Search NASA⌕ Search

Engineering topics

Jelinsky, Patrick

Publications and source records attributed to Jelinsky, Patrick.

28 records · Page 2

Two normal incidence collimators designed for the calibration of the extreme ultraviolet explorer

Two Dall-Kirkham, normal incidence collimators have been designed to calibrate the imaging properties of the Extreme Ultraviolet Explorer over the wavelength region from 114 to 2000 A. The mirrors of the short-wavelength, 25-cm diameter collimator are superpolished Zerodur which have been multilayer coated for optimal reflectivity at 114 A. The mirrors of the long-wavelength, 41.25-cm diameter collimator are gold coated Zerodur for high reflectance above 300 A. The design, performance, and future use of these collimators in the extreme ultra-violet is discussed.

Jelinsky, Sharon R.↗

Low reflectance EUV materials - A comparative study

A study has been undertaken of the performance characteristics of a variety of surfaces and surface treatments for use on baffle materials in Extreme UV Explorer instrumentation, in order to ascertain which materials performed with the least overall scattering between 300 and 1200 A and thereby minimize this important background source. Seven scattering samples were measured: bead-blasted aluminum treated with alodine 600, bead-blasted aluminum, Kel-f, etched molybdenum, nickel-plated etched molybdenum, bead-blasted 304 stainless steel, and bead-blasted aluminum painted with Chemglaze Z-306. Attention is given to total reflectance of each material plotted against the graze angle for 304, 584, and 1216 A.

Jelinsky, Patrick↗

Contamination control approach for the Extreme Ultraviolet Explorer satellite instrumentation

The Extreme Ultraviolet Explorer will perform an all-sky survey and spectroscopic observations over the wavelength range 80-900A. Hydrocarbon and particulate contamination will potentially affect the throughput and signal to noise ratio of the signal detected by the instruments. A witness sample program is here used to investigate and monitor the effects of specific contaminants on EUV reflectivity. Witness samples were intentionally contaminated with thin layers of pump oil. An oil layer 150 A thick was applied and found to evaporate over 8 hours. The EUV reflectivity and imaging properties were then measured and found to be acceptable for grazing angles between 5 and 30 deg. In a second test, layers 500 A thick were deposited and then allowed to evaporate in vacuum; once the oil had evaporated to at least 350 A, the final sample reflectivity was degraded less than 10 percent, but the image was degraded severely by scattering. An outline of the contamination control program is also presented.

Mrowka, Stan↗

An overview of the extreme ultraviolet explorer and its scientific program

NASA's Extreme Ultraviolet Explorer (EUVE) will carry out an all-sky survey from 8 to 90 nm in four bandpasses; the limiting sensitivity will be between 2 to 3 orders of magnitude fainter than the hot white dwarf HZ 43. A deep survey will also be carried out along the ecliptic which will have a limiting sensitivity of 1 to 2 orders of magnitude fainter than the all-sky survey in the bandpass from 8 to 50 nm. The payload also includes a spectrometer which will be used to observe the brighter sources found in the surveys with a spectral resolution of 1 to 2 A.

Malina, Roger F.↗

Reflectivity of silicon carbide in the extreme ultraviolet

Reflectivity and scattering measurements on samples of SiC manufactured by a variety of processes. Measurements were made from near-normal to grazing incidence at wavelengths in the range of 114 to 1216 A. CVD SiC displays the highest reflectivity at EUV wavelengths and normal incidence. At grazing incidence, Si-rich samples show reflectivity cutoff identical to polycrystalline Si. From the limited data available for single-crystal material, it is concluded that CVD material has comparable performance.

Mrowka, Stanley↗

An extreme ultraviolet telescope with no soft X-ray response

While EUV grazing incidence telescopes of conventional design exhibit a substantial X-ray response as well as an extreme UV response, and existing bandpass filters for the transmission of radiation longward of 400 A also transmit soft X-rays, the grazing incidence telescope presented suppresses this soft X-ray throughput through the incorporation of a Wolter Schwarzschild Type II mirror with large graze angles. The desirable features of an EUV photometric survey telescope are retained. An instrument of this design will be flown on the EUE mission, in order to make a survey of the sky at wavelengths longer than 400 A.

Finley, David S.↗

A Penning discharge source for extreme ultraviolet calibration

A Penning discharge lamp for use in the calibration of instruments and components for the extreme ultraviolet has been developed. This source is sufficiently light and compact to make it suitable for mounting on the movable slit assembly of a grazing incidence Rowland circle monochromator. Because this is a continuous discharge source, it is suitable for use with photon counting detectors. Line radiation is provided both by the gas and by atoms sputtered off the interchangeable metal cathodes. Usable lines are produced by species as highly ionized as Ne IV and Al V. The wavelength coverage provided is such that a good density of emission lines is available down to wavelengths as short as 100A. This source fills the gap between 100 and 300A, which is inadequately covered by the other available compact continuous radiation sources.

Finley, David S.↗

Calibration of a 1 meter diameter normal incidence extreme ultraviolet telescope/spectrometer

A 1-meter normal incidence telescope, with a normal incidence concave diffraction grating spectrometer at its focus, has been developed. The instrument's spectral coverage is 350 to 1150A with a spectral resolution of 5A and a peak effective area of 6 sq cm at 500A. The instrument was launched on an Aries sounding rocket on November 27, 1983 in an effort to determine the hydrogen and helium abundance in the local interstellar medium. A description of this instrument, with the primary emphasis on the methods used to calibrate it, is presented.

Jelinsky, Patrick↗

Calibration of the thin film filters to be used on the Extreme Ultraviolet Explorer Satellite

The methods of calibrating the filters used on the Extreme Ultraviolet Explorer (EUVE) astronomical satellite are described. EUVE will conduct the first all-sky survey in the entire EUV band. The measurement of the filters' transmission properties from the soft X-ray to the far UV using a grazing incidence monochromator is discussed. A particle ingress test to determine the ability of the filters to inhibit energetic particles in earth orbit from entering the detector and increasing the background is described. Problems encountered in calibrating these four filters are also presented.

Vallerga, John↗