Search NASA⌕ Search

Engineering topics

Jiang, L

Publications and source records attributed to Jiang, L.

At least 19 records

Convolutional Neural Networks Applied to Neutrino Events in a Liquid Argon Time Projection Chamber

We present several studies of convolutional neural networks applied to data coming from the MicroBooNE detector, a liquid argon time projection chamber (LArTPC). The algorithms studied include the classification of single particle images, the localization of single particle and neutrino interactions in an image, and the detection of a simulated neutrino event overlaid with cosmic ray backgrounds taken from real detector data. These studies demonstrate the potential of convolutional neural networks for particle identifi-cation or event detection on simulated neutrino interactions. We also address technical issues that arise when applying this technique to data from a large LArTPC at or near ground level.

Acciarri, R↗

WE-D-9A-01: A Novel Mesh-Based Deformable Surface-Contour Registration

Purpose: Initial guess is vital for 3D-2D deformable image registration (DIR) while dealing with large deformations for adaptive radiation therapy. A fast procedure has been developed to deform body surface to match 2D body contour on projections. This surface-contour DIR will provide an initial deformation for further complete 3D DIR or image reconstruction. Methods: Both planning CT images and come-beam CT (CBCT) projections are preprocessed to create 0–1 binary mask. Then the body surface and CBCT projection body contours are extracted by Canny edge detector. A finite element modeling system was developed to automatically generate adaptive meshes based on the image surface. After that, the projections of the CT surface voxels are computed and compared with corresponding 2D projection contours from CBCT scans. As a result, the displacement vector field (DVF) on mesh vertices around the surface was optimized iteratively until the shortest Euclidean distance between the pixels on the projections of the deformed CT surface and the corresponding CBCT projection contour is minimized. With the help of the tetrahedral meshes, we can smoothly diffuse the deformation from the surface into the interior of the volume. Finally, the deformed CT images are obtained by the optimal DVF applied on the original planning CT images. Results: The accuracy of the surface-contour registration is evaluated by 3D normalized cross correlation increased from 0.9176 to 0.9957 (sphere-ellipsoid phantom) and from 0.7627 to 0.7919 (H and N cancer patient data). Under the GPU-based implementation, our surface-contour-guided method on H and N cancer patient data takes 8 seconds/iteration, about 7.5 times faster than direct 3D method (60 seconds/iteration), and it needs fewer optimization iterations (30 iterations vs 50 iterations). Conclusion: The proposed surface-contour DIR method can substantially improve both the accuracy and the speed of reconstructing volumetric images, which is helpful for applying in adaptive radiotherapy. This research is supported by CPRIT individual investigator award RP110329.

60 APPLIED LIFE SCIENCES↗

WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration

Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints in the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-J-23: An Accurate Algorithm to Match Imperfectly Matched Images for Lung Tumor Detection Without Markers

Purpose: In order to locate lung tumors on projection images without internal markers, digitally reconstructed radiograph (DRR) is created and compared with projection images. Since lung tumors always move and their locations change on projection images while they are static on DRRs, a special DRR (background DRR) is generated based on modified anatomy from which lung tumors are removed. In addition, global discrepancies exist between DRRs and projections due to their different image originations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported. Methods: This method divides global images into a matrix of small tiles and similarities will be evaluated by calculating normalized cross correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) will be automatically optimized to keep the tumor within a single tile which has bad matching with the corresponding DRR tile. A pixel based linear transformation will be determined by linear interpolations of tile transformation results obtained during tile matching. The DRR will be transformed to the projection image level and subtracted from it. The resulting subtracted image now contains only the tumor. A DRR of the tumor is registered to the subtracted image to locate the tumor. Results: This method has been successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (Brainlab) for dynamic tumor tracking on phantom studies. Radiation opaque markers are implanted and used as ground truth for tumor positions. Although, other organs and bony structures introduce strong signals superimposed on tumors at some angles, this method accurately locates tumors on every projection over 12 gantry angles. The maximum error is less than 2.6 mm while the total average error is 1.0 mm. Conclusion: This algorithm is capable of detecting tumor without markers despite strong background signals.

