Use of Cumulative Degradation Factor Prediction and Life Test Result of the Thruster Gimbal Assembly Actuator for the Dawn Flight Project

The Dawn Ion Propulsion System is the ninth project in NASA s Discovery Program. The Dawn spacecraft is being developed to enable the scientific investigation of the two heaviest main-belt asteroids, Vesta and Ceres. Dawn is the first mission to orbit two extraterrestrial bodies, and the first to orbit a main-belt asteroid. The mission is enabled by the onboard Ion Propulsion System (IPS) to provide the post-launch delta-V. The three Ion Engines of the IPS are mounted on Thruster Gimbal Assembly (TGA), with only one engine operating at a time for this 10-year mission. The three TGAs weigh 14.6 kg.

Lo, C. John↗

Effect of Ceramic Ball and Hybrid Stainless Steel Bearing/Wheel Combinations on the Lifetime of a Precision Translation Stage for the SIM Flight Project

A study of hybrid material couples using the Spiral Orbit Tribometer (SOT) was initiated to investigate both lubricated (Pennzane X2000 and Brayco 815Z) and unlubricated Si3N4, 440C SS, Rex 20, Cronidur X30 and X40 plates with Cerbec SN-101-C (Si3N4) and 440C balls. The hybrid wheel/bearing assembly will be used on the Linear Optical Delay Line (LODL) stage as an element of the NASA Space Interferometry Mission (SIM). SIM is an orbiting interferometer linking a pair of telescopes within the spacecraft and, by using an interferometry technique and several precision optical stages, is able to measure the motions of known stars much better than current ground or space based systems. This measurement will provide the data to "infer" the existence of any plants, undetectable by other methods, orbiting these known stars.

Lo, C. John↗

Lubricated Bearing Lifetimes of a Multiply Alkylated Cyclopentane and a Linear Perfluoropolyether Fluid in Oscillatory Motion at Elevated Temperatures in Ultrahigh Vacuum

Bearing life tests in vacuum with three space liquid lubricants, two multiply alkylated cyclopentanes (MACs) and a linear perfluoropolyether (PFPE) were performed. Test conditions included: an 89 N axial load (mean Hertzian stress 0.66 GPa), vacuum level below 7x10(exp -4) Pa, and a +/-30deg dither angle. Dither rate was 75 cycles per minute. Higher (110 to 122 C) and lower temperature tests (75 C) were performed. For the higher temperature tests, the PFPE, Fomblin (Ausimont SpA) Z25 outperformed Pennzane (Shell Global Solutions) X-2000 by more than an order of magnitude. Lubricant evaporation played a key role in these high temperature results. At 75 C, the order was reversed with both Pennzane X-1000 and X-2000 outperforming Fomblin Z25 by more than an order of magnitude. Most Pennzane tests were suspended without failure. The primary failure mechanism in these lower temperature tests was lubricant consumption in the tribocontacts.

Braza, Joseph↗

Spiral Orbit Tribometer

The spiral orbit tribometer (SOT) bridges the gap between full-scale life testing and typically unrealistic accelerated life testing of ball-bearing lubricants in conjunction with bearing ball and race materials. The SOT operates under realistic conditions and quickly produces results, thereby providing information that can guide the selection of lubricant, ball, and race materials early in a design process. The SOT is based upon a simplified, retainerless thrust bearing comprising one ball between flat races (see figure). The SOT measures lubricant consumption and degradation rates and friction coefficients in boundary lubricated rolling and pivoting contacts. The ball is pressed between the lower and upper races with a controlled force and the lower plate is rotated. The combination of load and rotation causes the ball to move in a nearly circular orbit that is, more precisely, an opening spiral. The spiral s pitch is directly related to the friction coefficient. At the end of the orbit, the ball contacts the guide plate, restoring the orbit to its original radius. The orbit is repeatable throughout the entire test. A force transducer, mounted in-line with the guide plate, measures the force between the ball and the guide plate, which directly relates to the friction coefficient. The SOT, shown in the figure, can operate in under ultra-high vacuum (10(exp -9) Torr) or in a variety of gases at atmospheric pressure. The load force can be adjusted between 45 and 450 N. By varying the load force and ball diameter, mean Hertzian stresses between 0.5 and 5.0 GPa can be obtained. The ball s orbital speed range is between 1 and 100 rpm.

