Search NASA⌕ Search

Engineering topics

Jensen, Scott C.

Publications and source records attributed to Jensen, Scott C..

Spectroscopic Signature of Metal-hydroxo and Peroxo Species in K-edge X-ray Absorption Spectra

Metal-dioxygen species are important intermediates formed during dioxygen activations by metalloenzymes in various biological processes, by catalysts in fuel cells, and prior to O 2 evolution by photosystem II. In this work, we focus on manganese-porphyrin complexes using tetramesitylporphyrin ligand (TMP) to explore changes in Mn K-edge X-ray absorption spectroscopy (XAS) associated with the formation of Mn-hydroxide and Mn–O 2 peroxide species. With limited spectroscopic characterization of these compounds, Mn K β X-ray emission spectroscopy (XES), XAS, density functional theory (DFT), and time-dependent DFT (TD-DFT) analysis will enhance our understanding of their complex electronic structure. We show that the shape of the pre-edge in the K-edge Mn X-ray absorption near-edge structure (XANES) can serve as a spectroscopic signature of the Mn III -peroxo formation and thus can be used to track the presence of the side-on peroxide as an intermediate in time-resolved or in situ experiments. In conclusion, our results will help to further summarize the spectroscopic fingerprints for peroxo and hydroxo species, addressing the challenge of identifying the reactive metal species in catalytic reactions.

Extended X-ray absorption fine structure↗

Optimization of stochastic feature properties in laser powder bed fusion

Process parameter selection in laser powder bed fusion (LPBF) controls the as-printed dimensional tolerances, pore formation, surface quality and microstructure of printed metallic structures. Measuring the stochastic mechanical performance for a wide range of process parameters is cumbersome both in time and cost. As such, in this study, we overcome these hurdles by using high-throughput tensile (HTT) testing of over 250 dogbone samples to examine process-driven performance of strut-like small features, ~1 mm 2 in austenitic stainless steel (316 L). The output mechanical properties, porosity, surface roughness and dimensional accuracy were mapped across the printable range of laser powers and scan speeds using a continuous wave laser LPBF machine. Tradeoffs between ductility and strength are shown across the process space and their implications are discussed. While volumetric energy density deposited onto a substrate to create a melt-pool can be a useful metric for determining bulk properties, it was not found to directly correlate with output small feature performance.

316 L stainless steel↗

Process and feedstock driven microstructure for laser powder bed fusion of 316L stainless steel

Here in the pursuit of improving additively manufactured (AM) component quality and reliability, fine-tuning critical process parameters such as laser power and scan speed is a great first step toward limiting defect formation and optimizing the microstructure. However, the synergistic effects between these process parameters, layer thickness, and feedstock attributes (e.g. powder size distribution) on part characteristics such as microstructure, density, hardness, and surface roughness are not as well-studied. In this work, we investigate 316L stainless steel density cubes built via laser powder bed fusion (L-PBF), emphasizing the significant microstructural changes that occur due to altering the volumetric energy density (VED) via laser power, scan speed, and layer thickness changes, coupled with different starting powder size distributions. This study demonstrates that there is not one ideal process set and powder size distribution for each machine. Instead, there are several combinations or feedstock/process parameter ‘recipes’ to achieve similar goals. This study also establishes that for equivalent VEDs, changing powder size can significantly alter part density, GND density, and hardness. Through proper parameter and feedstock control, part attributes such as density, grain size, texture, dislocation density, hardness, and surface roughness can be customized, thereby creating multiple high-performance regions in the AM process space.

316L stainless steel↗

DIY XES-development of an inexpensive, versatile, and easy to fabricate XES analyzer and sample delivery system

The application of X-ray emission spectroscopy (XES) has grown substantially with the development of X-ray free-electron lasers, third and fourth generation synchrotron sources, and high-power benchtop sources. By providing the high X-ray flux required for XES, these sources broaden the availability and application of this method of probing electronic structure. As the number of sources increase, so does the demand for X-ray emission detection and sample delivery systems that are cost effective and customizable. In this work, we present a detailed fabrication protocol for von Hamos X-ray optics and give details for a 3D-printed spectrometer design. Additionally, we outline an automated, externally triggered liquid sample delivery system that can be used to repeatedly deliver nanoliter droplets onto a plastic substrate for measurement. These systems are both low cost, efficient, and easy to recreate or modify depending on the application. A low cost multiple X-ray analyzer system enables measurement of dilute samples, whereas the sample delivery limits sample loss and reproducibly replaces spent sample with fresh sample in the same position. While both systems can be used in a wide range of applications, the design addresses several challenges associated specifically with time-resolved XES (TRXES). As an example application, we show results from TRXES measurements of photosystem II, a dilute, photoactive protein.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray Emission Spectroscopy at X-ray Free Electron Lasers: Limits to Observation of the Classical Spectroscopic Response for Electronic Structure Analysis

X-ray free electron lasers (XFELs) provide ultrashort intense X-ray pulses suitable to probe electron dynamics but can also induce a multitude of nonlinear excitation processes. These affect spectroscopic measurements and interpretation, particularly for upcoming brighter XFELs. Here we identify and discuss the limits to observing classical spectroscopy, where only one photon is absorbed per atom for a Mn 2+ in a light element (O, C, H) environment. X-ray emission spectroscopy (XES) with different incident photon energies, pulse intensities, and pulse durations is presented. A rate equation model based on sequential ionization and relaxation events is used to calculate populations of multiply ionized states during a single pulse and to explain the observed X-ray induced spectral lines shifts. Furthermore this model provides easy estimation of spectral shifts, which is essential for experimental designs at XFELs and illustrates that shorter X-ray pulses will not overcome sequential ionization but can reduce electron cascade effects.

47 OTHER INSTRUMENTATION↗

X-ray emission spectroscopy of biomimetic Mn coordination complexes

Understanding the function of Mn ions in biological and chemical redox catalysis requires precise knowledge of their electronic structure. X-ray emission spectroscopy (XES) is an emerging technique with a growing application to biological and biomimetic systems. Here, we report an improved, cost-effective spectrometer used to analyze two biomimetic coordination compounds, [Mn IV (OH) 2 (Me 2 EBC)] 2+ and [Mn IV (O)(OH)(Me 2 EBC)] + , the second of which contains a key Mn IV =O structural fragment. Despite having the same formal oxidation state (Mn IV ) and tetradentate ligands, XES spectra from these two compounds demonstrate different electronic structures. Experimental measurements and DFT calculations yield different localized spin densities for the two complexes resulting from Mn IV –OH conversion to Mn IV =O. The relevance of the observed spectroscopic changes is discussed for applications in analyzing complex biological systems such as photosystem II. In conclusion, a model of the S 3 intermediate state of photosystem II containing a Mn IV =O fragment is compared to recent time-resolved X-ray diffraction data of the same state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