60 APPLIED LIFE SCIENCES↗

The Structural Basis for Tight Control of PP2A Methylation and Function by LCMT-1

Proper formation of protein phosphatase 2A (PP2A) holoenzymes is essential for the fitness of all eukaryotic cells. Carboxyl methylation of the PP2A catalytic subunit plays a critical role in regulating holoenzyme assembly; methylation is catalyzed by PP2A-specific methyltransferase LCMT-1, an enzyme required for cell survival. We determined crystal structures of human LCMT-1 in isolation and in complex with PP2A stabilized by a cofactor mimic. The structures show that the LCMT-1 active-site pocket recognizes the carboxyl terminus of PP2A, and, interestingly, the PP2A active site makes extensive contacts to LCMT-1. We demonstrated that activation of the PP2A active site stimulates methylation, suggesting a mechanism for efficient conversion of activated PP2A into substrate-specific holoenzymes, thus minimizing unregulated phosphatase activity or formation of inactive holoenzymes. A dominant-negative LCMT-1 mutant attenuates the cell cycle without causing cell death, likely by inhibiting uncontrolled phosphatase activity. Our studies suggested mechanisms of LCMT-1 in tight control of PP2A function, important for the cell cycle and cell survival.

59 BASIC BIOLOGICAL SCIENCES↗

VERY EARLY ULTRAVIOLET AND OPTICAL OBSERVATIONS OF THE TYPE Ia SUPERNOVA 2009ig

Supernova (SN) 2009ig was discovered 17 hr after explosion by the Lick Observatory Supernova Search, promptly classified as a normal Type Ia SN (SN Ia), peaked at V = 13.5 mag, and was equatorial, making it one of the foremost SNe for intensive study in the last decade. Here, we present ultraviolet (UV) and optical observations of SN 2009ig, starting about 1 day after explosion until around maximum brightness. Our data include excellent UV and optical light curves, 25 premaximum optical spectra, and 8 UV spectra, including the earliest UV spectrum ever obtained of an SN Ia. SN 2009ig is a relatively normal SN Ia, but does display high-velocity ejecta-the ejecta velocity measured in our earliest spectra (v Almost-Equal-To -23, 000 km s{sup -1} for Si II {lambda}6355) is the highest yet measured in an SN Ia. The spectral evolution is very dramatic at times earlier than 12 days before maximum brightness, but slows after that time. The early-time data provide a precise measurement of 17.13 {+-} 0.07 days for the SN rise time. The optical color curves and early-time spectra are significantly different from template light curves and spectra used for light-curve fitting and K-corrections, indicating that the template light curves and spectra do not properly represent all SNe Ia at very early times. In the age of wide-angle sky surveys, SNe like SN 2009ig that are nearby, bright, well positioned, and promptly discovered will still be rare. As shown with SN 2009ig, detailed studies of single events can provide significantly more information for testing systematic uncertainties related to SN Ia distance estimates and constraining progenitor and explosion models than large samples of more distant SNe.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE FOR NON-EVOLVING Fe II/Mg II RATIOS IN RAPIDLY ACCRETING z {approx} 6 QSOs

