Search NASA⌕ Search

Engineering topics

Jakubowski, Marcin

Publications and source records attributed to Jakubowski, Marcin.

Long plasma duration operation analyses with an international multi-machine (tokamaks and stellarators) database

Combined high-fusion performance and long-pulse operation is one of the key integration challenges for fusion energy development in magnetic devices. Addressing these challenges requires an integrated vision of physics and engineering aspects with the purpose of simultaneously increasing time duration and fusion performance. Significant progress has been made in tokamaks and stellarators, including very recent achievement in duration and/or performance. This progress is reviewed by analyzing the experimental data (109 plasma pulses with a total of 3200 data points, i.e. on average 29 data per pulse) provided by ten tokamaks (in alphabetical order: Axially Symmetric Divertor Experiment Upgrade, DIII-D, Experimental Advanced Superconducting Tokamak, Joint European Torus, JT-60 Upgrade, Korea Superconducting Tokamak Advanced Research, tokamak à configuration variable, Tokamak Fusion Test Reactor, Tore Supra, W Environment in Steady-State Tokamak) and two stellarators (Large Helical Device and Wendelstein 7-X) expanding the pioneering work of Kikuchi (Kikuchi M. and Azumi M. 2015 Frontiers in Fusion Research II: Introduction to Modern Tokamak Physics (Springer)). Data have been gathered up to January 2022 and coordination has been provided by the recently created International Energy Agency-International Atomic Energy Agency international Coordination on International Challenges on Long duration OPeration group. By exploiting the multi-machine international database, recent progress in terms of injected energies (e.g. 1730 MJ in L-mode, 425 MJ in H-mode), durations (1056 s in L-mode, 101 s in H-mode), injected powers, and sustained performance will be reviewed. Progress has been made to sustain long-pulse operation in tokamaks and stellarators with superconducting coils, actively cooled components, and/or with metallic walls. The graph of the fusion triple products as a function of duration shows a dramatic reduction of, at least two orders of magnitude when increasing the plasma duration from less than 1 s to 100 s. Indeed, long-pulse operation is usually reached in dominant electron-heating modes at reduced density (current drive optimization) but with low ion temperatures ranging from 1 to 3 keV for discharges above 100 s. Difficulties in extending the duration may arise from coupling high heating powers over long durations and the evolving plasma-wall interaction towards an unstable operational domain. Possible causes limiting the duration and critical issues to be addressed prior to ITER operation and DEMO design are reported and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of plasma beta effects on the island divertor transport in the standard configuration of W7-X

The influence of plasma beta effects on the edge plasma transport in the Wendelstein 7-X standard configuration is studied systematically by using EMC3-EIRENE combined with a 3D equilibrium code named HINT. The magnetic topology changes induced by plasma beta effects are significantly reflected in plasma transport behaviors and heat flux patterns on divertor targets. After validating the modeling strategy by comparisons with experimental data, the extended simulations for high performance plasmas show that the threshold separatrix density for accessing the power detachment is reduced in higher beta plasmas. Compared with the vacuum field case, the impurity radiation distributions with finite beta effects are modified in the magnetic island region. The divertor heat flux is distributed more evenly along the toroidal direction on the strike line at the vertical target. The strike line on the horizontal target moves towards the pumping gap with an increase in the plasma beta. In addition, the different pressure profiles with the same central beta also result in a modified heat flux pattern on the divertor targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion temperature clamping in Wendelstein 7-X electron cyclotron heated plasmas

