Search NASA⌕ Search

Engineering topics

Jason Hartwig

Publications and source records attributed to Jason Hartwig.

At least 19 records

Decoupling Surface Topography from Gravitational Acceleration in Cryogenic Pool Boiling

Boiling heat transfer is governed by a complex interplay between surface conditions and gravitational acceleration. To isolate the sole effects of gravity, we investigated the pool boiling characteristics of liquid nitrogen on atomically smooth silicon dioxide (SiO 2 ) surfaces under terrestrial (1-g) and reduced gravity (0±0.02 g) conditions achieved via parabolic flight. Our results quantify a drastic reduction in the critical heat flux (CHF) in reduced gravity, decreasing from 16.15 W/cm 2 at 1-g to 5−6 W/cm 2 at μ-g due to the suppression of buoyancy. Conversely, we observed a distinct increase in the heat transfer coefficient (HTC) in the reduced gravity condition prior to CHF. By utilizing a surface with a maximum peak-to-valley height of ≈36.7 nm and low contact angle hysteresis (<10°), we confirm this HTC enhancement is an intrinsic response to the gravitational environment, decoupled from surface-defect-induced nucleation. These findings demonstrate that the influence of surface topography is significantly more prominent in reduced gravity than in terrestrial conditions, providing a critical baseline for rationalizing the design of cryogenic thermal management systems in space and quantum applications.

Liquid nitrogen↗

Investigating Dual Electrospinning as a Means of Enhancing Passive Thermal Control Coatings for Cryogenic Propellant Storage in Extraterrestrial Environments

Passive thermal control is necessary as space exploration becomes increasingly widespread. Materials with superior optical properties (high solar reflectance and infrared emittance) are critical for passive thermal control because they can reject most of the incident solar radiation and promote thermal emission from cryogenic propellant storage tanks, enabling the extraterrestrial storage of cryogens. We have demonstrated in previous studies that electrospun nanofibers exhibit exceptional optical properties, offering significant benefits for passive radiative cooling in space. Particularly, electrospun polyvinylidene fluoride-co-hexafluoropropylene PVDF-HFP nanofibers demonstrate exceptionally high solar reflectance (>99%) and strong thermal emittance (measured at ~300 K). However, they exhibit nanostructural changes in the presence of atomic oxygen, which is prevalent in Low Earth Orbit. This study focuses on creating a unique blend of polymeric (PVDF-HFP) and ceramic-based (silica) nanofibers by leveraging the chemical stability and atomic oxygen resistance of silica, using the dual electrospinning manufacturing method. This approach aims to preserve the structural properties of the polymeric counterpart without compromising its optical performance, thereby providing an innovative method for manufacturing environmentally resilient passive thermal control nanofibers with desirable optical and thermal control functionalities for extraterrestrial storage of cryogenic propellants.

Chieloka Ibekwe↗

Assessing the Adhesion of Nanofibrous PVDF-HFP as Passive Thermal Control Coatings for the Extraterrestrial Storage of Cryogenic Propellants

Cryogenic propellant passive thermal management techniques in space are essential complements to active thermal management methods, helping reduce absolute dependence on the latter. Particularly, materials with superior optical properties (high solar reflectance and infrared emittance) would be beneficial for passive thermal control to reject most of the incident solar radiation and enhance thermal emission from the storage tank, leading to self-cooling. We developed a nanofibrous, porous passive thermal control material by electrospinning polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) co-polymer onto an aluminum foil substrate. The material exhibits a very high solar reflectance (>99%) and infrared emittance (~86%) when characterized in the ultraviolet-visible-near infrared and mid-infrared wavelengths. This study focuses on the adhesion of the nanofibrous PVDF-HFP to the substrate. We incorporated in-lab fabricated and commercial adhesives, under normal room conditions, between the nanofibers and the aluminum foil substrate to improve their adhesion. Some samples were also exposed to space-like conditions – vacuum and thermal cycling, to investigate their effects on the strengths of adhesives. Subsequently, adhesion peel tests were conducted on all the samples to assess the peel strengths of the bonds. Peel test strengths after space environment conditioning of the adhesives were generally higher than those observed in the pristine, unaged samples. The results are discussed in this study.

Chieloka Ibekwe↗

NASA Glenn/Korea Aerospace Research Institute Technical Interchange Meeting

This is a compilation of NASA Glenn presentation materials as part of the NASA Glenn/Korea Aerospace Research Institute Technical Interchange Meeting in August, 2024. NASA presentations cover Artemis, engines, cryogenic fluid management, microgravity and ISS sciences, extreme materials, and power.

