Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

X-ray-line coincidence photopumping in a potassium-chlorine mixed plasma

Exploiting the multiple long pulse capability and suite of x-ray diagnostics of the Orion laser, we have set out to explore line coincidence photopuming—the enhancement in population of an atomic level brought on by resonant absorption of x rays from a different emitting ion. Unlike previous work, the two ions are in the same plasma and so the experiment is an x-ray analog of the well-known Bowen resonance fluorescence mechanism that operates in astrophysical situations in the optical region. Herein, our measurements have shown enhanced fluorescence in a chlorine plasma, attributable to line coincident photopumping from co-mixed potassium ions. To detect this relatively low signal-to-noise phenomenon, the data from multiple shots are combined, and the statistical method of bootstrapping is used to assign a confidence value to the measured enhancement, resulting in an estimate of the enhancement of 39 ± 18 16 % compared to the null case, where no pumping occurs. The experimental results have been compared to coupled radiation-transport and radiation hydrodynamics simulations using the CRETIN code together with the NYM radiation hydrodynamics model and agreement has been found, with the simulations also predicting modest enhancement.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-resolution measurements of Cl 15 + line shifts in hot, solid-density plasmas

The shifts of the 1s3p 1 P 1 → 1s 2 1 S 0 He-β transition of Cl 15+ were measured in hot (≥ 600 eV), dense (1–2 g/cm 3 ) plasmas generated by a (66–151)-J short-pulse laser beam at the Orion laser facility. The subpicosecond laser beam irradiated optically thin, KCl microdot targets buried in layers of plastic. The measured red shifts ranged from 4.8 ± 1.1 eV for unshocked to 5.9 ± 1.2 eV for shocked targets. Furthermore, these values are significantly smaller than recent predictions from a self-consistent-field ion-sphere model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas

The Orion high-resolution x-ray (OHREX) spectrometer has been a successful tool for measuring the shapes of density-broadened spectral lines produced in short-pulse heated plasmas at the Orion laser facility. We have recently outfitted the instrument with a charge-couple device (CCD) camera, which greatly increased the accuracy with which we can perform line-shift measurements. Because OHREX is located on the outside of the Orion target chamber, no provisions for the shielding of electromagnetic pulses are required. With the CCD, we obtained a higher signal-to-noise ratio than we previously obtained with an image-plate detector. As a result, this allowed us to observe structure in the image produced by the diffraction from the two OHREX crystals, which was highly reproducible from shot to shot. This structure will ultimately limit the accuracy of our spectroscopic measurements

47 OTHER INSTRUMENTATION↗

Modelling K shell spectra from short pulse heated buried microdot targets

K shell X-ray emission measurements have been used to diagnose plasma conditions in short-pulse heated buried microdot targets on the Orion high power laser. These experiments have been used to validate simulations of short pulse laser-solid interaction that combine hybrid PIC modelling of the laser absorption with radiation-hydrodynamics simulations including an electron transport model. Comparison of these simulations with streaked K shell spectroscopy show the importance of including radial gradients in fitting the spectra. An example is presented of the emission of sulphur from a 50 µm diameter microdot sample buried in a plastic foil. Previously agreement between simulation and experiment was obtained only by treating the absorbed energy, electron temperature and beam divergence as fitting parameters. Overall, the good agreement obtained in this work used the measured laser energy and laser pulse length and calculated the laser-solid target interaction from first principles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lineshape measurements of He- β spectra on the ORION laser facility

Here, we have utilized a newly developed high-resolution X-ray spectrometer to measure the shapes of spectral lines produced from laser-irradiated targets on the Orion laser facility in the United Kingdom. We present measurements of the He-β spectra of chlorine and chromium from targets irradiated by either a long-pulse or a short-pulse laser beam. The experimental conditions provide a spread in plasma density ranging from about 10 19 to about 10 24 cm –3 . We present spectral calculations that show that the relative intensities of the Li-like satellite lines can be used to infer the density in the lower range, especially if the lithiumlike satellite lines are well resolved. In addition, we use the Stark-broadened width of the He-β line to infer densities above about 10 22 cm –3 . In the case of a short-pulse irradiated chromium foil, we find that the He-like chromium is produced at a density of almost 8 g/cm 3 , i.e., solid density. In addition, we can infer the electron temperature from the observation of dielectronic recombination satellite lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer

We have developed a high-resolution x-ray spectrometer for measuring the shapes of spectral lines produced from laser-irradiated targets on the Orion laser facility. The instrument utilizes a spherically bent crystal geometry to spatially focus and spectrally analyze photons from foil or microdot targets. The high photon collection efficiency resulting from its imaging properties allows the instrument to be mounted outside the Orion chamber, where it is far less sensitive to particles, hard x-rays, or electromagnetic pulses than instruments housed close to the target chamber center in ten-inch manipulators. Moreover, Bragg angles above 50° are possible, which provide greatly improved spectral resolution compared to radially viewing, near grazing-incidence crystal spectrometers. These properties make the new instrument an ideal lineshape diagnostic for determining plasma temperature and density. We describe its calibration on the Livermore electron beam ion trap facility and present spectral data of the K-shell emission from highly charged sulfur produced by long-pulse as well as short-pulse beams on the Orion laser in the United Kingdom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress towards a laser produced relativistic electron-positron pair plasma

Here, a set of experiments has been performed exploring unique characteristics of pair jets and plasmas at several energetic short-pulse laser facilities including Titan at Livermore and OMEGA EP in Rochester, as well as the Osaka LFEX and AWE Orion lasers. New results are summarized, including positron beam emittance, scaling of pair production vs. laser energy, and initial results on the pair jet collimation using electromagnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot electron production in laser solid interactions with a controlled pre-pulse

Hot electron generation plays an important role in the fast ignition approach to inertial confinement fusion (ICF) and other applications with ultra-intense lasers. Hot electrons of temperature up to 10–20 MeV have been produced by high contrast picosecond duration laser pulses focussed to intensities of ∼10{sup 20} W cm{sup −2} with a deliberate pre-pulse on solid targets using the Vulcan Petawatt Laser facility. We present measurements of the number and temperature of hot electrons obtained using an electron spectrometer. The results are correlated to the density scale length of the plasma produced by a controlled pre-pulse measured using an optical probe diagnostic. 1D simulations predict electron temperature variations with plasma density scale length in agreement with the experiment at shorter plasma scale lengths (<7.5μm), but with the experimental temperatures (13–17 MeV) dropping below the simulation values (20–25 MeV) at longer scale lengths. The experimental results show that longer interaction plasmas produced by pre-pulses enable significantly greater number of hot electrons to be produced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ORION laser target diagnostics

The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