Comparison of Analytical Shielding Calculations for NSLS-II Linac Lateral Wall with FLUKA Monte-Carlo Program

The bulk shielding for NSLS II accelerator enclosures has been designed to reduce the dose rates to less than 0.5 mrem/h at the occupied regions during normal operation. The lateral wall for Linac enclosure is designed to protect personnel from the transverse radiation. The current Linac lateral wall is composed of 1 m concrete, based on the analytical calculations using Swansons’ thick target approximation [1]. The dose rate calculations with current Linac lateral shielding (general area and penetrations) have been carried out by FLUKA. The FLUKA Monte Carlo results were compared with the analytical calculation [1]. The dose rates calculated by SHIELD11 [2] program for limited cases have also been included in this technical note.

36 MATERIALS SCIENCE↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference [1]. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year. This technical note presents the method used to identify these potential high beam loss locations, evaluate the potential radiation risk these losses create outside the enclosure shield and the design process that specifies the required local radiation shielding needed to reduce this risk below the maximum dose rate of the bulk shield design, listed above. If shielding can’t be adequately provided or if other fault initiated losses could occur, then the necessary engineering controls will be indicated that will limit the energy, current or duration of the beam transport that constitute this high beam loss risk.

36 MATERIALS SCIENCE↗

ALARA Review of NSLS-II Shielding Design

Radiation exposure to staff and users as the result of National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). The purpose of this document is to review the basis for the design choices used to limit radiation exposure at NSLS-II and demonstrate that the shielding and other radiological design features have been effectively and optimally integrated into the design of NSLS-II facilities.

36 MATERIALS SCIENCE↗

Preliminary Requirements for NSLS-II Beam Containment Systems

Beam containment system (BCS) is the term used to describe the various active and passive devices designed to prevent excessive radiation levels in occupied areas by limiting beam energy and beam losses. BCS components provide protection function by controlling machine operation through the NSLS-II personnel protective system (PPS) and through local and remote alarms. All equipment designated as a component of the BCS beam containment system will be subject to formal configuration control and, depending on the magnitude of the resulting radiation fields, may require redundant sensors and electronic channels.

36 MATERIALS SCIENCE↗

Radiological Considerations of Top-off Operation at NSLS-II

High current (500 mA) and low emittance (~1 nm) have been specified for NSLS-II to achieve ultra high brightness in a medium energy (3 GeV) storage ring (1) . This leads to the expectation that the lifetime in NSLS-II will be limited by Touschek scattering, and after commissioning will settle in at ~3 hours. It may well be less in the early days of operation. At the same time, the intensity stability specified by the user community is 1% or better.

36 MATERIALS SCIENCE↗

Preliminary Radiological Considerations for the Design and Operation of NSLS-II Storage Ring and Booster Synchrotron

Radiological conditions for the design and operation of NSLS II Storage Ring and Booster Synchrotron have been analyzed using the presently available design parameters. The Booster Synchrotron will be housed in the same tunnel as the Storage Ring at NSLS II. Calculations of the resulting radiation fields and required shielding have been made for normal stored beam loss and loss of beam during injection at the septum/extraction magnets.

36 MATERIALS SCIENCE↗

Preliminary Activation Analysis of Accelerator Components and Beam Stops at the NSLS-II

Bremsstrahlung is generated at the accelerator systems of the synchrotron radiation facilities by the radiative interaction of circulating electron beam with the accelerator components and with the residual gas molecules in the vacuum chamber. The photoneutron interaction of bremsstrahlung with the materials leads to the radio activation of the accelerator components through neutron emission and the production of radioisotopes. However this activation interaction is a second order effect because the intermediate process of bremsstrahlung production is involved. The photoneutron interaction takes place above the threshold bremsstrahlung energy of 7-20 MeV and the cross section for these interactions are in millibarns.

36 MATERIALS SCIENCE↗

Shadow Shields in the Storage Rings of NSLS-II

The bremsstrahlung source originating from beam losses in the storage ring of NSLS2 will be highly forward peaked along the tangents to the storage ring. The storage ring wall has a ratchet shape such that the ratchets facing the first optics enclosure of the beamlines will have the peak bremsstrahlung intensity due to beam losses incident perpendicular to the wall.

