Search NASA⌕ Search

Engineering topics

Job, P K

Publications and source records attributed to Job, P K.

PROGRESS WITH NSLS-II INJECTION STRAIGHT SECTION DESIGN

The NSLS-II injection straight section (SR) consists of pulsed and DC bumps, septa system, beam trajectory correction and diagnostics systems. In this paper we discuss overall injection straight layout, preliminary element designs, specifications for the pulsed and DC magnets and their power supplies, vacuum devices and chambers and diagnostics devices. Prior to selecting the current 'conventional' design of the injection straight section we analyzed an option of injection via pulsed multipole pioneered at PF-AR. We found that this promising approach was not suited to the NSLS-II storage ring optics, since it would require a impractically compact arrangement of the injection straight section components and a complex modification of the transport line optics due to the strong focusing of the injected beam passing off the pulsed multipole axis. In addition, the requirement for a small injection transient of the stored beam orbit severely constrains the vertical alignment tolerance of the pulsed multipole. The design of the NSLS-II injection straight section is now completed with exception of transition chamber details, which will be adjusted to accommodate the actual layouts of the pulsed magnets.

43 PARTICLE ACCELERATORS↗

BEAM CONTAINMENT SYSTEM FOR NSLS-II

The shielding design for the NSLS-II will provide adequate protection for the full injected beam loss in two periods of the ring around the injection point, but the remainder of the ring is shielded for lower losses of {le} 10% full beam. This will require a system to insure that beam losses don't exceed these levels for a period of time that could cause excessive radiation levels outside the shield walls. This beam containment system will measure, provide a level of control and alarm indication of the beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators that will provide limits to (and potentially to measure) the beam miss-steering and control the loss points of the charge and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications. This will require some new ideas in beam loss detection capability and collimation. The initial planning and R&D program will be presented.

43 PARTICLE ACCELERATORS↗

An Experimental Study of Radiation-Induced Demagnetization of Insertion Device Permanent Magnets

High brilliance in the 3GeV new light source NSLS II is obtained from the high magnetic fields in insertion devices (ID). The beam lifetime is limited to 3h by single Coulomb scattering in the Bunch (Touschek effect). This effect occurs everywhere around the circumference and there is unavoidable beam loss in the adjacent low aperture insertion devices. This raises the issue of degradation and damage of the permanent magnetic material by irradiation with high energy electrons and corresponding shower particles. It is expected that IDs, especially those in-vacuum, would experience changes resulting from exposure to gamma rays, x-rays, electrons and neutrons. By expanding an on-going material radiation damage study at BNL the demagnetization effect of irradiation consisting primarily of neutrons, gamma rays and electrons on a set of NdFeB magnets is studied. Integrated doses ranging from several Mrad to a few Grad were achieved at the BNL Isotope Facility with a 112 MeV, 90 {micro}A proton beam. Detailed information on dose distributions as well as on particle energy spectra on the NdFeB magnets was obtained in realistic simulations with the MARS15 Monte-Carlo code. This paper summarizes the results of this study.

43 PARTICLE ACCELERATORS↗

Shielding Calculations for NSLS-II Beamlines.

Brookhaven National Laboratory is in the process of designing a new Electron Synchrotron for scientific research using synchrotron radiation. This facility, called the 'National Synchrotron Light Source II' (NSLS-II), will provide x-ray radiation of ultra-high brightness and exceptional spatial and energy resolution. It will also provide advanced insertion devices, optics, detectors, and robotics, and a suite of scientific instruments designed to maximize the scientific output of the facility. The project scope includes the design, construction, installation, and commissioning of the following accelerators: a 200 MeV linac, a booster accelerator operating from 200 MeV to 3.0 GeV, the storage ring which stores 500 mA current of electrons at an energy of 3.0 GeV and 56 beamlines for experiments. It is planned to operate the facility primarily in a top-off mode, thereby maintaining the maximum variation in stored beam current to < 1%. Because of the very demanding requirements for beam emittance and synchrotron radiation brilliance, the beam life-time is expected to be quite low, on the order of 2 hours. Each of the 56 beamlines will be unique in terms of the source properties and configuration. The shielding designs for five representative beamlines are discussed in this paper.

43 PARTICLE ACCELERATORS↗