Michael Meyer↗

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig↗

Cryogenic Flow Boiling in Microgravity: Effects of Reduced Gravity on Two-Phase Fluid Physics and Heat Transfer

With the growing interest in space exploration, cryogenic technologies involving two-phase flow and heat transfer are in high demand to successfully procure advanced space applications such as fuel depots and nuclear thermal propulsion (NTP) systems for deep space missions. However, the unique and extreme thermal properties of cryogenic fluids introduce distinct flow boiling fluid physics and energy transport phenomena, which differ significantly from those observed with conventional fluids. Understanding the unique two-phase physics in cryogenic flow boiling remains an ongoing challenge. Furthermore, the lack of readily available microgravity cryogenic steady-state heat transfer data hinders the assessment of gravitational effects on cryogenic flow boiling. This study aims to elucidate the gravitational effects on two-phase fluid physics and heat transfer by conducting the first-ever experimental measurement of cryogenic flow boiling performance using a steady-state heated method in a reduced gravity environment. Parabolic flight experiments were performed to acquire both heat transfer measurements and high-speed video of interfacial behaviors, under varying gravity levels (microgravity, hypergravity, Lunar gravity, and Martian gravity). The experiments involved flow boiling of liquid nitrogen (LN 2 ) with a near-saturated inlet along a circular heated tube of dimensions 8.5-mm inner diameter and 680-mm heated length. The operating parameters varied are mass velocity of 398.3 - 1342.8 kg/m2s, inlet quality of -0.08 to -0.01, and inlet pressure of 413.68 - 689.48 kPa. Captured microgravity flow patterns range from bubbly to annular, all having vapor structures that are larger than those under higher gravity levels. Under microgravity, absence of buoyancy yields symmetrical vapor structures without flow stratification, laying a physical foundation for the distinct two-phase heat transfer trends during LN 2 flow boiling in microgravity. Transient data collected during the flight parabolas exhibited decreasing heated wall temperature as the aircraft transitioned from hypergravity to microgravity phases. The temperature variation indicated an enhancement in flow boiling heat transfer with decreasing gravity levels and a reduction with increasing gravity levels. The effect of reduced gravity on cryogenic flow boiling heat transfer coefficient (HTC) is discussed based on steady state heat transfer analysis. Seminal HTC correlations are evaluated against the measured microgravity HTC data, of which one is identified for superior accuracy in predicting microgravity data. Finally, a new HTC correlation is proposed to improve accuracy of microgravity predictions, yet there still exists room for further improvement with future terrestrial flow boiling experiments at different flow orientations relative to Earth gravity.

Microgravity↗

Thermal Desktop Modeling of the 2016 CRYOTE-2 Tank Chill and Fill Tests

The storing and transfer of cryogenic propellants is an enabling technology for NASA as it moves to expand future missions into low Earth orbit (LEO) and beyond. The transfer of cryogenic propellants is of particular interest because it has never been successfully demonstrated in microgravity. Several ground tests have been conducted in past decades examining various tank chilldown and fill methods. Creating accurate models using these historical datasets is a vital step toward developing appropriate modeling tools to form pre-test predictions for eventual flight and ground tests of various novel injector concepts. The goal of this work was to create a working model in Thermal Desktop using data from the CRYOTE-2 experiments whose purpose was to demonstrate the chill and fill process in a spherical receiver tank parametrically examining the effect of injection method, receiver tank initial wall temperature and initial state, supply pressure, and mass flow rate on the NVF process. These tests were conducting using liquid nitrogen with different injectors with different injection patterns. The focus of the current work is on one particular spray nozzle. The pressure rise inside the tank, the fill level, and the change in the outside wall temperature were all tracked and compared with test data. The Thermal Desktop model was able to accurately predict each of these metrics for this nozzle within 11.0%, 22.0%, and 7.0%, respectively.

Cryogenic Tank Chilldown↗

Two-Dimensional Network Flow Modeling of No-Vent Tank Filling of A Cryogenic Tank With Thermo-Dynamic Vent System Assisted Injector

A finite volume-based network flow modeling tool, Generalized Fluid System Simulation Program (GFSSP), was used to simulate the no-vent filling of a cryogenic tank with a thermodynamic vent system assisted injector. The tank was discretized into nodes in the radial and axial directions to calculate two-dimensional axisymmetric flow with heat transfer between the solid wall and fluid. The nodes are connected by branches where momentum equations are solved to calculate the flowrates. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The energy conservation equations at the solid nodes were solved to calculate the temperature of the solid wall. The system of equations was solved by a combination of successive substitution and simultaneous Newton-Raphson method. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around the spray droplets, c) condensation of vapor at the interface of the cooled injector and ullage, and d) condensation at the liquid-vapor interphase. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data. The paper also presents the effect of nodal discretization by comparing the results of the 1D and 2D models and examines the effect of the droplet diameter on tank filling.