The neoclassical transport optimization of the Wendelstein 7-X stellarator has not resulted in the predicted high energy confinement of gas fueled electron-cyclotron-resonance-heated (ECRH) plasmas as modelled in (Turkin et al 2011 Phys. Plasmas 18 022505) due to high levels of turbulent heat transport observed in the experiments. The electron-turbulent-heat transport appears non-stiff and is of the electron temperature gradient (ETG)/ion temperature gradient (ITG) type (Weir et al 2021 Nucl. Fusion 61 056001). As a result, the electron temperature T e can be varied freely from 1 keV–10 keV within the range of P ECRH = 1–7 MW, with electron density n e values from 0.1–1.5 × 10 20 m –3 . By contrast, in combination with the broad electron-to-ion energy-exchange heating profile in ECRH plasmas, ion-turbulent-heat transport leads to clamping of the central ion temperature at T i ~ 1.5 keV ± 0.2 keV. In a dedicated ECRH power scan at a constant density of $\langle n_{e} \rangle$ = 7 × 10 19 m –3 , an apparent 'negative ion temperature profile stiffness' was found in the central plasma for (r/a < 0.5), in which the normalized gradient ∇T i /T i decreases with increasing ion heat flux. The experiment was conducted in helium, which has a higher radiative density limit compared to hydrogen, allowing a broader power scan. This 'negative stiffness' is due to a strong exacerbation of turbulent transport with an increasing ratio of T e /T i in this electron-heated plasma. This finding is consistent with electrostatic microinstabilities, such as ITG-driven turbulence. Theoretical calculations made by both linear and nonlinear gyro-kinetic simulations performed by the GENE code in the W7-X three-dimensional geometry show a strong enhancement of turbulence with an increasing ratio of T e /T i . The exacerbation of turbulence with increasing T e /T i is also found in tokamaks and inherently enhances ion heat transport in electron-heated plasmas. This finding strongly affects the prospects of future high-performance gas-fueled ECRH scenarios in W7-X and imposes a requirement for turbulence-suppression techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EMC3-EIRENE simulation of first wall recycling fluxes in W7-X with relation to H-alpha measurements

In the Wendelstein 7-X stellarator, the main locations of particle sources are expected to be the carbon divertors, baffles and graphite heat shield first wall. In this paper, the heat shield is implemented in EMC3-EIRENE to understand the expected areas and magnitudes of the recycling flux to this component. It is found that in the simulation the heat shield is not a significant source of recycling neutrals. The areas of simulated recycling flux are shown to correlate well with footprints of plasma-wetting seen in post-experimental campaign in-vessel inspection photos. EMC3-EIRENE reconstruction of line-integrated H-alpha measurements at the heat shield indicate that the majority of emission does not come from local recycling neutrals. Rather, the H-alpha signals at the heat shield are dominated by ionization of neutrals which have leaked from the divertor/baffle region into the midplane. The magnitude of the H-alpha line emission from the synthetic reconstruction is consistent with the experiment, indicating that a large overestimation of heat shield recycling would occur if these measurements were assumed to be from local recycling sources. In the future, it may be possible to obtain some information of local recycling from the heat shield since it was found that the majority of the recycling flux occurs on two well-localized areas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of plasma parameters in the divertor island of Wendelstein 7-X through line-ratio spectroscopy on helium

We report electron temperature T e and density n e have been measured in the divertor island of Wendelstein 7-X by means of a new thermal He-beam system utilizing line-ratio spectroscopy. This system is equipped with a poloidal arrangement of five gas valves that allows to infer 2D plasma profiles T e ( R,Z ) and n e ( R,Z ) across the magnetic island forming the island divertor. A local maximum in T e ( R,Z ) was measured along the flux surfaces located between the island center and the outer separatrix. In the island center, characterized by closed field lines, a clear local minimum in T e was measured, indicating that no direct heat deposition occurs in this region and that the perpendicular heat flux from the core plasma into this domain is small. Increasing the island size leads to a reduction of the connection length in the scrape-off layer (SOL) and to a shift of the island center towards the divertor target. In this scenario, the T e ( R,Z ) are reduced in the entire island domain. Density profiles are found flat across the divertor island for both island size scenarios. These findings are supported by similar observations made with a reciprocating probe plunging through the same SOL island at the mid-plane of W7-X representing the upstream position in this 3D divertor geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stable heat and particle flux detachment with efficient particle exhaust in the island divertor of Wendelstein 7-X

