Search NASA⌕ Search

Engineering topics

Jarvis, Jonathan

Publications and source records attributed to Jarvis, Jonathan.

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Complete 6D tracking of a single electron in the IOTA ring

We present the results of the first experiments on 6-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology makes it possible to fully reconstruct turn-by-turn positions and momentums in all three planes for a single particle. Complete experimental particle tracking enables the first direct measurements of dynamical properties, including invariants, amplitude and energy dependence of tunes with exceptional precision, and chaotic behavior.

43 PARTICLE ACCELERATORS↗

Near-infrared noise in intense electron beams

Requirements for the noise in electron beams (NEB) have recently approached the Shot-noise level in some new applications. The density fluctuations of intense beams in the near-infrared (NIR) region are being measured at the Fermilab Accelerator Science and Technology (FAST) facility. The main goal of the experiment is to accurately compare the Shot-noise model with the observations of optical transition radiation (OTR) generated by the gamma=63 electron beam transiting an Al metal surface. In addition, evidence for longitudinal-space-charge-induced microbunching for the chicane-compressed beam was obtained with coherent enhancements up to 100 in the various bandwidth-filtered NIR OTR photodiode signals. With micropulse charges up to 1 nC, the beam parameters are close to those proposed for a stage in an Electron-Ion Collider (EIC) with coherent electron cooling (CEC). In this paper we present the current progress of the NEB project and compare the low electron energy measurements with ImpactX simulations.

43 PARTICLE ACCELERATORS↗

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Complete 6D Tracking of a Single Electron in the IOTA Ring

We present the results of the first experiments on 6-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology makes it possible to fully reconstruct turn-by-turn positions and momentums in all three planes for a single particle. Complete experimental particle tracking enables the first direct measurements of dynamical properties, including invariants, amplitude and energy dependence of tunes with exceptional precision, and chaotic behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved measurements of nonlinear integrable optics at IOTA

Nonlinear integrable optics (NIO) are a promising novel approach at improving the stability of high intensity beams. Implementations of NIO based on specialized magnetic elements are being tested at the Integrable Optics Test Accelerator (IOTA) at Fermilab. One method of verifying proper implementation of these solutions is by measuring the analytic invariants predicted by theory. The initial measurements of nonlinear invariants were performed during IOTA run in 2019/20, however the covid-19 pandemic prevented the full-scale experimental program from being completed. Several important improvements were implemented in IOTA for the 2022/23 run, including the operation at higher beam energy of 150 MeV, improved optics control, and chromaticity correction. This report presents on the improved calibrations of the NIO for nonlinear invariant measurements.

43 PARTICLE ACCELERATORS↗

Measurement of Coherence Length in UndulAtor RAdiation (CLARA): Run 4 Proposal

The goal of the proposed experimental research is to investigate the quantum nature of “a particle in a ring” by studying a single 135-MeV electron, circulating in the IOTA storage ring and interacting with an undulator through single- and multi-photon emissions. The focus of this proposal will be two-photon undulator emissions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of the Optical Stochastic Cooling at the IOTA Storage Ring Using ELEGANT

In support of the Optical Stochastic Cooling (OSC) experiment at IOTA, we implemented a high-fidelity model of OSC in ELEGANT. The element is generalizable to any OSC experiment and captures three main behaviors; (i) the longitudinal time of flight OSC, (ii) the effects between the transverse motion of particles in the beam and the transverse distribution of undulator radiation, and (iii) the incoherent contributions of neighboring particles. Together these produce a highly accurate model of OSC and were benchmarked using the results from the IOTA OSC experiment.

43 PARTICLE ACCELERATORS↗

Characterization and Simulation of Optical Delay System for the Proof-of-Principle Experiment of Optical Stochastic Cooling at IOTA

The Optical Stochastic Cooling (OSC) experiment at Fermilab’s IOTA storage ring uses two undulators to cool the beam over many turns. The radiation emitted by electrons in the first undulator is delayed and imaged in the second undulator where it applies a corrective energy kick on the electrons. Imperfections in the manufacturing of the delay plates can lead to a source of error. This paper presents the experimental characterization of the absolute thickness of these delay plates using an interferometric technique. The measured "thickness maps" are implemented in the Synchrotron Radiation Workshop (SRW) program to assess their impact on the delayed radiation pulse.

43 PARTICLE ACCELERATORS↗

Numerical Modelling of the Optical Stochastic Cooling Experiment at IOTA

A proof-of-principle optical-stochastic cooling (OSC) experiment is currently in its commissioning phase at the Fermilab’s IOTA ring. In support of this experiment, we recently implemented an OSC element in the ELEGANT tracking program. The model, based on a semi-analytic description of OSC [*], supports the simulation of a large number of macroparticles (10⁴-10⁶) over many turns (10⁶). This paper showcases the simulation capabilities to investigate the beam dynamics in the presence of cooling (or self-interacting radiation field in general) and quantify the impact of various sources of error (e.g. transverse and phase jitter), guide data analysis.

43 PARTICLE ACCELERATORS↗