Search NASA⌕ Search

Engineering topics

Johns, Heather Marie

Publications and source records attributed to Johns, Heather Marie.

At least 19 records

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

FY2024 Q4 L2 Milestone 8237 for Opacity-on-NIF

This document addresses parts 2 and 3 of the original milestone request. In the following writeup, the development of OpSpecTR at LLNL by LLNL and NNSS personnel will be detailed first, followed by a write-up of the development of Vme-resolved simulaVons of the opacity-on-NIF experiment. Capsule backlight simulaVons, hohlraum simulaVons, and sample simulaVons from CASSIO are combined to produce the line of sight from the capsule to an effecVve OpSpec posiVon. Spectra are generated by post-processing these simulaVons from either Spect3D, a commercial software by Prism ComputaVonal Sciences, or FESTR (Finite Element Spectroscopic Transport of RadiaVon), a LANL code. While the simulaVons do not at this stage proceed late enough to include the worst of the backgrounds generated from the hohlraum experimentally and each post-processing simulaVon includes only one ray for each spectrometer channel, these efforts represent proof of concept for a new capability to complete Vme-resolved and Vmegated simulaVons for the complete line of sight of the complex opacity-on-NIF geometry. Future work will be discussed at the end of the report for both efforts.

42 ENGINEERING↗

XFOL FY25 Omega 3 pager [Slides]

The XFOL campaign is continuing to study radiation flow in stochastic media. Purpose: Simultaneously measure the ionization state of the background and inclusions of a binary stochastic media using the COAX/OUTI diagnostic. Motivation: Radflow is stochastic media is of wide, growing interest and COAX is a new powerful diagnostic that can characterize the radflow physics and validate codes, models, and their underlying assumptions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Roadmap for the exposé of radiation flows (Xflows) experiment on $\mathrm{NIF}$

Here, the goal of the Xflows experimental campaign is to study the radiation flow on the National Ignition Facility (NIF) reproducing the sensitivity of the temperature (±8 eV, ±23 μm) and density (±11 mg/cc) measurements of the COAX platform. This new platform will enable future astrophysical experiments involving supernova shock breakout, such as Radishock on OMEGA-60, and stochastic media (such as XFOL on OMEGA). Greater energy and larger physical scale on NIF will enable a greater travel distance of radiation flow, higher density, and more manufacturable foams and enable exploration of a greater range of radiation behavior than achievable in the prior OMEGA experiments. This publication will describe the baseline configuration for the Xflows experimental campaign and the roadmap to achieve its primary objectives.

47 OTHER INSTRUMENTATION↗

Detailed temperature diagnostic studies for Radishock and COAX experiments

Spectral diagnostics provide a powerful probe of high energy-density physics experiments. By shining an x-ray source on a target, absorption features can be used to determine accurate temperature profiles of that target material. Many studies produce a single temperature/density measurement by fitting these observed spectra. This paper demonstrates how, by leveraging detailed simulations, we can not only measure the average temperature and density, but the full density and temperature profiles. To do so, we must conduct a careful analysis of the uncertainties in the diagnostic measurement. Here we discuss the characteristics and associated uncertainties of the spectral diagnostic used in the COAX, Radishock and OuTi experiments, ultimately demonstrating how these detailed studies increase the potential of this powerful probe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Density measurements for the National Ignition Facility (NIF) opacity platform

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. Here, we present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.

47 OTHER INSTRUMENTATION↗

A temperature profile diagnostic for radiation waves on OMEGA-60

Predicting and matching radiation wave propagation with computational models has proven difficult. Information provided by experiments studying radiation flow has been limited when only radiation breakout is measured. We have developed the COAX (co-axial) diagnostic platform to provide spatial temperature profiles of a radiation wave through low density foams as a more detailed constraint for simulations. COAX uses a standard, laser-driven OMEGA-60 halfraum to drive radiation down a titanium-laden silicon oxide foam. Point-projection X-ray absorption spectroscopy perpendicular to the radiation flow measures the spatial profile of titanium ionization. The spectroscopic measurement utilizes a broadband capsule backlighter. Imaging and streak spectroscopy are used to characterize the size and spectrum of this source. Radiography provides an additional constraint by capturing the developing shock as the radiation flow becomes subsonic. The DANTE diagnostic is used to measure the halfraum temperature. Here, we provide a spectroscopic analysis of COAX data to determine temperature, and we describe experimental sources of uncertainty. The temperature is obtained by comparison to multi-temperature synthetic spectra post-processed from radiation-hydrodynamics simulations. Quantitative comparison between data and synthetic spectra generated from temperature profiles at relevant simulation times enable determination of a peak temperature of 114 ± 8 eV at 265 ± 22.4 μm from the halfraum. This represents an improvement over the temperature uncertainties of previous radiation flow experiments. Further refinements to the spectroscopic analysis could achieve ±4 eV. The combination between space-resolved spectroscopy and radiography enables us to determine the distance from the halfraum of both the radiation front and the shock front at the time of measurement. For the example shown in this paper the radiation front position is 600–630 μm at 3.43 ± 0.16 ns and the shock front position is 633 μm at 3.3 ± 0.24 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of computer vision for analysis of image datasets from high temperature plasma experiments

