SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗

An Inrush Current Limit Method for SiC-based Multi-level Grid-connected Converter During Low-Voltage Ride-Through

Low-voltage ride-through is one of the grid requirements for grid-connected converters, and during the transient of grid voltage change, a large inrush current could be induced due to the control delay of the converter. This inrush current is more severe in SiC-based multi-level converters due to the small filter inductance, which is selected based on harmonics consideration. In this paper, a PWM mask method is used to limit the inrush current of a cascaded H-bridge-based grid-connected converter during the transient of grid voltage change. Simulation and experiment results are provided to validate this method.

Li, Haiguo↗

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic in Dual-Active-Bridge Converters

The Dual-Active-Bridge (DAB) converter transformer flux unbalance, or dc bias, could be a critical issue due to the mismatches of converter circuit parameters and control transients. In this paper, a steady-state flux balancing scheme, based on the second-order harmonic of magnetizing current has been proposed. The relationship between steady-state flux/magnetizing current unbalance and its harmonic contents has been analyzed, with which a new current sensing method and control strategy are introduced. The proposed magnetizing current sensing method can be implemented for both unity and complicated fractional turns ratios, without high sensitivity to dc offset from the analog circuitry. The proposed scheme has been validated with experimental results on 850-V/850-V DAB converters within a system, as well as in an 850-V/6700-V medium voltage DAB unit.

Gao, Zihan↗

Benefits of high-voltage SiC-based power electronics in medium-voltage power-distribution grids

Medium-voltage (MV) power electronics equipment has been increasingly applied in distribution grids, and high-voltage (HV) silicon carbide (SiC) power semiconductors have attracted considerable attention in recent years. This paper first overviews the development and status of HV SiC power semiconductors. Then, MV power-converter applications in distribution grids are summarized and the benefits of HV SiC in these applications are presented. Microgrids, including conventional and asynchronous microgrids, that can fully demonstrate the benefits of HV SiC power semiconductors are selected to investigate the benefits of HV SiC in detail, including converter-level benefits and system-level benefits. Finally, an asynchronous microgrid power-conditioning system (PCS) prototype using a 10 kV SiC MOSFET is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular Multilevel Converter (MMC) Modeling Considering Submodule Voltage Sensor Noise

The modular multilevel converter (MMC) is a popular topology in medium- and high-voltage applications, and many efforts have been spent on MMC modeling. However, the impact of submodule voltage sensor noise (SVSN), which becomes more severe due to increasing switching speed of power semiconductors and compact submodule design, has not been considered in conventional models. In this letter, the SVSN is introduced by coupling capacitances between the sensor and power stage in an MMC switching model. Furthermore, the SVSN impact is considered in an MMC average model based on derivation of the relationship between the SVSN and the duty cycle. Here, the proposed MMC switching model and average model considering the SVSN are validated by comparing simulations with experimental results in an MMC prototype using 10-kV SiC MOSFETS.

47 OTHER INSTRUMENTATION↗

Design Considerations for High-Voltage Insulated Gate Drive Power Supply for 10-kV SiC MOSFET Applied in Medium-Voltage Converter

High-performance gate drive power supply (GDPS) plays a crucial role in ensuring the reliability and safety of the gate driver for power semiconductor devices. This article focuses on the design of a high-voltage-insulated GDPS for the 10-kV silicon carbide MOSFET in medium-voltage (MV) application. Design considerations, including insulation scheme, high-voltage-insulated transformer design, and load voltage regulation scheme, are proposed. In addition, the performance of the secondary-side-regulated (SSR) GDPS and that of the primary-side-regulated (PSR) GDPS are compared for several aspects, including interwinding capacitance, load voltage regulation rate, conversion efficiency, and hardware complexity. Finally, an SSR GDPS and a PSR GDPS, with an insulation voltage of 20 kV, are built in the lab. Furthermore, the test results demonstrate that the PSR GDPS is more preferable because of lower interwinding capacitance, lower load voltage regulation rate, higher conversion efficiency, and simpler control circuit.