Pepper, Stephen V.↗

The Effect of 17-4 PH Stainless Steel on the Lifetime of a Pennzane(Trademark) Lubricated Microwave Limb Sounder Antenna Actuator Assembly Ball Screw for the AURA Spacecraft

During ground based life testing of a Microwave Limb Sounder (MLS) Antenna Actuator Assembly (AAA) ball-screw assembly, lubricant darkening and loss were noted when approximately 10 percent of required lifetime was completed. The MLS-AAA ball screw and nut are made from 17-4 PH steel, the nut has 440C stainless steel balls, and the assembly is lubricated with a Pennzane formulation containing a three weight percent lead naphthenate additive. Life tests were done in dry nitrogen at 50 C. To investigate the MLS-AAA life test anomaly, Spiral Orbit Tribometer (SOT) accelerated tests were performed. SOT results indicated greatly reduced relative lifetimes of Pennzane formulations in contact with 17-4 PH steel compared to 440C stainless steel. Also, dry nitrogen tests yielded longer relative lifetimes than comparable ultrahigh vacuum tests. Generally, oxidized Pennzane formulations yielded shorter lifetimes than non-oxidized lubricant. This study emphasizes surface chemistry effects on the lubricated lifetime of moving mechanical assemblies.

Jones, William R., Jr.↗

An Overview of Magnetic Bearing Technology for Gas Turbine Engines

The idea of the magnetic bearing and its use in exotic applications has been conceptualized for many years, over a century, in fact. Patented, passive systems using permanent magnets date back over 150 years. More recently, scientists of the 1930s began investigating active systems using electromagnets for high-speed ultracentrifuges. However, passive magnetic bearings are physically unstable and active systems only provide proper stiffness and damping through sophisticated controllers and algorithms. This is precisely why, until the last decade, magnetic bearings did not become a practical alternative to rolling element bearings. Today, magnetic bearing technology has become viable because of advances in micro-processing controllers that allow for confident and robust active control. Further advances in the following areas: rotor and stator materials and designs which maximize flux, minimize energy losses, and minimize stress limitations; wire materials and coatings for high temperature operation; high-speed micro processing for advanced controller designs and extremely robust capabilities; back-up bearing technology for providing a viable touchdown surface; and precision sensor technology; have put magnetic bearings on the forefront of advanced, lubrication free support systems. This paper will discuss a specific joint program for the advancement of gas turbine engines and how it implies the vitality of magnetic bearings, a brief comparison between magnetic bearings and other bearing technologies in both their advantages and limitations, and an examination of foreseeable solutions to historically perceived limitations to magnetic bearing.

Clark, Daniel J.↗

In Situ, On-Demand Lubrication System Developed for Space Mechanisms

Many moving mechanical assemblies (MMA) for space mechanisms rely on liquid lubricants to provide reliable, long-term performance. The proper performance of the MMA is critical in assuring a successful mission. Historically, mission lifetimes were short and MMA duty cycles were minimal. As mission lifetimes were extended, other components, such as batteries and computers, failed before lubricated systems. However, improvements in these ancillary systems over the last decade have left the tribological systems of the MMAs as the limiting factor in determining spacecraft reliability. Typically, MMAs are initially lubricated with a very small charge that is supposed to last the entire mission lifetime, often well in excess of 5 years. In many cases, the premature failure of a lubricated component can result in mission failure.

Marchetti, Mario↗

In-situ, On-demand Lubrication System for Space Mechanisms

Many of today's spacecraft have long mission lifetimes. Whatever the lubrication method selected, the initial lubricant charge is required to last the entire mission. Fluid lubricant losses are mainly due to evaporation, tribo-degradation, and oil creep out of the tribological regions. In the past, several techniques were developed to maintain the appropriate amount of oil in the system. They were based on oil reservoirs (cartridges, impregnated porous parts), barrier films, and labyrinth seals. Nevertheless, all these systems have had limited success or have not established a proven record for space missions. The system reported here provides to the ball-race contact fresh lubricant in-situ and on demand. The lubricant is stored in a porous cartridge attached to the inner or the outer ring of a ball bearing. The oil is released by heating the cartridge to eject oil, taking advantage of the greater thermal expansion of the oil compared to the porous network. The heating may be activated by torque increases that signal the depletion of oil in the contact. The low surface tension of the oil compared to the ball bearing material is utilized and the close proximity of the cartridge to the moving balls allows the lubricant to reach the ball-race contacts. This oil resupply system can be used to avoid a mechanism failure or reduce torque to an acceptable level and extend the life of the component.