Great strides have been made in improving the quality of x-ray radiographs in high energy density plasma experiments, enabled in part by innovations in engineering and manufacturing of integrated circuits and materials. As a consequence, the radiographs of today are filled with a great deal of detail, but few of these features are extracted in a systematic way. Analysis techniques familiar to plasma physicists tend toward brittle 1D lineout or Fourier transform type analyses. The techniques applied to process our data have not kept pace with improvements in the quality of our data. Fortunately, the field of computer vision has a wealth of tools to offer, which have been widely used in industrial imaging and, more recently, adopted in biological imaging. We demonstrate the application of computer vision techniques to the analysis of x-ray radiographs from high energy density plasma experiments, as well as give a brief tutorial on the computer vision techniques themselves. These tools robustly extract 2D contours of shocks, boundaries of inhomogeneities, and secondary flows, thereby allowing for increased automation of analysis, as well as direct and quantitative comparisons with simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opacity: A window into High Energy Density Plasma Physics

Opacity is a fundamental property of matter and knowledge of it is required to understand the transport of radiation through a material. Exact knowledge of opacity is crucial in many fields such as astrophysics, which recently produced a white paper on the current state of astrophysical opacities [1], plasma physics, including inertial confinement fusion (ICF) and magnetic confinement fusion, high energy density physics (HEDP), the semiconductor industry [2] and stockpile stewardship. In industry, the accurate knowledge of the opacity of tin is important for extreme ultraviolet (EUV) lithography and the development of processors with smaller components. In astrophysics, Cepheid variable stars are used as “standard candles” for determining the distance to objects. Opacities of these stars are required to understand the relationship between their periodicity, luminosity and distance. Our sun is the most studied star and provides the basis of our understanding for other stars. Yet in significant ways the sun is poorly understood. In recent years, there has been a debate over the abundances of heavy elements (Z > 2) in the solar interior. Current solar atmosphere models [3] find a significantly lower abundance for C, N, and O compared to models used roughly a decade ago. Although solar evolution models have matured, a discrepancy still exists between spectroscopic solar models (which require opacities) with updated abundances, and solar properties inferred from helioseismology and neutrinos [4]. Despite its necessity, opacity is not solved, and is an open and active area of research needed for improving our understanding of plasma physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summaries of FY 2018 LANL experimental campaigns at the OMEGA and OMEGA-EP Laser Facilities

In FY 2018, Los Alamos National Laboratory carried out 21 shot days on the OMEGA and OMEGA-EP laser facilities in the areas of High Energy Density (HED) Science and Inertial Confinement Fusion (ICF). Our focus areas were on radiation flow, hydrodynamic turbulent mix and burn, and coupled Kelvin-Helmholtz (KH)/Richtmyer-Meshkov (RM) instability growth including in convergent geometry. We also had several focused shot days on transport properties in the kinetic regime. We continue to develop advanced diagnostics such as Neutron Imaging , and performed tests of a new imaging concept to be installed on NIF. We executed experiments in support of our double-shell campaign, and we began initial experiments using the new Revolver platform. Below is a summary of our campaigns, their motivation, and main results from this year.

47 OTHER INSTRUMENTATION↗

Development on the National Ignition Facility of a High Energy Density Opacity Platform

X-ray opacity is a crucial factor in all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in simulation codes for high-energy-density plasmas. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment for various mid-Z elements (Fe, Cr, Ni). These discrepancies raise doubts regarding the accuracy of the opacity models which are used in ICF and stewardship as well as in astrophysics. Therefore, a new experimental opacity platform has been developed on the National Ignition Facility (NIF), not only to verify the Z-machine experimental results, but also to extend the experiments to other temperatures and densities. Within the context of the national opacity strategy, the first NIF experiments were directed towards measuring the opacity of iron at a temperature of ~160 eV and an electron density of ~7xl021 cm-3(Anchor 1). The Z data agree with theory at these conditions, providing a reference point for validation of the NIF platform. Development shots on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule, and also a combined hohlraum, sample and laser drive able to produce iron plasmas at the desired conditions. Spectrometer qualification has been completed, albeit with additional improvements planned, and the first iron absorption spectra have now been obtained.

36 MATERIALS SCIENCE↗

Developing targets for radiation transport experiments at the Omega laser facility

Targets have been developed to measure supersonic radiation transport in aerogel foams using absorption spectroscopy. The target consists of an aerogel foam uniformly doped with either titanium or scandium inserted into an undoped aerogel foam package. This creates a localized doped foam region to provide spatial resolution for the measurement. Development and characterization of the foams is a key challenge in addition to machining and assembling the two foams so they mate without gaps. The foam package is inserted into a beryllium sleeve and mounted on a gold hohlraum. The target is mounted to a holder created using additive manufacturing and mounted on a stalk. As a result, the manufacturing of the components, along with assembly and metrology of the target are described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic physics modeling of transmission spectra of Sc-doped aerogel foams to support OMEGA experiments

We present synthetic transmission spectra generated with PrismSPECT utilizing both the ATBASE model and the Los Alamos opacity library (OPLIB) to evaluate whether an alternative choice in atomic data will impact modeling of experimental data from radiation transport experiments using Sc-doped aerogel foams (ScSi{sub 6}O{sub 12} at 75 mg/cm{sup 3} density). We have determined that in the 50-200 eV T{sub e} range there is a significant difference in the 1s-3p spectra, especially below 100 eV, and for T{sub e} = 200 eV above 5000 eV in photon energy. Examining synthetic spectra generated using OPLIB with 300 resolving power reveals spectral sensitivity to T{sub e} changes of ∼3 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