressure however, a 2-fold decrease in LOD of Mn was observed with an increasing pressure from 10 to 400 bars. The results demonstrate that low-ppm range concentrations of Mg, Ca, Sr, Ba and Mn can be precisely measured in CO 2 -charged water at varied pressure conditions by using underwater LIBS. The study has implications in monitoring of CO 2 leak in carbon sequestration.

36 MATERIALS SCIENCE↗

A Study of Eu and Yb in aqueous solution by underwater laser-induced breakdown spectroscope

We present the use of under water laser induced breakdown spectroscopy (LIBS) to detect two rare earth elements; Eu and Yb dissolved in bulk aqueous solutions at ambient and high-pressure conditions. Strong emission lines of Eu and Yb were identified in the underwater LIBS spectra. Temporal evolution of plasma, the effect of laser pulse energy, and the effect of pressure on the spectral emission were studied. Calibration curves were developed to demonstrate the possibility of using LIBS technique for their quantification and limits of detection were estimated.

Bhatt, Chet R.↗

Evaluation of a commercially available passively Q-switched Nd:YAG laser with LiF:F-2(-) saturable absorber for laser-induced breakdown spectroscopy

Interest in passively Q-switched microchip lasers as a means for miniaturization of laser-induced breakdown spectroscopy (LIBS) apparatus has rapidly grown in the last years. To explore the possibility of using a comparatively UV-Vis transparent absorber, we herein present the first report on the evaluation of a commercially available flash lamp-pumped passively Q-switched Nd:YAG laser with LiF:F 2 - saturable absorber as an excitation source in LIBS. Quantitative measurements of barium, strontium, rubidium and lithium in granite, rhyolite, basalt and syenite whole-rock glass samples were performed. Ablation craters produced on a rock glass sample were characterized using a computerized X-ray tomography. Using a gated intensified benchtop spectrometer, limits of detection of 0.97, 23, 37, and 144 ppm were obtained for Li, Sr, Rb, and Ba, respectively. Finally, we discuss the advantages of using such a laser unit for LIBS applications in terms of ablation efficiency, analytical performances, output energy, and standoff capabilities.

36 MATERIALS SCIENCE↗

Determination of elemental composition of shale rocks by laser induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) is used for elemental characterization of outcrop samples from the Marcellus Shale. Powdered samples were pressed to form pellets and used for LIBS analysis. Partial least squares regression (PLS-R) and univariate calibration curves were used for quantification of analytes. The matrix effect is substantially reduced using the partial least squares calibration method. Predicted results with LIBS are compared to ICP-OES results for Si, Al, Ti, Mg, and Ca. As for C, its results are compared to those obtained by a carbon analyzer. Relative errors of the LIBS measurements are in the range of 1.7 to 12.6%. The limits of detection (LODs) obtained for Si, Al, Ti, Mg and Ca are 60.9, 33.0, 15.6, 4.2 and 0.03 ppm, respectively. An LOD of 0.4 wt.% was obtained for carbon. Finally, this study shows that the LIBS method can provide a rapid analysis of shale samples and can potentially benefit depleted gas shale carbon storage research.

58 GEOSCIENCES↗