Marchetti, Mario↗

Evaluation of an In-Situ, Liquid Lubrication System for Space Mechanisms Using a Vacuum Spiral Orbit Tribometer

Many moving mechanical assemblies (MMAs) for space applications rely on a small, initial charge of lubricant for the entire mission lifetime, often in excess of five years. In many cases, the premature failure of a lubricated component can result in mission failure. If lubricant could be resupplied to the contact in-situ, the life of the MMA could be extended. A vacuum spiral orbit tribometer (SOT) was modified to accept a device to supply re-lubrication during testing. It was successfully demonstrated that a liquid lubricant (Pennzane (Registered Trademark)/Nye 2001A) could be evaporated into a contact during operation, lowering the friction coefficient and therefore extending the life of the system.

Jansen, Mark J.↗

Tribological Properties of a Pennzane(Registered Trademark)-Based Liquid Lubricant (Disubstituted Alkylated Cyclopentane) for Low Temperature Space Applications

The tribological properties of a disubstituted alkylated cyclopentane, Pennzane (registered) Synthesized Hydrocarbon Fluid X-1000, are presented. This compound is a lower molecular weight version of the commonly used multiply alkylated cyclopentane, Pennzane X-2000, currently used in many space mechanisms. New, lower temperature applications will require liquid lubricants with lower viscosities and pour points and acceptable vapor pressures. Properties reported include: friction and wear studies and lubricated lifetime in vacuum; additionally, typical physical properties (i.e., viscosity-temperature, pour point, flash and fire point, specific gravity, refractive index, thermal properties, volatility and vapor pressure) are reported.

Venier, Clifford↗

Tribological Performance of Some Pennzane(Registered Trademark) Based Greases for Vacuum Applications

Commercial greases for space applications usually fulfill the requirements imposed by the severe conditions of use. The main requirement is their ability to create an EHL film, boundary film, or both under speed, load and temperature conditions that the mechanisms will operate. Three greases, all based on a multiply alkylated cyclopentane (Pennzan(R)) base oil, were studied. The thickeners were an n-octadecylterephthalamate soap, a lithium soap, and a urea derivative. A Four-Ball Tribometer and a Spiral Orbit Tribometer were employed to evaluate the greases under ultrahigh vacuum. Results indicated that all three greases yielded very low wear rates and extended lifetimes. In addition, routine physical property data is reported for each grease.

Marchetti, Mario↗

Preliminary Evaluation of Greases for Space Mechanisms Using a Vacuum Spiral Orbit Tribometer

Most currently used greases for space applications are based on perfluoropolyalkylethers (PFPE) and multiply alkylated cyclopentane (MAC) oils. Evaluation of the greases includes outgassing properties, rheological behavior, and particularly the ability to create EHL films under conditions as close as possible to an actual application. A spiral orbit tribometer (SOT) has been developed to conduct accelerated tests under realistic conditions. The SOT was employed to evaluate two greases used in space mechanisms: a PFPE oil with polytetrafluoroethylene (PTFE) thickener, and a multiply alkylated cyclopentane oil with n-octadecylterephthalamate soap. The results from the greases are in agreement with results previously obtained with the base oils.

Marchetti, Mario↗

Evaluation of Temperature and Material Combinations on Several Lubricants for Use in the Geostationary Operational Environmental Satellite (GOES) Mission Filter Wheel Bearings

A bearing test apparatus was used to investigate lubricant degradation rates and elastohydrodynamic transition temperatures for several perfluoropolyether (Krytox) formulations, a pentasilahydrocarbon, and a synthetic hydrocarbon (Pennzane 2001 A) in an MPB 1219 bearing, which is used in the geostationary operational environmental satellite (GOES) mission filter wheel assembly. Test conditions were the following: 1000-hr duration, 75 C, 20 lb axial load, vacuum level less than 1 x 10(exp -6) Torr, and a 600-rpm rotational speed. Baseline tests were performed using unformulated Krytox 143AB, the heritage lubricant. Krytox additive formulations showed small reductions in degradation rate. Krytox GPL-105, a higher viscosity version, yielded the least amount of degradation products. Both the silahydrocarbon and Pennzane 2001A showed no signs of lubricant degradation and had ample amounts of free oil at test conclusion.

