Search NASA⌕ Search

Engineering topics

Jandel, M.

Publications and source records attributed to Jandel, M..

34 records · Page 2

Enhancing the detector for advanced neutron capture experiments

The Detector for Advanced Neutron Capture Experiments (DANCE) has been used for extensive studies of neutron capture, gamma decay, photon strength functions, and prompt and delayed fission-gamma emission. Despite these successes, the potential measurements have been limited by the data acquisition hardware. We report on a major upgrade of the DANCE data acquisition that simultaneously enables strait-forward coupling to auxiliary detectors, including high-resolution high-purity germanium detectors and neutron tagging array. The upgrade will enhance the time domain accessible for time-of-flight neutron measurements as well as improve the resolution in the DANCE barium fluoride crystals for photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LANL/LLNL Prompt Fission Neutron Spectrum Program at LANSCE and Approach to Uncertainties

New data on the prompt fission neutron spectra (PFNS) from neutron-induced fission with higher accuracies are needed to resolve discrepancies in the literature and to address gaps in the experimental data. The Chi-Nu project, conducted jointly by LANL and LLNL, aims to measure the shape of the PFNS for fission of {sup 239}Pu induced by neutrons from 0.5 to 20 MeV with accuracies of 3–5% in the outgoing energy from 0.1 to 9 MeV and 15% from 9 to 12 MeV and to provide detailed experimental uncertainties. Neutrons from the WNR/LANSCE neutron source are being used to induce fission in a Parallel-Plate Avalanche Counter (PPAC). Two arrays of neutron detectors are used to cover the energy range of neutrons emitted promptly in the fission process. Challenges for the present experiment include background reduction, use of {sup 239}Pu in a PPAC, and understanding neutron detector response. Achieving the target accuracies requires the understanding of many systematic uncertainties. The status and plans for the future will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt fission gamma-ray studies at DANCE

Measurements of correlated data on prompt-fission γ-rays (PFG) have been carried out for various actinide isotopes in recent years using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL). We have developed a model that conveniently parametrizes the correlated data of γ-ray multiplicity and energy. New results on two- dimensional prompt-fission γ-ray multiplicity versus energy distributions from spontaneous fission on ²⁵²Cf and neutron-induced fission on 242m Am are presented together with previously obtained results on 233,235 U and ²³⁹Pu. Correlated PFG data from ²⁵²Cf are also compared to results of the detailed theoretical model developed at LANL, for different thresholds of PFG energies. Future plans to measure correlated data on fission fragments, prompt fission neutrons and γ-rays at DANCE are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of position-sensitive time-of-flight spectrometer for fission fragment research

A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

2E-2v↗

235U Resolved Resonance Evaluation for Benchmark Calculations in the Intermediate Energy Region

The Working Party on International Nuclear Data Evaluation Co-operation (WPEC) subgroup 29 (SG 29) was established to investigate an issue with the 235U capture cross-section in the energy range 0.1 to 2.25 keV. The WPEC criticality calculation results indicated an overestimation of the 235U capture cross-section of 10% or more. To understand and solve the problem, a recommendation was made to perform new capture cross-section measurements followed by a resonance evaluation. Hence, time of-flight capture cross-section measurements were done at the Rensselaer Polytechnic Institute (RPI) and at the Los Alamos National Laboratory (LANL). These new measurements were used together with the computer code SAMMY to reevaluate the 235U resonance parameters in the energy range from thermal to 2.25 keV. The impact of the new evaluation in benchmark calculations was done for the critical benchmark sensitive to the 0.1 to 2.25 keV energy range. The purpose of this work is to describe the 235U SAMMY evaluation and present the critical benchmark results.

97 MATHEMATICS AND COMPUTING↗

Neutron capture measurement on {sup 173}Lu at LANSCE with DANCE detector

The (n,{gamma}) cross section on the unstable {sup 173}Lu(t{sub 1/2} = 1.37y) has been measured from thermal energy up to 200 eV at Los Alamos Neutron Science Center (LANSCE) with The Detector for Advanced Neutron Capture Experiements (DANCE). The main aim of this study is to validate and optimize reaction models for unstable nucleus. A preliminary capture yield will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(n,{gamma}) Experiments on tin isotopes

Neutron capture experiments on highly enriched {sup 117,119}Sn isotopes were performed with the DANCE detector array located at the Los Alamos Neutron Science Center. The DANCE detector provides detailed information about the multi-step {gamma}-ray cascade following neutron capture. Analysis of the experimental data provides important information to improve understanding of the neutron capture reaction, including a test of the statistical model, the assignment of spins and parities of neutron resonances, and information concerning the Photon Strength Function (PSF) and Level Density (LD) below the neutron separation energy. Preliminary results for the (n,{gamma}) reaction on {sup 117,119}Sn are presented. Resonance spins of the odd-A tin isotopes were almost completely unknown. Resonance spins and parities have been assigned via analysis of the multi-step {gamma}-ray spectra and directional correlations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A compact gas-filled avalanche counter for DANCE

A compact gas-filled avalanche counter for the detection of fission fragments was developed for a highly segmented 4π γ-ray calorimeter, namely the Detector for Advanced Neutron Capture Experiments located at the Lujan Center of the Los Alamos Neutron Science Center. It has been used successfully for experiments with 235 U, 238 Pu, 239 Pu, and 241 Pu isotopes to provide a unique signature to differentiate the fission from the competing neutron-capture reaction channel. We also used it to study the spontaneous fission in 252Cf. The design and performance of this avalanche counter for targets with extreme α-decay rate up to ~2.4×108/s are described.

252Cf↗

Measurement of the {sup 157}Gd(n,{gamma}) reaction with the DANCE {gamma} calorimeter array

The {sup 157}Gd(n,{gamma}) reaction was measured with the DANCE {gamma} calorimeter (consisting of 160 BaF{sub 2} scintillation detectors) at the Los Alamos Neutron Science Center. The multiplicity distributions of the {gamma} decay were used to determine the resonance spins up to E{sub n}=300 eV. The {gamma}-ray energy spectra for different multiplicities were measured for the s-wave resonances. The shapes of these spectra were compared with simulations based on the use of the DICEBOX statistical model code. Simulations showed that the scissors mode is required not only for the ground-state transitions but also for transitions between excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