Water Quality Contamination Sources and Controls for the Exploration Extra-vehicular Mobility Unit (xEMU)

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. The xEMU uses controlled evaporative cooling through a membrane to reject waste heat from the crewmember, avionics, and environmental in-leak during autonomous operation. Given the unique mass and volume constraints imposed by the spacesuit application and the opportunities presented by the selection of a given membrane, the xEMU does not possess a separate feedwater loop to feed the evaporation process, rather the feedwater for the evaporation process is fed directly from the transport loop which collects heat from the sources within the suit. This has many benefits including mass/volume reductions from a lower component count within the system but does pose some additional potential constraints on water quality within the system in order to provide a working fluid that can be pumped, filtered, and used in contact with the remainder of the system while both avoiding fouling of the membrane as well as other deleterious effects such as creating conditions for corrosion of wetted surfaces within the transport loop. The discussion will seek to address the main sources of contamination and the applied controls. Sources considered will include: self-generated via materials selection and processes applied, influent working fluid, contamination of the influent working fluid via Ground Support Equipment (GSE) or processing equipment, microbial activity, and environmental influences such as elevated ambient CO2.

Colin Campbell↗

Early Results from a Broad Compatibility Study of Various Materials with Ionic Silver Biocide

Ionic silver is baselined for microbial control in spacecraft potable water systems forfuture exploration missions, but materials compatibility analysis is required to evaluate thepassive depletion of ionic silver concentration onto wetted material surfaces over time.Various articles concerning such testing have been published that examine interactions withwater containing ionic silver biocide, but most tests have focused on only a couple ofmaterials each and comparing results of different evaluations to one another has provedchallenging.This paper reports the first results from static exposure testing of a large arrayof material coupons to a 400 parts per billion (ppb) aqueous silver fluoride (AgF) solution,using a surface to volume ratio of approximately 2 cm-1. The test is designed in two mainstages. Stage 1 is a one-week screening to evaluate silver uptake. Materials that performmodestly to well after that week are promoted to Stage 2, which is a longer test with periodicsampling to examine the silver uptake rates over time; these samples are evaluated for otherwater quality parameters in addition to the remaining silver concentration. In a tangentialinvestigation, select materials that take up some silver in Stage 1 may be “aged” by repeatingthe Stage 1 test to determine whether repeated exposure reduces silver uptake rate, andsuccessfully aged materials may then continue to Stage 2 testing. The materials under testinclude metallic and polymeric materials with various surface finishes, treatments, andcoatings, as well as select other materials historically used in spacecraft water systems. Thistest began in August 2019, and thus only includes early results; future follow-on papers willinclude additional results as the test progresses. The ultimate goal builds a broad, easilycomparable data set that can be used to guide material selections for silver biocide-compatible spacecraft water system design.

Silver Biocide↗

Broad Compatibility Study of Polymeric Materials with Ionic Silver Biocide, Part I

NASA is considering ionic silver as a residual biocide for use in potable water systems being planned for future exploration spacecraft. Compatibility of the biocide with the system’s wetted-materials of construction remains a challenge. Due to the relatively inert nature of plastics, their use in varied water system applications may offer unique opportunities to address many biocide compatibility issues. A 2020 ICES paper described a “Stage 1” assessment of several polymeric materials, in which coupons having a 2 cm 1 surface to volume ratio were exposed to solutions of 400 parts per billion (ppb) aqueous silver fluoride (AgF) for one week. In this current paper, additional Stage 1 test results are presented for select epoxies and lubricants applied on silver-inert substrates. The coupon exposure studies were also expanded to a duration of 5 weeks for the “well-behaved” Stage 1 plastics previously reported: those exhibiting silver losses above 10% and less than 50%. For this type of Stage 2 testing, silver biocide solution samples are taken from three separate (and not previously-sampled) coupon containers after 3 days, and 2, 3, 4, and 5 weeks of exposure. "Very well-behaved" Stage 1 plastics will be tested in the same manner over one year, with longer sample intervals; early-period results are included here. In addition, for select materials, the coupons were “aged” by refilling test containers with fresh AgF and observing the respective silver uptake over similar Stage 2 test durations. For all test series, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and ion-selective electrode (ISE) analyses were used to determine total and ionic silver (Ag+) concentrations, respectively. Additional sample analyses for Stage 2 tests includes total organic carbon (TOC), pH, conductivity, and oxidation-reduction potential (ORP). Ultimately, these early compatibility studies will be used to guide future material selections for developing silver biocide-compatible spacecraft water systems.

Silver Biocide↗

SERFE Water Quality Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. Water quality, and how that impacts the performance of the life support system hardware, are areas where improvements could greatly help to achieve these goals. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. This paper will summarize the results of the water quality analysis performed to date throughout the SERFE testing program. Special care was taken to select materials, process hardware, and control the quality of the feedwater used in SERFE testing so that it would be representative of a thermal control system that could be used on a spacesuit for a lunar mission. In addition, the testing schedule, including periods of quiescence in between tests, was also selected to simulate a real mission profile in ways that would be critical to water quality. Results include data and analysis on microbial activity, biocidal iodine, metals, organic carbon, and several other customary indicators of water quality in an operational system. Testing spans over a year and a half of wetted life of the SERFE Flight Unit and the SERFE Ground Unit.

Colin Campbell↗