42 ENGINEERING↗

A Novel Voltage Balancing Control With dv/dt Reduction for 10-kV SiC MOSFET-Based Medium Voltage Modular Multilevel Converter

Using high voltage (HV) silicon carbide (SiC) power semiconductors in a modular multilevel converter (MMC) is promising because it results in fewer submodules and lower switching loss compared to conventional Si based solutions. The nearest level pulsewidth modulation (NL-PWM) is commonly used in the MMC for medium voltage applications. However, with the NL-PWM and existing voltage balancing control, there are many submodules that switch their modes in a control cycle, resulting in a high dv/dt during the deadtime of the power semiconductor, which could be multiple times of the dv/dt of the single device. This poses great challenges on the noise immunity and insulation design in the MMC using HV SiC devices, which have very fast switching speed. A novel voltage balancing control, which ensures only two submodules switch their modes in a control cycle, is proposed in this article, limiting the maximum dv/dt to the dv/dt of a single power semiconductor and also maintaining the voltage balance performance. Furthermore, the proposed voltage balancing control is experimentally validated in a 10-kV SiC mosfet based MMC with four submodules per arm.

42 ENGINEERING↗

Flux Balancing Control of Ungapped Nanocrystalline Core-Based Transformer in Dual Active Bridge Converters

Transformer flux dc bias is a critical issue, impacting the reliable operation of dual active bridge (DAB) converters especially when ungapped high permeability nanocrystalline core is used. Steady state current dc bias can easily saturate ungapped nanocrystalline transformers, and it is even more dangerous in transient conditions. A dc bias model is proposed to analyze steady state dc bias in different load conditions. The magnetizing current detection is necessary for closed-loop control of dc bias; conductors' position is shown to impact sensor noise, and it is analyzed in detail. To deal with both steady state and transient dc bias, a unified flux balancing control (UFBC) is proposed introducing a predictive bias suppression (PBS) method with closed-loop flux balancing control (CFBC). With the proposed PBS, both primary/secondary current balance and flux balance can be achieved within one switching cycle using UFBC. Power characteristics and interaction between power control and flux balancing control of DAB converters are analyzed, and the CFBC needs to work in a low bandwidth due to sensor bandwidth limitation and interaction between power control and flux balancing control. Lastly, the UFBC is verified on a 300-kW cascaded DAB converter prototype.

42 ENGINEERING↗

Medium Voltage (13.8 kV) Transformer-less Grid-Connected DC/AC Converter Design and Demonstration Using 10 kV SiC MOSFETs

Medium voltage (MV) power converters using high voltage (HV) Silicon Carbide (SiC) power semiconductors result in great benefits in weight, size, efficiency and control bandwidth. However, challenges still exist on the components design considering HV insulation and noise immunity requirements in the MV SiC based power converter. A 5-level MMC based transformer-less grid-connected dc/ac converter is developed for 13.8 kV medium voltage grid using 10 kV SiC MOSFETs. The key components, including gate driver with high dv/dt immunity and fast reliable protection, isolated power supply with low parasitic capacitance, voltage/current sensors with high noise immunity, and passives following related insulation standard are provided. A 25 kV dc-link phase-leg is demonstrated, and the experimental results are presented.

Ji, Shiqi↗

Parasitic Capacitors' Impact on Switching Performance in a 10 kV SiC MOSFET Based Converter

In a converter based on 10 kV SiC MOSFETs, major sources of parasitic capacitance are the anti-parallel junction barrier schottky (JBS) diode, heat sink, and load inductor. A half bridge phase leg test setup is built to investigate these parasitic capacitors’ impact on the switching performance at 6.25 kV. Generally these parasitic capacitors slows down both turn-on and turn-off transient and can cause significant increase in switching energy loss. The impact of the parasitic capacitor in the load inductor is analyzed, which has either very short wire or long wire in series. Switching performance of the phase leg with two different thermal designs are compared to investigate the impact of the parasitic capacitor due to the heat sink. The large parasitic capacitor due to the large drain plate of discrete 10 kV SiC MOSFET for heat dissipation can result in 44.5% increase in switching energy loss at low load current.