The island divertor concept is an innovative and promising idea to handle heat and particle exhaust in stellarators. At the Wendelstein 7-X (W7-X) stellarator, this divertor concept plays a central role in the device mission to demonstrate reactor relevant plasma confinement for steady-state time scales of up to 30 minutes in the high-performance campaign (OP2) starting in 2022. During the recently concluded first campaign with the inertially cooled island divertor, a large step in the experimental qualification of this divertor concept has been made. In discharges heated with electron cylotron resonance heating of 5-6 MW, central densities in the range of 0.7-1.2 × 10 20 m -3 have been reached in combination with full divertor heat flux detachment. Also, significant neutral gas pressures and neutral compression ratios were shown for the first time in combination with reduced divertor particle flux. The divertor heat loads drop by an order of magnitude from >5 MW m -2 to below 0.5 MW m-2 with increasing density, and substantial compression of neutrals reaching neutral pressure in the sub-divertor volume of >6.0 × 10 -4 mbar was seen. These elevated neutral pressure levels can be obtained and maintained with an up to 80% reduction of the particle fluxes onto the divertor target tiles. This discharge scenario was held stably detached for up to 28 seconds, which is equivalent to several hundred energy confinement times τ E and longer than the time scales for current relaxation. No impurity accumulation was seen at constant Z eff ≈ 1.5 and the stored energy stayed constant at levels of W dia >600 kJ. The level of neutral pressure and compression reached in this scenario extrapolates well to the steady-state particle exhaust requirements for high-performance steady-state operation in OP2, in which the fully actively cooled high-heat-flux divertor will be available. Finally, an overview of this recently discovered divertor regime is given and the status of the physics understanding based on modeling of these regimes with the EMC3-EIRENE code is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of toroidal plasma currents on the Wendelstein 7-X Scrape-Off Layer

The role of toroidal plasma currents for the island divertor scrape-off layer in the stellarator Wendelstein 7-X is investigated using reciprocating electric probes. Experiments show that small amounts (of a few kA) of plasma current are sufficient to significantly affect the scrape-off layer plasma conditions, whereas higher plasma currents above 10kA result in more drastic changes. This behavior is linked to the effect of the plasma current on the rotational transform profile, which can result in significant shifts of the edge magnetic islands. These shifts affect the interaction of the islands with the divertor and can eventually result in a transition from a diverted to a limited plasma configuration. The probe observations are complemented by further edge diagnostics including plasma flow measurements, divertor Langmuir probes, divertor thermography and impurity spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning of the rotational transform in Wendelstein 7-X

The control of rotational transform in Wendelstein 7-X (W7-X) is key to the island divertor operation and safety of plasma facing components. The island divertor concept in W7-X relies on an edge flux surface with rotational transform of $t$ = 1 resonating with an intrinsic n/m = 5/5 resonance to form a five lobed island chain. This island chain intersects with divertor plates to give rise to the island divertor. Changes in the relative position of the rational surface and the divertor plates can result in changes in divertor performance, thus the control of the rotational transform is essential to operation of the W7-X device. During the first divertor campaign electromagnetic loads resulted in elastic deformations of the shaped modular stellarator coils. Such deformations made these coils more planar, reducing the vacuum rotational transform, subsequently shifting the $t$ = 1 resonance outward. Unintended plasma wall interactions provided the first clear evidence of this effect during plasma operation. Flux surface measurements were utilized to estimate the correct level of current in the planar coils for correction of $t$, and found to be around ~-100 A . Scans of the planar coil current for iota correction were performed during plasma operation. These measurements suggest planar coil currents between -250 and ~ 0 A would place the strike lines at the designed distance from the pumping gaps. Divertor Langmuir and upstream probe measurements confirm these estimates along with measurements of divertor neutral gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results from divertor operation in Wendelstein 7-X

Wendelstein 7-X is a highly optimized stellarator that went into operation in 2015. With a 30 cubic meter volume, a superconducting coil system operating at 2.5 T, and steady-state heating capability of eventually up to 10 MW, it was built to demonstrate the benefits of optimized stellarators at parameters approaching those of a fusion power plant. We report here on the first results with the test divertor installed, during the second operation phase, which was performed in the second half of 2017. Operation with a divertor, and the addition of several new fueling systems, allowed higher density operation in hydrogen as well as helium. Here, the effects that higher density operation had on both divertor operation and global confinement will be described. In particular, at high densities detachment was observed, and the highest fusion triple product for a stellarator was achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error fields in the Wendelstein 7-X stellarator

