Search NASA⌕ Search

Engineering topics

Jenket, Don

Publications and source records attributed to Jenket, Don.

Selection and Use Considerations for Laser Power Photovoltaic Receivers

III-V PV receivers provide high performance over wide range of application conditions. Operating conditions including irradiance and cell temperature must be accounted for. Very high efficiencies demonstrated for small GaAs devices. Potential for significant future advances in performance, especially for other wavelengths and for cost.

GaAs↗

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

Field Aging Testbed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at NREL to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU Lithium-ion and Avalon vanadium-redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Lithium Ion battery systems performing within expectation, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate battery capacity may degrade by 20%-35% over 10 years.

25 ENERGY STORAGE↗