Search NASA⌕ Search

Engineering topics

Jennifer G Williams

Publications and source records attributed to Jennifer G Williams.

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.

Mass Spectrometry↗

Developing Mass Spectrometry for Water Quantitation and Volatiles Analysis from In-Situ Regolith

With a revived focus to create a sustainable hu-man presence on the moon, and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential [1]. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable in-dependent operation of missions while reducing the dependence on the complex supply chain created between the Earth, the moon and Mars. One of the most critical resources that has been identified for ISRU on the lunar surface is water [2]. Water is a versatile resource that can be used in various space operations, such as ra-diation shielding and conversion to oxygen (O2) for propellant [3,4]. One of the most water rich resources is thought to be within the regolith lo-cated in the permanently shadowed regions (PSR) of the Moon; several upcoming missions, such as PRIME-1 and VIPER, are already sched-uled to confirm this hypothesis [5,6]. However, there are currently no missions planned to quanti-fy the abudance of water at these regions. The quantity of water contained in the ice will inform and help the development of future ISRU plants and operation. Water and other volatile gases can be detect-ed upon controlled heating of icy lunar regolith for an accurate quantification of water. This method is similar to thermogravimetric analysis, which was used to analyze Apollo lunar regolith sam-ples. However, losses via sublimation/evaporation or contamination may have occurred with the samples due to the transit and exposure to the terrestrial environment. Furthermore, water would not be expected for these samples since they were not collected from a PSR. Thus, for more accurate results, icy lunar regolith should be ana-lyzed in situ to provide the most representative composition of both water and other volatile gas-es. The Light Water Analysis and Volatile Extract (LightWAVE) project aims to address this knowledge gap. A system has been developed to collect, heat and analyze evolved gases from lu-nar regolith on the lunar surface. The gases will be analyzed by a modified commercial off the shelf (COTS) residual gas analyzer (RGA) quad-rupole mass spectrometer. Evolved gases from heated regolith samples can be identified by the observed mass-to-charge (m/z) ratios, and the peak intensities correlate to the abundances of the observed gases for quantitation. Therefore, our group is developing a calibration methodology utilizing a COTS RGA to quantitate water from in-situ regolith samples on the lunar surface. The partial pressure of water and ideal gas law will be used to quantify the total water evolved from a regolith sample. Here we present our methodol-ogy for the design and calibration for water quan-titation using a COTS RGA.

Nilab Azim↗

Real-time Contaminant Evolution from a CO 2 Scrubber

Spaceflight requires recycling and revitalization of cabin air within the spacecraft during missions. Marshall Space Flight Center’s (MSFC) Environmental Control and Life Support Systems Engineering Development Branch (ES-62), develops and tests novel regenerative life support systems, supports the International Space Station (ISS) operations, and plans life support for future missions, such as Gateway and Mars transit.

Jennifer G Williams↗

Design of an Adsorption Bed for Exploration Trace Contaminant Control

The state-of-the-art in long mission duration spacecraft trace contaminant control processes relies on physical and chemical adsorption for contaminant removal. Target species for adsorption include low and semivolatile organic compounds while chemisorption is utilized for metabolic ammonia control. When adsorption is employed in conjunction with a high temperature oxidation process, a complementary impact on cabin air quality may be realized. The adsorption bed also serves to guard the downstream oxidation catalyst from foulants and potential poisons which may decrease its lifetime and activity. To this end, a packed adsorption guard-bed was sized to control a statistical contaminant load model over a simulated Mars transit mission duration. The updated load model incorporates flight air-quality data and contemporary metabolic source emission literature. The guard-bed was operated in tandem with an exploration prototype thermal catalytic oxidizer. The exploration guard-bed prototype included design considerations from recent flight technology demonstrations and changes intended to improve compatibility with enriched oxygen exploration cabin environments as compared to the prior-art of contaminant control system design.

Trace Contaminant Control↗