Huang, Xingxuan↗

An FPGA-Based Voltage Balancing Control for Multi-HV-IGBTs in Series Connection

The series connection of insulated gate bipolar transistors (IGBTs) allows operation at voltage levels higher than the rated voltage of one IGBT and has less power semiconductor costs compared to multilevel topologies. However, voltage unbalance during the switching transient is a challenge for series-connected device application. This paper presents an field-programmable gate array (FPGA)-based voltage balancing strategy for multiseries-connected high-voltage (HV)-IGBTs including an FPGA-based active voltage balancing control (AVBC) circuit integrated into the gate driver and the control for multiseries-connected IGBTs. As a result, the effectiveness of the control has been experimentally validated in a prototype using four 4.5 kV HV-IGBTs in series connection.

42 ENGINEERING↗

Short-Circuit Characterization and Protection of 10-kV SiC mosfet

This paper presents the characterization of the temperature-dependent short-circuit performance of a Gen3 10 kV/20 A silicon carbide (SiC) mosfet. The test platform consisting of a phase-leg configuration and a fast speed 10-kV solid state circuit breaker, with temperature control, is introduced in detail. A novel FPGA-based short-circuit protection circuit having a response time of 1.5 μs is proposed and integrated into the gate driver. The short-circuit protection is validated through the platform. The short-circuit characteristics for both the hard switching fault and fault under load (FUL) types at various dc-link voltages (from 500 V to 6 kV) are tested and discussed. The saturation current increases with dc-link voltage and achieves 360 A at 6 kV. Different from low voltage SiC devices, there is no current spike in FUL type of fault. The temperature-dependent short-circuit performance is also presented from 25 to 125 °C. The difference of short-circuit waveforms at various initial junction temperatures can be neglected. Here, a thermal model of the 10-kV SiC mosfet is built for the junction temperature estimation during the short circuit and for analysis of the initial junction temperature impact on the short-circuit performance.

10-kV SiC mosfet↗

Short circuit characterization of 3rdgeneration 10 kV SiC MOSFET

The short circuit performance of a 3 rd generation 10 kV/20 A SiC MOSFET with short channel is characterized in this paper. The platform consisting of a phase-leg configuration, which can test both hard switching fault (HSF) and fault under load (FUL) types of fault, is introduced in detail. A Si IGBT based solid state circuit breaker is developed for short circuit test. The short circuit protection having a response time of 1.5 μs is validated by the test platform. The short circuit characteristics for both the HSF and FUL types at 6 kV DC-link are presented and analyzed.

Ji, Shiqi↗

Temperature-Dependent Characterization, Modeling, and Switching Speed-Limitation Analysis of Third-Generation 10-kV SiC MOSFET

The temperature-dependent characteristics of the third-generation 10-kV/20-A SiC MOSFET including the static characteristics and switching performance are carried out in this paper. The steady-state characteristics, including saturation current, output characteristics, antiparallel diode, and parasitic capacitance, are tested. Here, a double pulse test platform is constructed including a circuit breaker and gate drive with >10-kV insulation and also a hotplate under the device under test for temperature-dependent characterization during switching transients. The switching performance is tested under various load currents and gate resistances at a 7-kV dc-link voltage from 25 to 125 C and compared with previous 10-kV MOSFETs. A simple behavioral model with its parameter extraction method is proposed to predict the temperature-dependent characteristics of the 10-kV SiC MOSFET. The switching speed limitations, including the reverse recovery of SiC MOSFET's body diode, overvoltage caused by stray inductance, crosstalk, heat sink, and electromagnetic interference to the control are discussed based on simulations and experimental results.

10-kV silicon carbide (SiC) metal–oxide–semiconduc↗