Quasars (QSOs) at the highest known redshift (z {approx} 6) are unique probes of the early growth of supermassive black holes (BHs). Until now, only the most luminous QSOs have been studied, often one object at a time. Here we present the most extensive consistent analysis to date of 4 < z < 6.5 QSOs with observed near-infrared spectra, combining three new z {approx} 6 objects from our ongoing Very Large Telescope-Infrared Spectrometer And Array Camera program with nineteen sources from the literature. The new sources extend the existing Sloan Digital Sky Survey (SDSS) sample toward the faint end of the QSO luminosity function. Using a maximum likelihood fitting routine optimized for our spectral decomposition, we estimate the BH mass (M{sub BH}), the Eddington ratio (defined as L{sub bol}/L{sub Edd}), and the Fe II/Mg II line ratio, a proxy for the chemical abundance, to characterize both the central object and the broad-line region gas. The QSOs in our sample host BHs with masses of {approx}10{sup 9} M{sub sun} that are accreting close to the Eddington luminosity, consistent with earlier results. We find that the distribution of observed Eddington ratios is significantly different than that of a luminosity-matched comparison sample of SDSS QSOs at lower redshift (0.35 < z < 2.25): the average (log (L{sub bol}/L{sub Edd})) = -0.37 (L{sub bol}/L{sub Edd} {approx} 0.43) with a scatter of 0.20 dex for the z > 4 sample and the (log (L{sub bol}/L{sub Edd})) = -0.80 (L{sub bol}/L{sub Edd} {approx} 0.16) with a scatter of 0.24 dex for the 0.35 < z < 2.25 sample. This implies that, at a given luminosity, the M{sub BH} at high-z is typically lower than the average M{sub BH} of the lower-redshift population, i.e., the z > 4 sources are accreting significantly faster than the lower-redshift ones. We show that the derived Fe II/Mg II ratios depend sensitively on the analysis performed: our self-consistent, homogeneous analysis significantly reduces the Fe II/Mg II scatter found in previous studies. The measured Fe II/Mg II line ratios show no sign of evolution with cosmic time in the redshift range 4 < z < 6.5. If the Fe II/Mg II line ratio is used as a secondary proxy of the Fe/Mg abundance ratio, this implies that the QSOs in our sample have undergone a major episode of Fe enrichment in the few 100 Myr preceding the cosmic age at which they are observed.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Accumulative Roll Bonding on Plastic Flow Properties of Commercially Pure Zirconium

Accumulative roll bonding (ARB) has been considered as one of the promising techniques for fabrication of ultra-fine grained (UFG) metallic materials. The ARB process consists of several cycles of cutting, stacking, and rolling of metal sheets, so very high strains can be induced in the material resulting in significant grain refinement and in the formation of UFG microstructures. The ARB technique has been applied to a wide range of metallic materials such as Al and Al alloys, Mg, Fe and steels, Zr, Cu, as well as composite materials. UFG metallic materials processed via ARB show increased strength. Despite a significant body of experimental research into the deformation behaviour of the ARB-processed materials, the fundamentals of their plastic deformation are not fully understood yet. This work focuses on the effect of grain refinement via ARB-processing on the mechanical behavior and on the strain-rate sensitivity of commercially pure Zr (99.8% purity). The mechanical properties of the as-received coarse-grained (CG) and UFG (as-ARB processed) samples were studied at room temperature at two different strain rates. Mechanical strain rate jump tests were performed during tensile deformation to estimate the instantaneous strain-rate sensitivity. The evolution of surface relief during plastic deformation of pure Zr in both CG and UFG conditions was studied. The features of plastic deformation of pure Zr in both CG and UFG conditions are discussed.

36 MATERIALS SCIENCE↗

New Measurement of the {pi}{sup 0} Radiative Decay Width

High precision measurements of the differential cross sections for {pi}{sup 0} photoproduction at forward angles for two nuclei, {sup 12}C and {sup 208}Pb, have been performed for incident photon energies of 4.9-5.5 GeV to extract the {pi}{sup 0}{yields}{gamma}{gamma} decay width. The experiment was done at Jefferson Lab using the Hall B photon tagger and a high-resolution multichannel calorimeter. The {pi}{sup 0}{yields}{gamma}{gamma} decay width was extracted by fitting the measured cross sections using recently updated theoretical models for the process. The resulting value for the decay width is {Gamma}({pi}{sup 0}{yields}{gamma}{gamma})=7.82{+-}0.14(stat){+-}0.17(syst) eV. With the 2.8% total uncertainty, this result is a factor of 2.5 more precise than the current Particle Data Group average of this fundamental quantity, and it is consistent with current theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Environment-Assisted Precision Measurement

We describe a method to enhance the sensitivity of precision measurements that takes advantage of the environment of a quantum sensor to amplify the response of the sensor to weak external perturbations. An individual qubit is used to sense the dynamics of surrounding ancillary qubits, which are in turn affected by the external field to be measured. The resulting sensitivity enhancement is determined by the number of ancillas that are coupled strongly to the sensor qubit; it does not depend on the exact values of the coupling strengths and is resilient to many forms of decoherence. The method achieves nearly Heisenberg-limited precision measurement, using a novel class of entangled states. We discuss specific applications to improve clock sensitivity using trapped ions and magnetic sensing based on electronic spins in diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast growth of graphene patterns by laser direct writing

