Search NASA⌕ Search

Engineering topics

Jiang, D.

Publications and source records attributed to Jiang, D..

Temperature-dependence of superelastic stress in nanocrystalline NiTi with complete transformation capability

Nanocrystalline (NC) NiTi were previously reported to obtain non-hysteretic superelasticity and nearly zero temperature-dependence of superelastic stresses. However, the influence of the non-transforming regions in the specimens was not ruled out. In this study, we fabricate NC NiTi specimens with grain size down to 15 nm by wire drawing and annealing. Our specimens have no detectable non-transforming regions and thus are of complete transformation capability. We demonstrate that the hysteretic superelasticity is observed in all specimens of different grain sizes and that the minimum temperature-dependence of superelastic stresses is 4.7 MPa/K. Possible reasons for the discrepancy have been discussed.

36 MATERIALS SCIENCE↗

First measurement of the edge charge exchange recombination spectroscopy on EAST tokamak

An edge toroidal charge exchange recombination spectroscopy (eCXRS) diagnostic, based on a heating neutral beam injection (NBI), has been deployed recently on the Experimental Advanced Superconducting Tokamak (EAST). The eCXRS, which aims to measure the plasma ion temperature and toroidal rotation velocity in the edge region simultaneously, is a complement to the exiting core CXRS (cCXRS). Two rows with 32 fiber channels each cover a radial range from ∼2.15 m to ∼2.32 m with a high spatial resolution of ∼5-7 mm. Charge exchange emission of Carbon VI CVI at 529.059 nm induced by the NBI is routinely observed, but can be tuned to any interested wavelength in the spectral range from 400 to 700 nm. Double-slit fiber bundles increase the number of channels, the fibers viewing the same radial position are binned on the CCD detector to improve the signal-to-noise ratio, enabling shorter exposure time down to 5 ms. One channel is connected to a neon lamp, which provides the real-time wavelength calibration on a shot-to-shot basis. In this paper, an overview of the eCXRS diagnostic on EAST is presented and the first results from the 2015 experimental campaign will be shown. Good agreements in ion temperature and toroidal rotation are obtained between the eCXRS and cCXRS systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved spatial calibration for the CXRS system on EAST

A Charge eXchange Recombination Spectroscopy (CXRS) diagnostic system has been developed to measure profiles of ion temperature and rotation since 2014 on EAST. Several techniques have been developed to improve the spatial calibration of the CXRS diagnostic. The sightline location was obtained by measuring the coordinates of three points on each sightline using an articulated flexible coordinate measuring arm when the vessel was accessible. After vacuum pumping, the effect of pressure change in the vacuum vessel was evaluated by observing the movement of the light spot from back-illuminated sightlines on the first wall using the newly developed articulated inspection arm. In addition, the rotation of the periscope after vacuum pumping was derived by using the Doppler shift of neutral beam emission spectra without magnetic field. Combining these techniques, improved spatial calibration was implemented to provide a complete and accurate description of the EAST CXRS system. Due to the effects of the change of air pressure, a ∼0.4° periscope rotation, yielding a ∼20 mm movement of the major radius of observation positions to the lower field side, was derived. Results of Zeeman splitting of neutral beam emission spectra with magnetic field also showed good agreement with the calibration results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