The role of error fields in stellarators is explored in this work through simulations of, and experiments performed on, the Wendelstein 7-X (W7-X) stellarator. Previous experimental results, based on limiter plasmas in W7-X, suggest that error fields are small in the experiment based on limiter plasmas. In this work, we document results from the first divertor campaign on W7-X with a focus on error fields resonant with the edge island divertor structure. Measurements obtained using divertor thermocouples corroborate earlier limiter results that the error fields are small and correctable, requiring only 5% of the total rated current of the trim coil system. The effect of these error fields on magnetic geometry and topology are investigated using the flux surface measurement technique. The resulting divertor thermal load asymmetry is modeled via field line diffusion and compared to experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared imaging systems for wall protection in the W7-X stellarator (invited)

Here, Wendelstein 7-X aims at quasi-steady state operation with up to 10 MW of heating power for 30 min. Power exhaust will be handled predominantly via 10 actively water cooled CFC (carbon-fiber-reinforced carbon) based divertor units designed to withstand power loads of 10 MW/m 2 locally in steady state. If local loads exceed this value, a risk of local delamination of the CFC and failure of entire divertor modules arises. Infrared endoscopes to monitor all main plasma facing components are being prepared, and near real time software tools are under development to identify areas of excessive temperature rise, to distinguish them from non-critical events, and to trigger alarms. Tests with different cameras were made in the recent campaign. Long pulse operation enforces additional diagnostic design constraints: for example, the optics need to be thermally decoupled from the endoscope housing. In the upcoming experimental campaign, a graphite scraper element, in front of the island divertor throat, will be tested as a possible means to protect the divertor pumping gap edges during the transient discharge evolution.

47 OTHER INSTRUMENTATION↗

Study of impurity behaviour for first magnetic configuration changes in W7-X plasmas by means of PHA spectra

Transport properties of impurities in stellarators are sensitive to potential variations on flux-surfaces, and thermodynamic forces from the bulk plasma which might be affected by changes in magnetic field properties. In this contribution, the effect of planar coil current changes on the core impurity behavior in the first operating phase of Wendelstein 7-X (W7-X) is described. Hydrogen plasmas, at different heating power levels were investigated showing Core-Electron-Root-Confinement (CERC) conditions, characterized by peaked Te profiles and positive radial electric fields in the plasma core. Additionally, impurity spectra in the x-ray emission range between 1 and 10 keV were measured by the Pulse Height Analysis (PHA) diagnostic. The line-integrated measurements of transitions in sulphur, chlorine and argon are in the focus of this analysis. First observations indicate that the scans of the magnetic configuration did not affect strongly the impurity concentration in the core. Clear differences in the impurity content, however, have been observed when the ECRH power was changed, which affects the bulk plasma properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error field measurement, correction and heat flux balancing on Wendelstein 7-X

The measurement and correction of error fields in Wendelstein 7-X (W7-X) is critical to long pulse high beta operation, as small error fields may cause overloading of divertor plates in some configurations. Accordingly, as part of a broad collaborative effort, the detection and correction of error fields on the W7-X experiment has been performed using the trim coil system in conjunction with the flux surface mapping diagnostic and high resolution infrared camera. In the early commissioning phase of the experiment, the trim coils were used to open an n/m = 1/2 island chain in a specially designed magnetic configuration. The flux surfacing mapping diagnostic was then able to directly image the magnetic topology of the experiment, allowing the inference of a small similar to 4 cm intrinsic island chain. The suspected main sources of the error field, slight misalignment and deformations of the superconducting coils, are then confirmed through experimental modeling using the detailed measurements of the coil positions. Observations of the limiters temperatures in module 5 shows a clear dependence of the limiter heat flux pattern as the perturbing fields are rotated. Plasma experiments without applied correcting fields show a significant asymmetry in neutral pressure (centered in module 4) and light emission (visible, H-alpha, CII, and CIII). Such pressure asymmetry is associated with plasma-wall (limiter) interaction asymmetries between the modules. Application of trim coil fields with n = 1 waveform correct the imbalance. Confirmation of the error fields allows the assessment of magnetic fields which resonate with the n/m = 5/5 island chain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