Nodal Model↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Helium

Understanding two-phase cryogenic propellant behavior is key to enabling technologies for future spaceflight missions. Developing accurate models of two-phase flow phenomena, particularly flow boiling in the heating configuration is relevant to the propellant transfer process both in microgravity and on other planetary surfaces. Currently there is a need for more accurate, direct cryogenic data anchored models for various boiling phenomena. Recently, universal correlations for cryogens flowing in heated tubes have been developed for a wide variety of fluids, thermodynamic conditions, and various regimes across the boiling curve, and have been patched to provide a smooth, continuous predictive curve. This paper demonstrates how these correlations have been ported into Thermal Desktop to improve predictive performance. To test the validity of the new correlations, Thermal Desktop is validated against a historical dataset of flow boiling experiments in the heating configuration using liquid helium. Based on results, the new correlations show a substantial improvement over the original built-in flow boiling correlations in Thermal Desktop in predicting the wall temperature as a function of preponderant parameters for this quantum fluid.

cryogenic propellant transfer↗

Development and Testing of Femtosecond Laser Surface Processing (FLSP) Treated Guide Vanes for Application to Advanced Cryogenic Liquid Acquisition Devices

Liquid Acquisition Devices (LADs) are used inside propellant tanks in microgravity to collect liquid propellant to move towards the sump or outlet of a tank during expulsion or transfer. In microgravity, vehicle thrusters can produce necessary phase separation, but in the absence of thrust, surface tension is the driver of fluid behavior. Liquid in microgravity will tend to form a sphere to minimize surface area. If a LAD can be made more “attractive” to a propellant (omniphilic), then it should perform its function more effectively. This paper presents preliminary results on using femtosecond laser surface processing (FLSP) to change the wetting properties of a vane LAD. FLSP can make metals superhydrophilic or omniphilic; by controlling the applied laser parameters, the resulting micro and nanoscale surface features can be tailored to control and optimize hydrophilic/omniphilic properties. Two LAD galleries with guide vanes were recently fabricated, a control sample and an FLSP-treated sample. The LADs were ground tested and also implemented in a parabolic flight experiment. Based on contact angle and roll-off angle measurements of the surface-treated vane, FLSP appears to be a promising technique to improve efficiency of LADs

Liquid Acquisition Devices↗

Test data analysis of the thermodynamic vent system-augmented top spray injector liquid nitrogen transfer experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

No-vent Fill↗

Numerical Modeling and Design of Gaseous Propellant Acquisition System for the Triton Hopper

Triton, the largest moon around Neptune, is a captured Kuiper Belt Object with a dynamic rarified atmosphere, active geysers, and unique “cantaloupe” like terrain. Little is known about Kuiper Belt Objects in the scientific community with most of the information coming from Pluto. Currently, NASA is designing an unmanned probe to explore the atmosphere and surface of Triton. This vehicle is unique in that it repeatedly takes off and lands (hops) using nitrogen propellant collected from its surroundings on Triton. This paper presents preliminary conceptual system design and numerical modeling of the atmospheric collection process. Four concepts are presented: a cryocooler-based system, a pump-based system, a sublimation and pump-based system, and a cryocooler and sublimation system. Numerical modeling takes into account the mass and energy transfer between all the relevant nodes in the system and is able to calculate the amount of nitrogen ice collected and ice accumulation rate as a function of time for each concept. The models are ultimately used to assess the feasibility of traversing from equator to pole in under two years using a gaseous propellant acquisition system for the Hopper.

Hopper↗

Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient↗

Analytical Model for Steady Flow through a Finite Channel with One Porous Wall with Arbitrary Variable Suction or Injection

This paper presents an exact solution of two-dimensional laminar flow through a finite length channel with one porous wall. It improves upon previous solutions by (1) satisfying the no-slip boundary condition at the channel dead end, (2) adding a turbulent term to the porous wall boundary condition, (3) allowing for arbitrary variable suction or injection across the porous wall, and (4) model validation against new cryogenic liquid hydrogen and oxygen experimental data. Of particular interest in the current work is the modeling of cryogenic propellant flow through a porous liquid acquisition device (LAD) screen and channel inside a propellant tank. First, a detailed review of the literature is presented for previously attempted solutions to channel flow with one porous wall. Next, the governing equations, boundary conditions, and model assumptions are used to derive the analytical flow solution and present general model results for pressure and velocity fields within the channel. Then, the model solution is compared with horizontal LAD channel flow data in liquid oxygen as well as vertical LAD channel flow data in an inverted outflow configuration in liquid hydrogen. Model results are used to update the static cryogenic bubble point pressure model with a dynamic bubble point term which factors in enhanced convection and cooling at the screen during propellant outflow. Convective heat transfer at the LAD screen during outflow is also quantified by comparing model and data. The new analytical flow solution with the dynamic bubble point model is shown to compare well with available cryogenic experimental data

Navier Stokes Equations↗

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device↗

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot↗

CFD Modeling of Cryogenic Chilldown in a Complex Channel under Normal and Low Gravity Conditions

Future NASA architectures have baselined cryogenic propulsion systems as well as cryogenic fluid management to support lunar missions and ultimately to support future missions to Mars. These missions will require chilling hardware down prior to engine restart as well as chilling lines and tanks prior to transferring and refueling these propulsion elements in orbit. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these chilldown processes can be used to reduce system and propellant mass as well as mission risk.

CFD↗