Search NASA⌕ Search

Engineering topics

Jo, Y.

Publications and source records attributed to Jo, Y..

Reactivity initiated accident uncertainty quantification for fuel assembly with subchannel code

UNIST CORE lab has developed a multiphysics coupling framework (MPCORE) consisting of Neutronics, Thermal Hydraulics and Fuel Performance modules. It can accommodate one-dimensional as well as sub-channel code Thermal Hydraulics (TH) module. Generally, running a transient requires more computational power due to the convergence of modules with each other. The difference between one-dimensional and sub-channel TH modules is studied in this research for a Reactivity Initiated Accident (RIA). Both TH modules are compared for a RIA uncertainty propagation in a single VERA fuel assembly with 2.11% enrichment. MPCORE is capable of analyzing the transient at any burnup point but for current work, only fresh fuel has been considered. The results have been obtained using dynamic gap heat conductance in FRAPTRAN. Peak centerline temperature, fuel enthalpy and DNBR are compared for both the approaches. The results indicate that the use of sub-channel code lead to greater safety margin for critical parameters. Computation time comparison is also presented for both the cases. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calculation of neutron flux spectra of the VVER-1000 mock-up shielding benchmark with Monte Carlo code MCS utilizing mesh-based weight window

The measurements of neutron spectra compiled inside the NEA-1517/82 package from the Shielding Integral Benchmark Archive and Database (SINBAD) are chosen as benchmark cases to validate the variance reduction technique based on weight window in Monte Carlo Code MCS. A full 3D model for fixed source mode calculation with hexagonal lattice source definition is developed to simulate total of 6 points of measurements at the vicinity of the reactor and the reactor pressure vessel region. A code/code comparison against MCNP6 code is first conducted as verification element for the mesh-based weight window capability in MCS. Finally, the validation results are presented against measurements. The verification against MCNP6 code gives good agreement in addition of the insight to the importance of user understanding to determine proper reference point and reference lower weight bound for scaling which is not required in MCS code due to its capability of automatic scaling. The comparison of neutron spectra between MCS and measurements shows good agreement within 3 standard deviations for all of six detector positions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