Jensen, Chris L.

Publications and source records attributed to Jensen, Chris L..

Characterization of Aluminum Metal Powders for Plutonium-238 Program

As part of radioisotope thermoelectric generator (RTG) production for power sources in deep space exploration, Oak Ridge National Laboratory (ORNL) produces plutonium-238 ( 238 Pu). To produce 238 Pu, neptunium-237 ( 237 Np) targets are fabricated at ORNL and subsequently irradiated at the High Flux Isotope Reactor (HFIR) at ORNL and the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Specifically, current flowsheets utilize neptunium dioxide ( 237 NpO 2 ) targets. Aluminum (Al) powder is blended with 237 NpO 2 target material to improve thermal conductivity during irradiation. The current composition of 237 NpO 2 /Al pellets (i.e., cermets, or ceramic–metallics) is 20% 237 NpO 2 , 70% Al, and 10% void space. Al powders utilized by the 238 Pu program are high-fired under vacuum before blending into targets. The primary objective of this work is to measure the physical, chemical, and thermal properties of Al before and after the high-firing process. Properties of interest include the morphology, surface texture, particle size, crystal phase(s), and thermal conductivity of the material. These properties are measured with existing materials characterization equipment at ORNL, including powder x-ray diffraction (pXRD), scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS), laser flash analysis (LFA), and thermogravimetric analysis (TGA). A secondary objective of this work is to compare the Al powders before and after the high-firing procedure to determine the effects of high-firing on chemical, physical, and thermal properties and to determine the efficacy of the high-firing process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Guidance on Use of the Netzsch LFA 447 Nanoflash for Measurement of Ceramic-Metallic (Cermet) Pellet Specimen

The Netzsch LFA 447 Nanoflash Instrument uses the laser flash method to measure thermal diffusivity of a material. Thermal conductivity can be determined if specific heat and density are known for that material. The 238 Pu Supply Program is interested in re-establishing the capability to determine thermal diffusivity and thermal conductivity of various 237Np Al/cermet samples during heating. The bottom side of a plane parallel sample is heated by an energy pulse from a light source (in this case a xenon lamp). An infrared (IR) detector is on the top side of the sample which detects the time dependent temperature rise of the sample due to the energy input from the xenon lamp. The LFA 447 Nanoflash is user-friendly, simple to operate, and has minor sample preparation which will allow technicians to be trained easily on its use. When using the multi-property measurement option, the LFA 447 Nanoflash can determine both thermal diffusivity and specific heat which means only density is needed to identify the thermal conductivity of a sample. This equipment is recognized for being highly accurate and having fast test times, replacing steady-state methods which have proven to be difficult and much slower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Guidance on Use of the Linseis Vertical Dilatometer L75

Linseis vertical Dilatometer L75 thermal expansion equipment is a complete system which can be used for measuring change of the absolute length of a sample, determination of the thermal expansion coefficient (CTE), shrinkage, and sintering. The 238 Pu Supply Program is interested in re-establishing the capability to determine CTE and measuring the change of the absolute length of various 237 Np Al/cermet samples during heating. The change in length of the measured sample is recorded using a highly sensitive Linear Variable Differential Transformer (LVDT). The dilatometer is user-friendly and simple to operate which will allow technicians to be trained easily on its use. This equipment was designed to be used specifically for ceramics. It has a highly vacuum tight push rod dilatometer, a high-resolution inductive transducer using innovative and comprehensive temperature controls which provide excellent performance as a measurement system yielding high accuracy, reproducibility, and long-term stability.

07 ISOTOPE AND RADIATION SOURCES↗

Technical Guidance for Creation of 237 NP Irradiation Target Fabrication Packages

This document describes the process used to document the fabrication of irradiation targets that may be inserted into either the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL), or the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The targets are being irradiated to produce 238 Pu (5.48Mev alpha decay, T1/2 = 87.7 y) used in the fabrication of radioisotope thermoelectric generators (RTGs). RTGs powered by 238 Pu are an established power source technology for National Aeronautics and Space Administration space missions where solar power is not viable. The documentation included in fabrication files demonstrates full traceability of all materials, components, and assemblies used to build 237 Np targets. To accomplish this, all documentation (e.g., certified material test reports, weld reports, leak test reports) will be maintained and reviewed throughout materials procurement, component fabrication, and target assembly.

07 ISOTOPE AND RADIATION SOURCES↗