Search NASA⌕ Search

Engineering topics

Jeon, YoungMu

Publications and source records attributed to Jeon, YoungMu.

Tailoring tokamak error fields to control plasma instabilities and transport

A tokamak relies on the axisymmetric magnetic fields to confine fusion plasmas and aims to deliver sustainable and clean energy. However, misalignments arise inevitably in the tokamak construction, leading to small asymmetries in the magnetic field known as error fields (EFs). The EFs have been a major concern in the tokamak approaches because small EFs, even less than 0.1%, can drive a plasma disruption. Meanwhile, the EFs in the tokamak can be favorably used for controlling plasma instabilities, such as edge-localized modes (ELMs). Here we show an optimization that tailors the EFs to maintain an edge 3D response for ELM control with a minimized core 3D response to avoid plasma disruption and unnecessary confinement degradation. We design and demonstrate such an edge-localized 3D response in the KSTAR facility, benefiting from its unique flexibility to change many degrees of freedom in the 3D coil space for the various fusion plasma regimes. This favorable control of the tokamak EF represents a notable advance for designing intrinsically 3D tokamaks to optimize stability and confinement for next-step fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of high-performance long-pulse discharge in KSTAR

High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ~2.0 × 10 19 m –3 were chosen by considering the L–H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (~25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta (β P ) state. KSTAR has achieved a long pulse (~90 s) operation with the high performance of β P $\leqslant$ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ~ 1.1, and fraction of non-inductive current (f NI ) $\leqslant$ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ~18% over the time of ~8τ R (current relaxation time, τ R ~5 s) and ~1067τ E,th (thermal energy confinement time, τ E,th ~45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Suppression of toroidal Alfvén eigenmodes by the electron cyclotron current drive in KSTAR plasmas

Advanced operation scenarios such as high poloidal beta ( β P ) or high q min are promising concepts to achieve the steady-state high-performance fusion plasmas. However, those scenarios are prone to substantial Alfvénic activity, causing fast-ion transport and losses. Recent experiments with the advanced operation scenario on KSTAR tokamak have shown that the electron cyclotron current drive (ECCD) is able to mitigate and suppress the beam-ion driven toroidal Alfvén eigenmodes (TAEs) for over several tens of global energy confinement time. Co-current directional intermediate off-axis ECCD lowers the central safety factor slightly and tilts the central q -profile shape so that the continuum damping in the core region increases. Besides, the rise of central plasma pressure and increased thermal-ion Landau damping contribute to TAE stabilization. While the TAEs are suppressed, neutron emission rate and total stored energy increase by approximately 45% and 25%, respectively. Fast-ion transport estimated by TRANSP calculations approaches the classical level during the TAE suppression period. Substantial reduction in fast-ion loss and neutron deficit is also observed. Subsequently, enhancement of fast-ion confinement by suppressing the TAEs leads to an increase of non-inductive current fraction and will benefit the sustainment of the long-pulse high-performance discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of motional Stark effect in situ background correction to a superconducting tokamak

A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.

47 OTHER INSTRUMENTATION↗