An airborne lidar instrument for detection of OH using the technique of laser-induced fluorescence

Under suitable laboratory conditions, it has been demonstrated that the laser-induced fluorescence (LIF) measurement technique is sensitive enough to detect single atoms and molecules. This potential sensitivity has provided motivation for the development of this technique for ambient OH measurements. The present paper is concerned with an airborne lidar instrument for measuring OH concentration as used for the NASA GTE/CITE (Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation) intercomparison experiments during the fall of 1983 and the spring of 1984. A description is given of a working airborne instrument for measurements of OH in ambient air. The detection sensitivity demonstrated in the experiments should be sufficient for routine measurements in areas in which the OH concentration is in the range of high 1,000,000 molecule per cu cm or higher.

Davis, L. I., Jr.↗

Shot noise limited detection of OH using the technique of laser-induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Shot noise limited detection of OH using the technique of laser induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Line broadening in multiphoton processes with a resonant intermediate transition

It is found that the line width of the excitation spectrum for multiphoton ionization is broadened much more severely than the cascade fluorescence originating from the resonant intermediate level. These results derive from the mutual effects of the ionizing and resonating transitions, which are not properly accounted for in perturbative treatments. In general, the ionization line shape can be expressed as the sum of two Lorentzian components, each with different degrees of broadening. This line shape reduces to that of the resonating transition in the limit of vanishing intensities. Moreover, the fluorescence line shape may also exhibit a second component whose amplitude may become important under certain conditions.

Wang, C. C.↗

Absorption technique for OH measurements and calibration

An absorption technique is described which utilizes a stabilized frequency-doubled tunable dye laser and a long-path White cell with high mirror reflectivities both in the red and UV. In laboratory conditions it has been possible to routinely obtain a detection sensitivity of 3 parts in 1,000,000 over absorption paths less than 1 m in length and a detection sensitivity of approximately 6 parts in 100,000 over an absorption path of the order of 1 km. The latter number corresponds to 3,000,000 OH molecules/cu cm, and therefore the technique should be particularly useful for calibration the fluorescence instrument for OH measurements. However, the presence of atmospheric fluctuations coupled with intensity variation accompanying frequency scanning appears to degrade the detection sensitivity in outdoor ambient conditions, thus making it unlikely that this technique can be employed for direct OH monitoring.

Bakalyar, D. M.↗