36 MATERIALS SCIENCE↗

An Online Beam Loss Monitor for NSLS-II Storage Ring

Reliable beam loss monitors are important tools for the safe operation of the accelerators. Beam loss monitors provide valuable information on the magnitude and location of the particle beam loss inside the accelerator enclosures. In the synchrotron radiation facilities, the electron accelerator enclosures experience a mixed radiation environment, consisting of low energy x-ray background along with bremsstrahlung and photoneutrons.

36 MATERIALS SCIENCE↗

Rachet Door Shielding Design Calculations

The ratchet wall at the experimental floor side will have sliding doors to provide access to beamline front ends during installation and maintenance. The thickness and design of these sliding doors should provide shielding equivalence of the concrete thickness of the ratchet wall. Each of the sliding doors will be a composite to provide effective shielding from neutron and gamma radiation, emanating from beam losses inside the storage ring.

36 MATERIALS SCIENCE↗

Design of the NSLS-II Top-Off Safety System

The NSLS-II accelerators finished commissioning in the fall of 2014, with beamline commissioning underway. Part of the design for the NSLS-II is to operate in top off mode. The Top Off Safety System (TOSS) is presently being installed. In this report we discuss the Top Off Safety System design and implementation, along with the necessary tracking results and radiological calculations.

43 PARTICLE ACCELERATORS↗

Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring

The primary radiological safety concern for the top-off injection, with the beam line front end safety shutters open, is the scenario where electrons could be conveyed down to the beam line through the front end due to the erroneous combination of lattice magnetic field settings and beam energy. It is of paramount importance to ensure that such events are of remote possibility. Particle tracking simulations by the NSLS-II Accelerator Physicists have shown that by a set of interlocking requirements of the lattice magnetic fields and by the implementation of physical apertures, the errant electron beam can be confined to the front end components within the storage ring.

36 MATERIALS SCIENCE↗

Comparison of Analytical Calculations for NSLS-II Booster Bulk Shielding with FLUKA Monte-Carlo Program

The dose rate calculations (normal operational beam loss) for the NSLS II 3.0 GeV booster ring bulk shielding like lateral wall and roof have been carried out by FLUKA. The FLUKA Monte Carlo results were compared with the prior analytical results based on thick target approximation [1]. The results showed that for most cases the analytical calculations are conservative compared with FLUKA for photon dose estimations. However the neutron dose from analytical calculations is lower than FLUKA for some cases because additional photon-neutron interactions in the shielding material are ignored in analytical calculations.

36 MATERIALS SCIENCE↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year.

36 MATERIALS SCIENCE↗

Supplementary Shielding Specifications for the NSLS-II Booster Enclosure

Bulk shielding at NSLS-II has been designed to reduce the ambient dose rates to < 5.0 μSv/h (0.5 mrem/h) at the exterior surface of the concrete shielding, during typical operation. This limits the maximum exposure to < 10 mSv/y (1,000 mrem/y) at the occupied areas, assuming 2,000 hours ofoccupancy per year.

36 MATERIALS SCIENCE↗

Supplementary Shielding Specifications for the NSLS-II Linac Enclosure

Bulk shielding at NSLS-II has been designed to reduce the ambient dose rates to < 5.0 μSv/h (0.5 mrem/h) at the exterior surface of the concrete shielding, during typical operation. This limits the maximum exposure to < 10 mSv/y (1,000 mrem/y) at the occupied areas, assuming 2,000 hours of occupancy per year.

36 MATERIALS SCIENCE↗

Effect of Vacuum Conditioning on the Bremsstrahlung Dose Rates at the NSLS-II Beamlines

Gas bremsstrahlung is produced by the interaction of the storage ring electron beam with residual gas molecules in the storage ring vacuum chamber. Such interactions are one of the sources of stored beam loss, result in beam decay, and occur continuously during the storage ring operation. Gas bremsstrahlung interactions take place all around the storage ring, but are a particular problem in the straight sections for the insertion devices. Bremsstrahlung produced as a narrow beam, sums up for the entire straight path in the line of sight of the insertion device beamlines and comes down through the beamlines along with the synchrotron radiation. The NSLS-II straight beam path in the line of sight for the insertion device beamlines is ~16 m in length. This poses a radiological safety issue at the beamlines.

36 MATERIALS SCIENCE↗