Jansen, Mark J.↗

The Effects of Acid Passivation, Tricresyl Phosphate Presoak, and UV/Ozone Treatment on the Tribology of Perfluoropolyether-Lubricated 440C Stainless Steel Couples

The boundary-lubrication performance of two perfluoropolyether (PFPE) thin films in the presence of passivated 440C stainless steel is presented. The study used a standard ball on disk (BoD) tribometer in dry nitrogen and a vacuum spiral orbit tribometer (SOT). Stainless steel surfaces were passivated with one of four techniques: high and low temperature chromic acid bath, a tricresyl phosphate (TCP) soak, or UV/Ozone treated for 15 min. After passivation, each BoD disk had a 400A film of Krytox 16256 (PFPE) applied to it. The lifetimes of these films were quantified by measuring the number of sliding cycles before an increase in friction occurred. The lubricated lifetime of the 440C couple was not altered as a result of the various passivation techniques. The resulting surface chemistry of each passivation technique was examined using X-ray photoelectron spectroscopy (XPS). The SOT was used to examine the effects of the TCP treatment on the lubricated lifetime of another PFPE, Brayco 815Z, under rolling conditions. None of the passivation techniques were found to dramatically increase the oxide film thickness or lubricated lifetimes.

Shogrin, Bradley A.↗

Relative Lifetimes of Several Space Liquid Lubricants Using a Vacuum Spiral Orbit Tribometer (SOT)

A vacuum spiral orbit rolling contact tribometer (SOT) was used to determine the relative lifetimes of several unformulated space liquid lubricants. The lubricants tested included a synthetic hydrocarbon (Pennzane 2001 A), three perfluoropolyethers (Krytox 143AC, Fomblin Z25, and Brayco 815Z), three silahydrocarbons (a tri, a tetra, and a penta) and a polyalphaolefin (Nye PAO-100). The SOT simulates the ball motions in an angular contact bearing and tribochemically degrades microgram quantities of lubricant. Test failure is determined when a preset friction coefficient is exceeded. Relative lifetime (orbits/micro-g) is defined as the number of ball orbits to failure divided by the amount of lubricant on the ball. Conditions included 10 to 200 rpm rotational speed, approximately 50 micro-g lubricant, an initial vacuum < 1.3x10(exp -6) Pa, room temperature (approximately 23 C), a mean Hertzian stress of 1.5 GPa, and 440 C stainless steel specimens. Lubricated lifetimes from longest to shortest were Pennzane 2001 A, the silahydrocarbons and the PAO-100, 143AC, ZI-5, and then 815Z. Relative lifetimes compare favorably to full-scale vacuum gimbal bearing tests. The effect of varying the mean Hertzian stress on the lifetime of some of the lubricants was examined.

Jansen, Mark J.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-1) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

This paper describes the results of accelerated and operational life tests on bearings for the Moderate Resolution Imaging Spectroradiometer (MODIS). It also describes the post test analysis of the disassembled bearings. Analysis was performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of three test stations were in very good condition after accumulating 68, 144, and 209 million cycles, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

EHL Transition Temperature Measurements on a Geostationary Operational Environmental Satellite (GOES) Filter Wheel Bearing

The elastohydrodynamic lubrication (EHL) transition temperature was measured for a Geostationary Operational Environmental Satellite (GOES) sounder filter wheel bearing in a vacuum tribometer. Conditions included both an 89 N (20 lb.) hard and soft load, 600 rpm, temperatures between 23 C (73 F) and 85 C (185 F), and a vacuum of approximately 1.3 x 10(exp -5) Pa. Elastohydrodynamic to mixed lubrication started to occur at approximately 70 C (158 F).

Jansen, Mark J.↗