Search NASA⌕ Search

Engineering topics

Jason Nelson

Publications and source records attributed to Jason Nelson.

Chemistry of Ionic Silver and Implications for Design of Potable Water Systems

Ionic silver (Ag+) at approximately 400 µg/L is proposed as an ingestible biocide for potable water systems in future human spacecraft. This paper investigates the underlying chemistry of the silver ion at potable concentrations and its interactions with other solutes and surfaces. This chemistry evaluation will elucidate ionic silver behavior in potable water systems and enable design optimization to minimize ionic silver depletion during long duration crewed and uncrewed segments of missions. Ionic silver can be lost from the water phase to the water-solid interface via adsorption as the cation and oxidation-reduction reactions with passivation defects. The adsorption and oxidation-reduction reactions of heritage piping materials used on spacecraft – stainless steel 316L, titanium, Inconel 718, and Teflon flex hoses – are considered. Conceptual models of adsorption isotherms and pH adsorption edges are applied to understand the role of pH and the surface-to-volume ratio of pipes and tanks on the partitioning of ionic silver between the aqueous and the solid phase during aging. The effect of repeated exposure-aging to an Ag+ containing solution of two passivated alloys (316L and Inconel 718) is evaluated to determine if an equilibrium concentration of ionic silver in the potable range is attainable for a given alloy and surface-to-volume ratio. Aging unpassivated and passivated 316L reduced the ionic silver depletion rate relative to first time exposures, but the same beneficial effect was not observed for Inconel 718.

Water↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

Early Results from a Broad Compatibility Study of Various Materials with Ionic Silver Biocide

Ionic silver is baselined for microbial control in spacecraft potable water systems forfuture exploration missions, but materials compatibility analysis is required to evaluate thepassive depletion of ionic silver concentration onto wetted material surfaces over time.Various articles concerning such testing have been published that examine interactions withwater containing ionic silver biocide, but most tests have focused on only a couple ofmaterials each and comparing results of different evaluations to one another has provedchallenging.This paper reports the first results from static exposure testing of a large arrayof material coupons to a 400 parts per billion (ppb) aqueous silver fluoride (AgF) solution,using a surface to volume ratio of approximately 2 cm-1. The test is designed in two mainstages. Stage 1 is a one-week screening to evaluate silver uptake. Materials that performmodestly to well after that week are promoted to Stage 2, which is a longer test with periodicsampling to examine the silver uptake rates over time; these samples are evaluated for otherwater quality parameters in addition to the remaining silver concentration. In a tangentialinvestigation, select materials that take up some silver in Stage 1 may be “aged” by repeatingthe Stage 1 test to determine whether repeated exposure reduces silver uptake rate, andsuccessfully aged materials may then continue to Stage 2 testing. The materials under testinclude metallic and polymeric materials with various surface finishes, treatments, andcoatings, as well as select other materials historically used in spacecraft water systems. Thistest began in August 2019, and thus only includes early results; future follow-on papers willinclude additional results as the test progresses. The ultimate goal builds a broad, easilycomparable data set that can be used to guide material selections for silver biocide-compatible spacecraft water system design.

Silver Biocide↗

Broad Compatibility Study of Polymeric Materials with Ionic Silver Biocide, Part I

NASA is considering ionic silver as a residual biocide for use in potable water systems being planned for future exploration spacecraft. Compatibility of the biocide with the system’s wetted-materials of construction remains a challenge. Due to the relatively inert nature of plastics, their use in varied water system applications may offer unique opportunities to address many biocide compatibility issues. A 2020 ICES paper described a “Stage 1” assessment of several polymeric materials, in which coupons having a 2 cm 1 surface to volume ratio were exposed to solutions of 400 parts per billion (ppb) aqueous silver fluoride (AgF) for one week. In this current paper, additional Stage 1 test results are presented for select epoxies and lubricants applied on silver-inert substrates. The coupon exposure studies were also expanded to a duration of 5 weeks for the “well-behaved” Stage 1 plastics previously reported: those exhibiting silver losses above 10% and less than 50%. For this type of Stage 2 testing, silver biocide solution samples are taken from three separate (and not previously-sampled) coupon containers after 3 days, and 2, 3, 4, and 5 weeks of exposure. "Very well-behaved" Stage 1 plastics will be tested in the same manner over one year, with longer sample intervals; early-period results are included here. In addition, for select materials, the coupons were “aged” by refilling test containers with fresh AgF and observing the respective silver uptake over similar Stage 2 test durations. For all test series, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and ion-selective electrode (ISE) analyses were used to determine total and ionic silver (Ag+) concentrations, respectively. Additional sample analyses for Stage 2 tests includes total organic carbon (TOC), pH, conductivity, and oxidation-reduction potential (ORP). Ultimately, these early compatibility studies will be used to guide future material selections for developing silver biocide-compatible spacecraft water systems.

Silver Biocide↗