Rapid single-step fabrication of graphene patterns was developed using laser-induced chemical vapor deposition (LCVD). A laser beam irradiates a thin nickel foil in a CH{sub 4} and H{sub 2} environment to induce a local temperature rise, thereby allowing the direct writing of graphene patterns in precisely controlled positions at room temperature. Line patterns can be achieved with a single scan without pre- or postprocesses. Surprisingly, the growth rate is several thousand times faster than that of general CVD methods. The discovery and development of the LCVD growth process provide a route for the rapid fabrication of graphene patterns for various applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

IONIZATION NEAR ZONES ASSOCIATED WITH QUASARS AT z {approx} 6

We analyze the size evolution of H II regions around 27 quasars between z = 5.7 and 6.4 ('quasar near zones' or NZs). We include more sources than previous studies, and we use more accurate redshifts for the host galaxies, with eight CO molecular line redshifts and nine Mg II redshifts. We confirm the trend for an increase in NZ size with decreasing redshift, with the luminosity-normalized proper size evolving as R{sub NZ,corrected} = (7.4 {+-} 0.3) - (8.0 {+-} 1.1) x (z - 6) Mpc. While derivation of the absolute neutral fraction remains difficult with this technique, the evolution of the NZ sizes suggests a decrease in the neutral fraction of intergalactic hydrogen by a factor {approx}9.4 from z = 6.4 to 5.7, in its simplest interpretation. Alternatively, recent numerical simulations suggest that this rapid increase in NZ size from z = 6.4 to 5.7 is due to the rapid increase in the background photo-ionization rate at the end of the percolation or overlap phase, when the average mean-free path of ionizing photons increases dramatically. In either case, the results are consistent with the idea that z {approx} 6-7 corresponds to the tail end of cosmic reionization. The scatter in the normalized NZ sizes is larger than expected simply from measurement errors, and likely reflects intrinsic differences in the quasars or their environments. We find that the NZ sizes increase with quasar UV luminosity, as expected for photo-ionization dominated by quasar radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast entanglement distribution with atomic ensembles and fluorescent detection

Quantum repeaters based on atomic ensemble quantum memories are promising candidates for achieving scalable distribution of entanglement over long distances. Recently, important experimental progress has been made toward their implementation. However, the entanglement rates and scalability of current approaches are limited by relatively low retrieval and single-photon detector efficiencies. We propose a scheme which makes use of fluorescent detection of stored excitations to significantly increase the efficiency of connection and hence the rate. Practical performance and possible experimental realizations of the new protocol are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NEAR-INFRARED SPECTROSCOPY OF SDSS J0303 - 0019: A LOW-LUMINOSITY, HIGH-EDDINGTON-RATIO QUASAR AT z {approx} 6

We present sensitive near-infrared (NIR) VLT ISAAC spectroscopic observations of the z = 6.08 quasar SDSS J030331.40-001912.9. This quasi-stellar object (QSO) is more than a magnitude fainter than other QSOs at z {approx} 6 for which NIR spectroscopy has been obtained to date and is therefore presumably more representative of the QSO population at the end of cosmic reionization. Combining rest-frame UV continuum luminosity with the width measurements of the Mg II and C IV lines, we derive a black hole mass of 2{sup +1.0} {sub -0.5} x 10{sup 8} M {sub sun}, the lowest mass observed for z {approx} 6 QSOs to date, and derive an Eddington ratio of 1.6{sup +0.4} {sub -0.6}, among the highest value derived for QSOs at any redshift. The Spitzer 24 {mu}m nondetection of this QSO does not leave space for a significant hot dust component in its optical/NIR spectral energy distribution, in common with one other faint QSO at z = 6, but in contrast to more than 20 more z = 6 QSOs and all known lower redshift QSOs with sufficiently deep multiwavelength photometry. We conclude that we have found evidence for differences in the intrinsic properties of at least one z {approx} 6 QSO as compared to the lower redshift population.

79 ASTRONOMY AND ASTROPHYSICS↗